Ultrakompaktowe jednostki UZ • Czynnik R32

Ultrakompaktowe jednostki ścienne UZ Inverter.

UZ to seria kompaktowych i cichych jednostek ściennych typu split o doskonałych specyfikacjach.

Odkryj najnowszą generację klimatyzatorów

Klimatyzacja powiązana z przyszłością

Dane techniczne

Zobacz wszystko
Ultrakompaktowe jednostki UZ • Czynnik R32
3.3 kW
Kit KIT-UZ35-WKE
Cooling capacity (Nominal) kW 3,30
Cooling capacity (Min) kW 0,85
Cooling capacity (Max) kW 3,80
EER (Nominal) (1) W/W 3,20
EER (Min) (1) W/W 3,54
EER (Max) (1) W/W 3,06
SEER (2) 6,10 A++
Pdesign (cooling) kW 3,30
Input power cooling (Nominal) kW 1,03
Input power cooling (Min) kW 0,24
Input power cooling (Max) kW 1,24
Annual energy consumption cooling (3) kWh/a 189,00
Heating capacity (Nominal) kW 3,70
Heating capacity (Min) kW 0,80
Heating capacity (Max) kW 4,30
Heating capacity at -7°C kW 2,54
COP (Nominal) (1) W/W 3,70
COP (Min) (1) W/W 4,10
COP (Max) (1) W/W 3,44
SCOP (2) 4,10 A+
Pdesign at -10°C kW 2,40
Input power heating (Nominal) kW 1,00
Input power heating (Min) kW 0,20
Input power heating (Max) kW 1,25
Annual energy consumption heating (3) kWh/a 820
Indoor unit CS-UZ35WKE
Indoor power source V 230
Indoor recommended fuse A 16
Indoor connection indoor / outdoor mm² 4 x 1,5
Indoor air flow (Cool) m³/min 10,8
Indoor air flow (Heat) m³/min 11,3
Moisture removal volume L/h 1,9
Indoor sound pressure (Cool -Hi) (4) dB(A) 38
Indoor sound pressure (Cool -Hi) (4) dB(A) 38
Indoor sound pressure (Cool -Lo) (4) dB(A) 30
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 20
Indoor sound pressure (Heat -Hi) (4) dB(A) 38
Indoor sound pressure (Heat -Lo) (4) dB(A) 33
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 25
Indoor dimension (Height) mm 290
Indoor dimension (Width) mm 779
Indoor dimension (Depth) mm 209
Indoor net weight kg 8
Outdoor unit CU-UZ35WKE
Outdoor air flow (Cool) m³/min 31,1
Outdoor air flow (Heat) m³/min 31,1
Outdoor sound pressure (Cool -Hi) (4) dB(A) 48
Outdoor sound pressure (Cool -Hi) (4) dB(A) 48
Outdoor sound pressure (Heat -Hi) (4) dB(A) 50
Outdoor dimension (Height) (5) mm 542
Outdoor dimension (Width) (5) mm 780
Outdoor dimension (Depth) (5) mm 289
Outdoor net weight kg 25
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52)
Pipe length range m 3 ~ 15
Elevation difference (in/out) (6) m 15
Pipe length for additional gas m 7,5
Additional gas amount g/m 10
Refrigerant (R32) / CO2 Eq. kg / T 0,67 / 0,452
Operating range (Cool - Min) °C -10
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

(1) Wskaźniki EER i COP obliczone zgodnie z normą EN 14511.
(2) Etykieta energetyczna w skali od A+++ do D.
(3) Roczne zużycie energii obliczono zgodnie z rozporządzeniem (UE) 626/2011.
(4) Podane poziomy ciśnienia akustycznego dla jednostki wewnętrznej odnoszą się do wartości zmierzonych w odległości 1 m od czoła i na wysokości 0,8 m poniżej korpusu jednostki. Dla jednostki zewnętrznej – w odległości 1 m od czoła i 1 m od tyłu korpusu jednostki. Ciśnienie akustyczne mierzono zgodnie z normą JIS C 9612. Q-Lo: tryb cichy. Lo: najniższa nastawa prędkości wentylatora.
(5) Dodać 70 mm na przyłącze rurowe.
(6) Jednostka zewnętrzna zainstalowana wyżej niż jednostka wewnętrzna.