Ultrakompaktowe jednostki BZ · Czynnik R32

Ultrakompaktowe jednostki ścienne BZ Inverter

BZ to seria kompaktowych i cichych jednostek ściennych typu split o doskonałych specyfikacjach, wyposażonych w filtr PM2,5.

Odkryj najnowszą generację klimatyzatorów

Klimatyzacja powiązana z przyszłością

Dane techniczne

Zobacz wszystko
Ultrakompaktowe jednostki BZ · Czynnik R32
6.00 kW
Kit KIT-BZ60-XKE
Cooling capacity (Nominal) kW 6,00
Cooling capacity (Min) kW 0,98
Cooling capacity (Max) kW 6,50
EER (Nominal) (1) W/W 3,03
EER (Min) (1) W/W 3,92
EER (Max) (1) W/W 2,83
SEER (2) 6,30 A++
Pdesign (cooling) kW 6,00
Input power cooling (Nominal) kW 1,98
Input power cooling (Min) kW 0,25
Input power cooling (Max) kW 2,30
Annual energy consumption cooling (3) kWh/a 333
Heating capacity (Nominal) kW 6,80
Heating capacity (Min) kW 0,98
Heating capacity (Max) kW 8,00
Heating capacity at -7°C kW 5,10
COP (Nominal) (1) W/W 3,16
COP (Min) (1) W/W 4,26
COP (Max) (1) W/W 3,02
SCOP (2) 4,00 A+
Pdesign at -10°C kW 4,40
Input power heating (Nominal) kW 2,15
Input power heating (Min) kW 0,23
Input power heating (Max) kW 2,65
Annual energy consumption heating (3) kWh/a 1.54
Indoor unit CS-BZ60XKE
Indoor power source V 230
Indoor recommended fuse A 20
Indoor connection indoor / outdoor mm² 4 x 2,5
Indoor air flow (Cool) m³/min 12,7
Indoor air flow (Heat) m³/min 13,6
Moisture removal volume L/h 3,3
Indoor sound pressure (Cool -Hi) (4) dB(A) 45
Indoor sound pressure (Cool -Hi) (4) dB(A) 45
Indoor sound pressure (Cool -Lo) (4) dB(A) 37
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 34
Indoor sound pressure (Heat -Hi) (4) dB(A) 45
Indoor sound pressure (Heat -Lo) (4) dB(A) 37
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 34
Indoor dimension (Height) mm 290
Indoor dimension (Width) mm 779
Indoor dimension (Depth) mm 209
Indoor net weight kg 9
Outdoor unit CU-BZ60XKE
Outdoor air flow (Cool) m³/min 42,6
Outdoor air flow (Heat) m³/min 41,5
Outdoor sound pressure (Cool -Hi) (4) dB(A) 50
Outdoor sound pressure (Cool -Hi) (4) dB(A) 50
Outdoor sound pressure (Heat -Hi) (4) dB(A) 50
Outdoor dimension (Height) (5) mm 695
Outdoor dimension (Width) (5) mm 875
Outdoor dimension (Depth) (5) mm 320
Outdoor net weight kg 43
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 30
Elevation difference (in/out) (6) m 15
Pipe length for additional gas m 7,5
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,11 / 0,75
Operating range (Cool - Min) °C -10
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C 43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C 24

1) Wskaźniki EER i COP obliczone zgodnie z normą EN 14511.
2) Etykieta energetyczna w skali od A+++ do D.
3) Roczne zużycie energii obliczone zgodnie z rozporządzeniem (UE) 626/2011.
4) Podane poziomy ciśnienia akustycznego dla jednostki wewnętrznej odnoszą się do wartości zmierzonych w odległości 1 m i na wysokości 0,8 m poniżej korpusu jednostki. Dla jednostki zewnętrznej – w odległości 1 m od czoła i 1 m od tyłu korpusu jednostki. Ciśnienie akustyczne mierzono zgodnie z normą JIS C 9612. Q-Lo: tryb cichy. Lo: Najniższa nastawa prędkości wentylatora.
5) Dodać 70 mm na przyłącze rurowe.