Models
T-CAP All in One M Series 1 phase - 3 phase · R290
Aquarea M Series, the latest generation of Aquarea air to water heat pumps with R290
Aquarea T‑CAP M Series delivers a revolution in the design, performance, connectivity, and sustainability.
The solution is suitable for both new buildings and retrofits, as it offers a sustainable alternative to traditional fossil fuel heating systems and it can be easily integrated with existing water system such as fan coils, floor heating or domestic hot water tanks.
- Up to 75°C water outlet down to -15°C outdoor
- Quiet operation: Only 29dB(A) sound pressure at 5 m*
- Reliable outdoor units with Panasonic compressor, operating down to -28°C outdoor
- T‑CAP technology: Keeping heating capacity down to -20°C
- Panasonic Comfort Cloud App and Aquarea Service Cloud included
- 2 CN-CNT connectivity ports
- Hydraulic connection between indoor and outdoor
- Maintenance free Inox stainless 185L tank
- All in One 599 x 602mm footprint reduces required installation space indoors
- No buffer tank required, reducing space, cost and installation time
- U-Vacua™ insulation panel for higher tank efficiency
- Also available with built-in impressed current anode (AN version)
* Sound pressure calculation for WH-WXG12ME5, free standing, A +7°C, W 35°C in Quite mode 3.
Specifications
T-CAP All in One M Series 1 phase - 3 phase · R290 | SINGLE PHASE | THREE PHASE | |||||
---|---|---|---|---|---|---|---|
9 kW | 12 kW | 9 kW | 12 kW | 16 kW | |||
Outdoor unit | WH-WXG09ME5 | WH-WXG12ME5 | WH-WXG09ME8 | WH-WXG12ME8 | WH-WXG16ME8 | ||
Heating capacity (A +7°C, W 35°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A +7°C, W 35°C) | 5,23 | 5,06 | 5,23 | 5,06 | 4,89 | ||
Heating capacity (A +7°C, W 55°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A +7°C, W 55°C) | 3,24 | 3,23 | 3,24 | 3,23 | 3,20 | ||
Heating capacity (A +2°C, W 35°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A +2°C, W 35°C) | 3,81 | 3,54 | 3,81 | 3,54 | 3,30 | ||
Heating capacity (A +2°C, W 55°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A +2°C, W 55°C) | 2,54 | 2,42 | 2,54 | 2,42 | 2,37 | ||
Heating capacity (A -7°C, W 35°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A -7°C, W 35°C) | 3,45 | 3,00 | 3,45 | 3,00 | 2,53 | ||
Heating capacity (A -7°C, W 55°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
COP (A -7°C, W 55°C) | 2,35 | 2,17 | 2,35 | 2,17 | 1,97 | ||
Cooling capacity (A 35°C, W 7°C) | kW | 9,00 | 9,00 | 9,00 | 9,00 | 9,00 | |
EER (A 35°C, W 7°C) | 3,61 | 3,61 | 3,61 | 3,61 | 3,61 | ||
Cooling capacity (A 35°C, W 18°C) | kW | 9,00 | 12,00 | 9,00 | 12,00 | 16,00 | |
EER (A 35°C, W 18°C) | 5,26 | 5,26 | 5,26 | 5,26 | 5,26 | ||
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,96 / 3,57 | 5,00 / 3,46 | 4,96 / 3,57 | 5,00 / 3,46 | 4,20 / 3,31 | |
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 195 / 140 | 197 / 135 | 195 / 140 | 197 / 135 | 168 / 129 | |
Heating average climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | A+++ / A++ | A+++ / A++ | A+++ / A++ | A+++ / A++ | |
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 6,47 / 4,34 | 6,47 / 4,34 | 6,47 / 4,34 | 6,47 / 4,34 | 5,88 / 4,09 | |
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 256 / 171 | 256 / 171 | 256 / 171 | 256 / 171 | 232/160 | |
Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | |
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,31 / 3,26 | 4,31 / 3,26 | 4,31 / 3,26 | 4,31 / 3,26 | 3,83 / 3,20 | |
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 169/127 | 169/127 | 169/127 | 169/127 | 150 / 125 | |
Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A++ | A++ / A++ | A++ / A++ | A++ / A++ | A++ / A++ | |
Outdoor dimension (Height) | mm | 1.520 | 1.520 | 1.520 | 1.520 | 1.520 | |
Outdoor dimension (Width) | mm | 1.200 | 1.200 | 1.200 | 1.200 | 1.200 | |
Outdoor dimension (Depth) | mm | 430 | 430 | 430 | 430 | 430 | |
Outdoor net weight | kg | 161 | 161 | 161 | 161 | 165 | |
A class pump (Number of speeds) | Variable speed | Variable speed | Variable speed | Variable speed | Variable speed | ||
A class pump (Input power Min) | W | 30 | 30 | 30 | 30 | 30 | |
A class pump (Input power Max) | W | 175 | 175 | 175 | 175 | 175 | |
Heating water flow (∆T=5 K. 35°C) | L/min | 25,8 | 34,4 | 25,8 | 34,4 | 45,9 | |
Operation range - outdoor temperature (Heat) | °C | -28 ~ +35 | -28 ~ +35 | -28 ~ +35 | -28 ~ +35 | -28 ~ +35 | |
Operation range - outdoor temperature (Cool) | °C | +10 to +43 | +10 to +43 | +10 to +43 | +10 to +43 | +10 to +43 | |
Water outlet (Heat) | °C | 25 to 75 | 25 to 75 | 25 to 75 | 25 to 75 | 25 to 75 | |
Water outlet (Cool) | °C | 5 to 20 | 5 to 20 | 5 to 20 | 5 to 20 | 5 to 20 | |
Indoor dimension (Height) | mm | 1.642 | 1.642 | 1.642 | 1.642 | 1.642 | |
Indoor dimension (Width) | mm | 599 | 599 | 599 | 599 | 599 | |
Indoor dimension (Depth) | mm | 602 | 602 | 602 | 602 | 602 | |
Indoor net weight | kg | 89 | 89 | 89 | 89 | 89 | |
Water volume | L | 185 | 185 | 185 | 185 | 185 | |
Maximum water temperature | °C | 65 | 65 | 65 | 65 | 65 | |
Material inside tank | Stainless steel | Stainless steel | Stainless steel | Stainless steel | Stainless steel | ||
Elevation difference (in/out) | m | 30 | 30 | 30 | 30 | 30 | |
Tapping profile according EN16147 | L | L | L | L | L | ||
DHW tank ERP average climate η | ηwh % | 123 | 123 | 123 | 123 | 117 | |
DHW tank ERP warm climate η | ηwh % | 132 | 132 | 132 | 132 | 128 | |
DHW tank ERP cold climate η | ηwh % | 88 | 88 | 88 | 88 | 84 |
(1) Scale from A+++ to D.
(2) Sound power level in accordance to EN12102 under conditions of the EN14825.
(3) WH-WXG models are hermetically sealed.
(4) Check local regulations.
(5) Scale from A+ to F.
* EER and COP classification is at 230V only in accordance with EU directive 2003/32/EC.
** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.