Veggmontert PACi Standard • R32

Disse veggmonterte enhetene med stilig matt farge er fleksible og passer både for studioer, treningssentre, rom med stor takhøyde og serverrom.

Den kompakte utformingen og flate fronten gir diskré installasjon, selv i små rom.

Spesifikasjoner

Se alle
Veggmontert PACi Standard • R32 1-FASE 3-FASE
6.1 kW 7.1 kW 9.0 kW 9.0 kW
Kit KIT-60PK2Z5 KIT-71PK2Z5 KIT-100PK2Z5 KIT-100PK2Z8
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 6,1 7,1 9,0 9,0
Cooling capacity (Min) kW 2,0 2,0 3,0 3,0
Cooling capacity (Max) kW 7,1 7,7 9,7 9,7
EER (Nominal) (1) W/W 3,79 3,21 3,47 3,47
EER (Min) (1) W/W 5,36 5,36
EER (Max) (1) W/W 3,13 3,13 
SEER (2) 6,8 A++ 6,4 A++ 6,5 A++ 6,5 A++
Pdesign (cooling) kW 6,1 7,1 9,0 9,0
Input power cooling (Nominal) kW 1,61 2,21 2,59 2,59
Annual energy consumption cooling (3) kWh/a 314 388 485 485
Input power cooling (Min) kW 0,56 0,56
Input power cooling (Max) kW 3,10 3,10
Annual energy consumption cooling (3) kWh/a 314 388 485 485
Heating capacity (Nominal) kW 6,1 7,1 9,0 9,0
Heating capacity (Min) kW 1,8 1,8 3,0 3,0
Heating capacity (Max) kW 7,0 8,1 10,5 10,5
COP (Nominal) (1) W/W 4,80 4,41 3,93 3,93
COP (Min) (1) W/W 5,36 5,36
COP (Max) (1) W/W 3,56 3,56 
SCOP (2) 4,7 A++ 4,6 A++ 3,9 A 3,9 A
Pdesign at -10°C kW 6,0 6,0 9,0 9,0
Input power heating (Nominal) kW 1,27 1,61 2,29 2,29
Input power heating (Min) kW 0,56 0,56
Input power heating (Max) kW 2,95 2,95
Annual energy consumption heating (3) kWh/a 1787 1826 3231 3231
Indoor unit S-60PK2E5B S-71PK2E5B S-100PK2E5B S-100PK2E5B
Indoor air flow (Hi) m³/min 20,0 20,0 22,0 22,0
Indoor air flow (Med) m³/min 18,0 18,0 18,5 18,5
Indoor air flow (Lo) m³/min 15,0 15,0 15,0 15,0
Moisture removal volume L/h 2,0 3,0 4,3 4,3
Indoor sound pressure (Med) (4) dB(A) 44 44 45 45
Indoor sound pressure (Lo) (4) dB(A) 40 40 41 41
Indoor sound power (Hi) dB(A) 63 63 65 65
Indoor sound power (Med) dB(A) 60 60 61 61
Indoor sound power (Lo) dB(A) 56 56 57 57
Indoor dimension (Height) mm 302 302 302 302
Indoor dimension (Width) mm 1120 1120 1120 1120
Indoor dimension (Depth) mm 236 236 236 236
Indoor net weight kg 14 14 14 14
Outdoor unit U-60PZ2E5 U-71PZ2E5 U-100PZ2E5 U-100PZ2E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 7,85 10,70 12,10 4,10
Current in cooling (1p 230V / 3p 400) A 7,50 10,20 11,50 3,90
Current in cooling (1p 240V / 3p 415) A 7,20 9,85 11,10 3,75
Current in heating (1p 220V / 3p 380) A 6,10 7,85 10,60 3,60
Current in heating (1p 230V / 3p 400) A 5,85 7,50 10,20 3,45
Current in heating (1p 240V / 3p 415) A 5,60 7,20 9,70 3,30
Outdoor air flow (Cool) m³/min 40 50 76 76
Outdoor air flow (Heat) m³/min 45 45 70 70
Outdoor sound pressure (Cool -Hi) dB(A) 46 49 52 52
Outdoor sound pressure (Heat -Hi) dB(A) 48 49 52 52
Outdoor sound power (Cool -Hi) dB(A) 65 69 70 70
Outdoor sound power (Heat -Hi) dB(A) 68 69 70 70
Outdoor dimension (Height) mm 695 695 996 996
Outdoor dimension (Width) mm 875 875 980 980
Outdoor dimension (Depth) mm 320 320 370 370
Outdoor net weight kg 44 44 90 90
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50
Elevation difference (in/out) (5) m 30 30 30 30
Pipe length for additional gas m 30 30 30 30
Additional gas amount g/m 35 35 45 45
Refrigerant (R32) / CO2 Eq. kg / T 1,45 / 0,979 1,45 / 0,979 2,60 / 1,755 2,60 / 1,755
Operating range (Cool - Min) °C -10 -10 -10 -10
Operating range (Cool - Max) °C 43 43 43 43
Operating range (Heat - Min) °C -15 -15 -15 -15
Operating range (Heat - Max) °C 24 24 24 24

(1) EER- og COP-beregning er basert på EN 14511.
(2) Energimerking fra A+++ til D. For modeller under 12 kW er SEER og SCOP beregnet ut fra verdiene i EU/626/2011. For modeller over 12 kW er SEER og SCOP beregnet ut fra verdiene i EU/2281/2016.
(3) Det årlige energiforbruket beregnes i henhold til EU/626/2011.
(4) Lydtrykket til enhetene viser verdien målt 1 m foran hoveddelen og 1 m under enheten. Lydtrykket er målt i samsvar med Eurovent 6/C/006-97-spesifikasjonene.
(5) Når utedelen installeres i en høyere posisjon enn innedelen.
* Anbefalt sikring for innedel 3 A.

Kompletterende produkter