Models
Wall-mounted UZ super-compact Inverter.
UZ is a compact and quiet wall split series with high standards specs.
- Compact design with 779 mm
- Dust Collection Filter
- Very Quiet
- Aerowings to control air draft direction
- High energy savings
- Cooling even at -10 °C
- Optional internet and voice control
Discover the latest generation of air conditioning system



Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost, creating a clean air, free of viruses, bacteria, pollen and odours.
A range of products designed for you
From the smaller 1X1 to the more complete 5x1 solutions, it doesn’t matter which your need is. Panasonic can offers you the best solution to get the best clima in your home.
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience during the whole year.
Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost, creating a clean air, free of viruses, bacteria, pollen and odours.
A range of products designed for you
From the smaller 1X1 to the more complete 5x1 solutions, it doesn’t matter which your need is. Panasonic can offers you the best solution to get the best clima in your home.
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience during the whole year.
The air conditioning connects with the future

Specifications
UZ super-compact • R32 | SINGLE PHASE | ||||
---|---|---|---|---|---|
5 kW | 2.5 kW | 3.3 kW | |||
Cooling capacity (Min) | kW | 0,98 | 0,85 | 0,85 | |
Input power heating (Min) | kW | 0,21 | 0,19 | 0,20 | |
COP (Max) (1) | W/W | 3,08 | 3,47 | 3,44 | |
COP (Min) (1) | W/W | 4,67 | 4,21 | 4,10 | |
Heating capacity (Max) | kW | 7,40 | 3,50 | 4,30 | |
Heating capacity (Min) | kW | 0,98 | 0,80 | 0,80 | |
Input power cooling (Max) | kW | 1,81 | 0,90 | 1,24 | |
Input power cooling (Min) | kW | 0,25 | 0,21 | 0,24 | |
EER (Max) (1) | W/W | 2,93 | 3,33 | 3,06 | |
EER (Min) (1) | W/W | 3,92 | 4,05 | 3,54 | |
Cooling capacity (Max) | kW | 5,30 | 3,00 | 3,80 | |
Input power heating (Max) | kW | 2,40 | 1,01 | 1,25 | |
Operating range (Heat - Max) | °C | +24 | +24 | +24 | |
Operating range (Heat - Min) | °C | -15 | -15 | -15 | |
Operating range (Cool - Max) | °C | +43 | +43 | +43 | |
Elevation difference (in/out) (6) | m | 15 | 15 | 15 | |
Outdoor dimension (Depth) (5) | mm | 299 | 289 | 289 | |
Outdoor dimension (Width) (5) | mm | 824 | 780 | 780 | |
Outdoor dimension (Height) (5) | mm | 619 | 542 | 542 | |
Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 49 | 49 | 50 | |
Outdoor unit | CU-UZ50WKE | CU-UZ25WKE | CU-UZ35WKE | ||
Outdoor air flow (Heat) | m³/min | 32,7 | 30,4 | 31,1 | |
Outdoor air flow (Cool) | m³/min | 32,7 | 30,4 | 31,1 | |
Indoor unit | CS-UZ50WKE | CS-UZ25WKE | CS-UZ35WKE | ||
Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 34 | 24 | 25 | |
Indoor sound pressure (Heat -Lo) (4) | dB(A) | 37 | 27 | 33 | |
Indoor sound pressure (Heat -Hi) (4) | dB(A) | 44 | 37 | 38 | |
Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 34 | 20 | 20 | |
Indoor sound pressure (Cool -Lo) (4) | dB(A) | 37 | 26 | 30 | |
Moisture removal volume | L/h | 2,8 | 1,5 | 1,9 | |
Indoor air flow (Heat) | m³/min | 13,2 | 11,1 | 11,3 | |
Indoor air flow (Cool) | m³/min | 12,5 | 10,5 | 10,8 | |
Indoor connection indoor / outdoor | mm² | 4 x 2,5 | 4 x 1,5 | 4 x 1,5 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 44 | 37 | 38 | |
SCOP (2) | 4,10 A+ | 4,10 A+ | 4,10 A+ | ||
Annual energy consumption heating (3) | kWh/a | 1366 | 649 | 820 | |
Annual energy consumption cooling (3) | kWh/a | 269,00 | 141,00 | 189,00 | |
Input power cooling (Nominal) | kW | 1,65 | 0,68 | 1,03 | |
Pdesign (cooling) | kW | 5,00 | 2,50 | 3,30 | |
SEER (2) | 6,50 A++ | 6,20 A++ | 6,10 A++ | ||
Outdoor net weight | kg | 36 | 24 | 25 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 48 | 48 | 48 | |
Indoor net weight | kg | 8 | 8 | 8 | |
Indoor dimension (Height) | mm | 290 | 290 | 290 | |
Pdesign at -10°C | kW | 4,00 | 1,90 | 2,40 | |
Indoor power source | V | 230 | 230 | 230 | |
Pipe length range | m | 3 ~ 15 | 3 ~ 15 | 3 ~ 15 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,14 / 0,770 | 0,54 / 0,365 | 0,67 / 0,452 | |
Kit | KIT-UZ50-WKE | KIT-UZ25-WKE | KIT-UZ35-WKE | ||
Additional gas amount | g/m | 15 | 10 | 10 | |
Pipe length for additional gas | m | 7,5 | 7,5 | 7,5 | |
Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | 3/8 (9,52) | 3/8 (9,52) | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) | |
Indoor dimension (Depth) | mm | 209 | 209 | 209 | |
Indoor dimension (Width) | mm | 779 | 779 | 779 | |
Indoor recommended fuse | A | 16 | 16 | 16 | |
Heating capacity at -7°C | kW | 4,52 | 2,08 | 2,54 | |
EER (Nominal) (1) | W/W | 3,03 | 3,68 | 3,20 | |
COP (Nominal) (1) | W/W | 3,42 | 4,05 | 3,70 | |
Heating capacity (Nominal) | kW | 5,40 | 3,00 | 3,70 | |
Cooling capacity (Nominal) | kW | 5,00 | 2,50 | 3,30 | |
Operating range (Cool - Min) | °C | -10 | -10 | -10 | |
Input power heating (Nominal) | kW | 1,58 | 0,74 | 1,00 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.