Série PACi NX Elite Consola de Teto Inverter+ · R32
7.1 kW
Kit KIT-71PT3ZH48
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 6,8
Cooling capacity (Min) kW 2,2
Cooling capacity (Max) kW 9,0
EER (Nominal) (1) W/W 3,91
EER (Min) (1) W/W 2,69
EER (Max) (1) W/W 5,79
SEER/ηsc (2) % 7,2 A++
Pdesign (cooling) kW 6,8
Input power cooling (Nominal) kW 1,74
Input power cooling (Min) kW 0,38
Input power cooling (Max) kW 3,35
Annual energy consumption cooling (3) kWh/a 331
Heating capacity (Nominal) kW 8,0
Heating capacity (Min) kW 2,0
Heating capacity (Max) kW 9,0
COP (Nominal) (1) W/W 3,96
COP (Min) (1) W/W 3,16
COP (Max) (1) W/W 5,56
SCOP/ηsc (2) % 4,7 A++
Pdesign at -10°C kW 4,7
Input power heating (Nominal) kW 2,02
Input power heating (Min) kW 0,36
Input power heating (Max) kW 2,85
Annual energy consumption heating (3) kWh/a 1.400
Indoor unit S-6071PT3E
Indoor air flow (Hi) m³/min 21,0
Indoor air flow (Med) m³/min 18,0
Indoor air flow (Lo) m³/min 15,5
Moisture removal volume L/h 2,7
Indoor sound pressure (Med) (4) dB(A) 35
Indoor sound pressure (Lo) (4) dB(A) 30
Indoor sound power (Hi) dB(A) 57
Indoor sound power (Med) dB(A) 53
Indoor sound power (Lo) dB(A) 48
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1.275
Indoor dimension (Depth) mm 690
Indoor net weight kg 34
nanoe X Generator Mark 2
Outdoor unit U-71PZH4E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 2,95
Current in cooling (1p 230V / 3p 400) A 2,80
Current in cooling (1p 240V / 3p 415) A 2,70
Current in heating (1p 220V / 3p 380) A 3,15
Current in heating (1p 230V / 3p 400) A 3,00
Current in heating (1p 240V / 3p 415) A 2,90
Outdoor air flow (Cool) m³/min 62,0
Outdoor air flow (Heat) m³/min 66,0
Outdoor sound pressure (Cool -Hi) dB(A) 48
Outdoor sound pressure (Heat -Hi) dB(A) 50
Outdoor sound power (Cool -Hi) dB(A) 65
Outdoor sound power (Heat -Hi) dB(A) 67
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 66
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 60
Elevation difference (in/out) (7) m 15 / 30
Pipe length for additional gas m 30
Additional gas amount g/m 30
Refrigerant (R32) / CO2 Eq. kg / T 1,95 / 1,32
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +52
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

1) O EER e o COP são calculados com base na norma EN14511.
2) Para modelos abaixo dos 12 kW, o SEER e SCOP são calculados com base nos valores da diretiva UE/626/2011. Para modelos acima dos 12 kW, os valores do ηsc / ηsh são calculados com base na norma EN14825.
3) Configurações de fábrica.
4) O nível de pressão acústica das unidades mostra o valor medido num ponto situado a 1 metro à frente do corpo principal e 1 metro abaixo da unidade. A pressão acústica é medida de acordo com a especificação Eurovent 6/C/006-97.
5) Ligue o tubo do bocal do líquido (Ø6,35-Ø9,52) à lateral da tubagem de líquido na unidade interior.
6) Ligue o tubo do bocal do gás (Ø12,70-Ø15,88) à lateral da tubagem de gás na unidade interior.
7) Unidade exterior localizada mais abaixo / unidade exterior localizada mais acima.
8) Comprimento da tubagem até 30 m.

* Recomenda-se um fusível de 3 A para o interior.
** Os valores acima aplicam-se ao nanoe™ X OFF.