Série PACi NX Elite Cassete 4 vias 90x90 Inverter+ · R32

Cassete de 4 vias 90x90 Elite

O potente ventilador turbo e o sensor inteligente Econavi garantem uma elevada eficiência energética e o nanoe™ X, que vem equipado de série, proporciona um nível de qualidade do ar interior excecional.

A próxima geração de ar condicionado comercial

Especificações

Ver tudo
Série PACi NX Elite Cassete 4 vias 90x90 Inverter+ · R32
12.5 kW
Kit KIT-125PU3ZH45
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 12,5
Cooling capacity (Min) kW 3,2
Cooling capacity (Max) kW 14,0
EER (Nominal) (1) W/W 3,80
EER (Min) (1) W/W 3,08
EER (Max) (1) W/W 5,33
SEER/ηsc (2) % 304,3%
Pdesign (cooling) kW 12,5
Input power cooling (Nominal) kW 3,29
Input power cooling (Min) kW 0,60
Input power cooling (Max) kW 4,55
Annual energy consumption cooling (3) kWh/a
Heating capacity (Nominal) kW 14,0
Heating capacity (Min) kW 3,2
Heating capacity (Max) kW 16,0
COP (Nominal) (1) W/W 4,61
COP (Min) (1) W/W 3,37
COP (Max) (1) W/W 5,52
SCOP/ηsc (2) % 186,0%
Pdesign at -10°C kW 9,5
Input power heating (Nominal) kW 3,04
Input power heating (Min) kW 0,58
Input power heating (Max) kW 4,75
Annual energy consumption heating (3) kWh/a
Indoor unit S-1014PU3E
Indoor air flow (Hi) m³/min 37,0
Indoor air flow (Med) m³/min 27,0
Indoor air flow (Lo) m³/min 19,0
Moisture removal volume L/h 4,8
Indoor sound pressure (Med) (4) dB(A) 39
Indoor sound pressure (Lo) (4) dB(A) 33
Indoor sound power (Hi) dB(A) 61
Indoor sound power (Med) dB(A) 54
Indoor sound power (Lo) dB(A) 48
Indoor dimension (Height) mm 319
Indoor dimension (Width) mm 840
Indoor dimension (Depth) mm 840
Panel dimension (Height) mm 33,5
Panel dimension (Depth) mm 950
Indoor net weight kg 25
Panel net weight kg 5
nanoe X Generator Mark 1
Outdoor unit U-125PZH4E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 16,10
Current in cooling (1p 230V / 3p 400) A 15,40
Current in cooling (1p 240V / 3p 415) A 14,70
Current in heating (1p 220V / 3p 380) A 14,90
Current in heating (1p 230V / 3p 400) A 14,20
Current in heating (1p 240V / 3p 415) A 13,60
Outdoor air flow (Cool) m³/min 86,0
Outdoor air flow (Heat) m³/min 78,0
Outdoor sound pressure (Cool -Hi) dB(A) 55
Outdoor sound pressure (Heat -Hi) dB(A) 55
Outdoor sound power (Cool -Hi) dB(A) 73
Outdoor sound power (Heat -Hi) dB(A) 73
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 86
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 100
Elevation difference (in/out) (7) m 15 / 30
Pipe length for additional gas m 30
Additional gas amount g/m 40
Refrigerant (R32) / CO2 Eq. kg / T 3,00 / 2,03
Operating range (Cool - Min) °C -20 (8)
Operating range (Cool - Max) °C +52
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

1) O EER e o COP são calculados com base na norma EN14511.
2) Para modelos abaixo dos 12 kW, o SEER e SCOP são calculados com base nos valores da diretiva UE/626/2011. Para modelos acima dos 12 kW, os valores do ηsc / ηsh são calculados com base na norma EN14825.
3) Configurações de fábrica.
4) O nível de pressão acústica das unidades mostra o valor medido num ponto situado a 1,5 m abaixo da unidade. A pressão acústica é medida de acordo com a especificação Eurovent 6/C/006-97.
5) Ligue o tubo do bocal do líquido (Ø6,35-Ø9,52) à lateral da tubagem de líquido na unidade interior.
6) Ligue o tubo do bocal do gás (Ø12,70-Ø15,88) à lateral da tubagem de gás na unidade interior.
7) Unidade exterior localizada mais abaixo / unidade exterior localizada mais acima.
8) Comprimento da tubagem até 30 m.

* Recomenda-se um fusível de 3 A para o interior.
** Os valores acima aplicam-se ao nanoe™ X OFF.