Ultrakompaktowe jednostki ścienne UZ Inverter.

UZ to seria kompaktowych i cichych jednostek ściennych typu split o doskonałych specyfikacjach.

Odkryj najnowszą generację klimatyzatorów

Klimatyzacja powiązana z przyszłością

Dane techniczne

Zobacz wszystko
Ultrakompaktowe jednostki UZ • Czynnik R32
5.00 kW
Kit KIT-UZ50-ZKE
Cooling capacity (Nominal) kW 5,00
Cooling capacity (Min) kW 0,98
Cooling capacity (Max) kW 5,40
EER (Nominal) (1) W/W 3,03
EER (Min) (1) W/W 3,92
EER (Max) (1) W/W 2,89
SEER (2) 6,50 A++
Pdesign (cooling) kW 5
Input power cooling (Nominal) kW 1,65
Input power cooling (Min) kW 0,25
Input power cooling (Max) kW 1,87
Annual energy consumption cooling (3) kWh/a 269
Heating capacity (Nominal) kW 5,40
Heating capacity (Min) kW 0,98
Heating capacity (Max) kW 7,40
Heating capacity at -7°C kW 4,52
COP (Nominal) (1) W/W 3,42
COP (Min) (1) W/W 4,67
COP (Max) (1) W/W 3,08
SCOP (2) 4,10 A+
Pdesign at -10°C kW 4
Input power heating (Nominal) kW 1,58
Input power heating (Min) kW 0,21
Input power heating (Max) kW 2,40
Annual energy consumption heating (3) kWh/a 1.366
Indoor unit CS-UZ50ZKE
Indoor power source V 230
Indoor recommended fuse A 16
Indoor connection indoor / outdoor mm² 4 x 2,5
Indoor air flow (Cool) m³/min 12,5
Indoor air flow (Heat) m³/min 13,2
Moisture removal volume L/h 2,8
Indoor sound pressure (Cool -Hi) (4) dB(A) 44
Indoor sound pressure (Cool -Hi) (4) dB(A) 44
Indoor sound pressure (Cool -Lo) (4) dB(A) 37
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 34
Indoor sound pressure (Heat -Hi) (4) dB(A) 44
Indoor sound pressure (Heat -Lo) (4) dB(A) 37
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 34
Indoor dimension (Height) mm 290
Indoor dimension (Width) mm 779
Indoor dimension (Depth) mm 209
Indoor net weight kg 8
Outdoor unit CU-UZ50ZKE
Outdoor air flow (Cool) m³/min 32,7
Outdoor air flow (Heat) m³/min 32,7
Outdoor sound pressure (Cool -Hi) (4) dB(A) 48
Outdoor sound pressure (Cool -Hi) (4) dB(A) 48
Outdoor sound pressure (Heat -Hi) (4) dB(A) 49
Outdoor dimension (Height) (5) mm 619
Outdoor dimension (Width) (5) mm 824
Outdoor dimension (Depth) (5) mm 299
Outdoor net weight kg 35
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 15
Elevation difference (in/out) (6) m 15
Pipe length for additional gas m 10
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,07 / 0,72
Operating range (Cool - Min) °C -10
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

(1) Wskaźniki EER i COP obliczone zgodnie z normą EN 14511.
(2) Etykieta energetyczna w skali od A+++ do D.
(3) Roczne zużycie energii obliczono zgodnie z rozporządzeniem (UE) 626/2011.
(4) Podane poziomy ciśnienia akustycznego dla jednostki wewnętrznej odnoszą się do wartości zmierzonych w odległości 1 m od czoła i na wysokości 0,8 m poniżej korpusu jednostki. Dla jednostki zewnętrznej – w odległości 1 m od czoła i 1 m od tyłu korpusu jednostki. Ciśnienie akustyczne mierzono zgodnie z normą JIS C 9612. Q-Lo: tryb cichy. Lo: najniższa nastawa prędkości wentylatora.
(5) Dodać 70 mm na przyłącze rurowe.
(6) Jednostka zewnętrzna zainstalowana wyżej niż jednostka wewnętrzna.