Série PACi NX Elite Consola de Teto Inverter+ · R32

As unidades montadas no teto proporcionam uma distribuição grande e ampla de ar, o que é ideal para espaços grandes

Todas as unidades têm a mesma altura e profundidade para uma aparência uniforme em instalações mistas.

A próxima geração de ar condicionado comercial

Especificações

Ver tudo
Série PACi NX Elite Consola de Teto Inverter+ · R32
10.0 kW
Kit KIT-100PT3ZH48
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 9,5
Cooling capacity (Min) kW 3,1
Cooling capacity (Max) kW 12,5
EER (Nominal) (1) W/W 4,06
EER (Min) (1) W/W 3,29
EER (Max) (1) W/W 5,34
SEER/ηsc (2) % 7,2 A++
Pdesign (cooling) kW 9,5
Input power cooling (Nominal) kW 2,34
Input power cooling (Min) kW 0,58
Input power cooling (Max) kW 3,80
Annual energy consumption cooling (3) kWh/a 462
Heating capacity (Nominal) kW 11,2
Heating capacity (Min) kW 3,1
Heating capacity (Max) kW 14,0
COP (Nominal) (1) W/W 4,00
COP (Min) (1) W/W 3,54
COP (Max) (1) W/W 5,54
SCOP/ηsc (2) % 4,5 A+
Pdesign at -10°C kW 7,8
Input power heating (Nominal) kW 2,80
Input power heating (Min) kW 0,56
Input power heating (Max) kW 3,95
Annual energy consumption heating (3) kWh/a 2.427
Indoor unit S-1014PT3E
Indoor air flow (Hi) m³/min 30,0
Indoor air flow (Med) m³/min 25,0
Indoor air flow (Lo) m³/min 23,0
Moisture removal volume L/h 3,6
Indoor sound pressure (Med) (4) dB(A) 37
Indoor sound pressure (Lo) (4) dB(A) 34
Indoor sound power (Hi) dB(A) 60
Indoor sound power (Med) dB(A) 55
Indoor sound power (Lo) dB(A) 52
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1.590
Indoor dimension (Depth) mm 690
Indoor net weight kg 40
nanoe X Generator Mark 2
Outdoor unit U-100PZH4E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,60
Current in cooling (1p 230V / 3p 400) A 3,40
Current in cooling (1p 240V / 3p 415) A 3,25
Current in heating (1p 220V / 3p 380) A 3,75
Current in heating (1p 230V / 3p 400) A 3,55
Current in heating (1p 240V / 3p 415) A 3,40
Outdoor air flow (Cool) m³/min 76,0
Outdoor air flow (Heat) m³/min 70,0
Outdoor sound pressure (Cool -Hi) dB(A) 52
Outdoor sound pressure (Heat -Hi) dB(A) 52
Outdoor sound power (Cool -Hi) dB(A) 69
Outdoor sound power (Heat -Hi) dB(A) 69
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 82
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 100
Elevation difference (in/out) (7) m 15 / 30
Pipe length for additional gas m 30
Additional gas amount g/m 40
Refrigerant (R32) / CO2 Eq. kg / T 2,70 / 1,82
Operating range (Cool - Min) °C -20 (8)
Operating range (Cool - Max) °C +52
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

1) O EER e o COP são calculados com base na norma EN14511.
2) Para modelos abaixo dos 12 kW, o SEER e SCOP são calculados com base nos valores da diretiva UE/626/2011. Para modelos acima dos 12 kW, os valores do ηsc / ηsh são calculados com base na norma EN14825.
3) Configurações de fábrica.
4) O nível de pressão acústica das unidades mostra o valor medido num ponto situado a 1 metro à frente do corpo principal e 1 metro abaixo da unidade. A pressão acústica é medida de acordo com a especificação Eurovent 6/C/006-97.
5) Ligue o tubo do bocal do líquido (Ø6,35-Ø9,52) à lateral da tubagem de líquido na unidade interior.
6) Ligue o tubo do bocal do gás (Ø12,70-Ø15,88) à lateral da tubagem de gás na unidade interior.
7) Unidade exterior localizada mais abaixo / unidade exterior localizada mais acima.
8) Comprimento da tubagem até 30 m.

* Recomenda-se um fusível de 3 A para o interior.
** Os valores acima aplicam-se ao nanoe™ X OFF.

Produtos complementares