Veggmontert PACi Elite • R32

Forrige kapasitet Neste kapasitet

Enhetene i denne serien gir mange flere bruksområder, som studioer, treningssentre, rom med stor takhøyde og serverrom.

Den kompakte utformingen og flate fronten gir diskré installasjon, selv i små rom.

Spesifikasjoner

Se alle
Veggmontert PACi Elite • R32
3.6 kW
Kit KIT-36PK2ZH5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 3,6
Cooling capacity (Min) kW 1,5
Cooling capacity (Max) kW 4,0
EER (Nominal) (1) W/W 4,90
SEER (2) 8,0 A++
Pdesign (cooling) kW 3,6
Input power cooling (Nominal) kW 0,74
Annual energy consumption cooling (3) kWh/a 157
Annual energy consumption cooling (3) kWh/a 157
Heating capacity (Nominal) kW 4,0
Heating capacity (Min) kW 1,5
Heating capacity (Max) kW 5,0
COP (Nominal) (1) W/W 4,94
SCOP (2) 4,9 A++
Pdesign at -10°C kW 3,6
Input power heating (Nominal) kW 0,81
Annual energy consumption heating (3) kWh/a 1029
Indoor unit S-36PK2E5B
Indoor air flow (Hi) m³/min 13,0
Indoor air flow (Med) m³/min 11,0
Indoor air flow (Lo) m³/min 9,0
Indoor sound pressure (Med) (4) dB(A) 31
Indoor sound pressure (Lo) (4) dB(A) 27
Indoor dimension (Height) mm 302
Indoor dimension (Width) mm 1120
Indoor dimension (Depth) mm 236
Indoor net weight kg 13
Outdoor unit U-36PZH2E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 3,55
Current in cooling (1p 230V / 3p 400) A 3,40
Current in cooling (1p 240V / 3p 415) A 3,25
Current in heating (1p 220V / 3p 380) A 3,95
Current in heating (1p 230V / 3p 400) A 3,75
Current in heating (1p 240V / 3p 415) A 3,60
Outdoor air flow (Cool) m³/min 40
Outdoor air flow (Heat) m³/min 40
Outdoor sound pressure (Cool -Hi) dB(A) 43
Outdoor sound pressure (Heat -Hi) dB(A) 44
Outdoor sound power (Cool -Hi) dB(A) 62
Outdoor sound power (Heat -Hi) dB(A) 64
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 43
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 20
Refrigerant (R32) / CO2 Eq. kg / T 1,15 / 0,776
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C 46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C 24

(1) EER- og COP-beregning er basert på EN 14511.
(2) Energimerking fra A+++ til D. For modeller under 12 kW er SEER og SCOP beregnet ut fra verdiene i EU/626/2011. For modeller over 12 kW er SEER og SCOP beregnet ut fra verdiene i EU/2281/2016.
(3) Det årlige energiforbruket beregnes i henhold til EU/626/2011.
(4) Lydtrykket til enhetene viser verdien målt 1 m foran hoveddelen og 1 m under enheten. Lydtrykket er målt i samsvar med Eurovent 6/C/006-97-spesifikasjonene.
(5) Når utedelen installeres i en høyere posisjon enn innedelen.
(6) For modellene 100 ~ 140PZH2E5(8) er drift i datarom mulig ned til -20 °C med en rørlengde på 30 m eller mindre.
* Anbefalt sikring for innedel 3 A.