T-CAP All in One M Series 1 phase - 3 phase · R290

T-CAP All in One M Series 1 phase - 3 phase · R290

Aquarea M Series, the latest generation of Aquarea air to water heat pumps with R290

Aquarea T‑CAP M Series delivers a revolution in the design, performance, connectivity, and sustainability.
The solution is suitable for both new buildings and retrofits, as it offers a sustainable alternative to traditional fossil fuel heating systems and it can be easily integrated with existing water system such as fan coils, floor heating or domestic hot water tanks.

Specifications

See all
T-CAP All in One M Series 1 phase - 3 phase · R290 SINGLE PHASE THREE PHASE
9 kW 12 kW 9 kW 12 kW 16 kW
Outdoor unit WH-WXG09ME5 WH-WXG12ME5 WH-WXG09ME8 WH-WXG12ME8 WH-WXG16ME8
Heating capacity (A +7°C, W 35°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A +7°C, W 35°C) 5,23 5,06 5,23 5,06 4,89
Heating capacity (A +7°C, W 55°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A +7°C, W 55°C) 3,24 3,23 3,24 3,23 3,20
Heating capacity (A +2°C, W 35°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A +2°C, W 35°C) 3,81 3,54 3,81 3,54 3,30
Heating capacity (A +2°C, W 55°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A +2°C, W 55°C) 2,54 2,42 2,54 2,42 2,37
Heating capacity (A -7°C, W 35°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A -7°C, W 35°C) 3,45 3,00 3,45 3,00 2,53
Heating capacity (A -7°C, W 55°C) kW 9,00 12,00 9,00 12,00 16,00
COP (A -7°C, W 55°C) 2,35 2,17 2,35 2,17 1,97
Cooling capacity (A 35°C, W 7°C) kW 9,00 9,00 9,00 9,00 9,00
EER (A 35°C, W 7°C) 3,61 3,61 3,61 3,61 3,61
Cooling capacity (A 35°C, W 18°C) kW 9,00 12,00 9,00 12,00 16,00
EER (A 35°C, W 18°C) 5,26 5,26 5,26 5,26 5,26
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,96 / 3,57 5,00 / 3,46 4,96 / 3,57 5,00 / 3,46 4,20 / 3,31
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 195 / 140 197 / 135 195 / 140 197 / 135 168 / 129
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34 5,88 / 4,09
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 256 / 171 256 / 171 256 / 171 256 / 171 232/160
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26 3,83 / 3,20
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 169/127 169/127 169/127 169/127 150 / 125
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A++ A++ / A++ A++ / A++
Outdoor dimension (Height) mm 1.520 1.520 1.520 1.520 1.520
Outdoor dimension (Width) mm 1.200 1.200 1.200 1.200 1.200
Outdoor dimension (Depth) mm 430 430 430 430 430
Outdoor net weight kg 161 161 161 161 165
A class pump (Number of speeds) Variable speed Variable speed Variable speed Variable speed Variable speed
A class pump (Input power Min) W 30 30 30 30 30
A class pump (Input power Max) W 175 175 175 175 175
Heating water flow (∆T=5 K. 35°C) L/min 25,8 34,4 25,8 34,4 45,9
Operation range - outdoor temperature (Heat) °C -28 ~ +35 -28 ~ +35 -28 ~ +35 -28 ~ +35 -28 ~ +35
Operation range - outdoor temperature (Cool) °C +10 to +43 +10 to +43 +10 to +43 +10 to +43 +10 to +43
Water outlet (Heat) °C 25 to 75 25 to 75 25 to 75 25 to 75 25 to 75
Water outlet (Cool) °C 5 to 20 5 to 20 5 to 20 5 to 20 5 to 20
Indoor dimension (Height) mm 1.642 1.642 1.642 1.642 1.642
Indoor dimension (Width) mm 599 599 599 599 599
Indoor dimension (Depth) mm 602 602 602 602 602
Indoor net weight kg 89 89 89 89 89
Water volume L 185 185 185 185 185
Maximum water temperature °C 65 65 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
Elevation difference (in/out) m 30 30 30 30 30
Tapping profile according EN16147 L L L L L
DHW tank ERP average climate η ηwh % 123 123 123 123 117
DHW tank ERP warm climate η ηwh % 132 132 132 132 128
DHW tank ERP cold climate η ηwh % 88 88 88 88 84

(1) Scale from A+++ to D.
(2) Sound power level in accordance to EN12102 under conditions of the EN14825.
(3) WH-WXG models are hermetically sealed.
(4) Check local regulations.
(5) Scale from A+ to F.
* EER and COP classification is at 230V only in accordance with EU directive 2003/32/EC.
** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.