K Generation 1 phase - 3 phase · R32

Aquarea T-CAP Bi-Bloc K Generation

A revolution in design, efficiency, connectivity and sustainability.
Aquarea K Generation is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance.
Aquarea T-CAP is the range for retrofit and new builds, keeping Total Capacity even at extremely cold ambient.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Owning an Aquarea?

Specifications

See all
K Generation 1 phase - 3 phase · R32 SINGLE PHASE THREE PHASE
9 kW 12 kW 9 kW 12 kW
Kit 3kW electric heater KIT-WXC09K3E5 KIT-WXC09K3E8
Kit 6kW electric heater KIT-WXC09K6E5 KIT-WXC12K6E5
Kit 9kW electric heater KIT-WXC09K9E8 KIT-WXC12K9E8
Heating capacity (A +7°C, W 35°C) kW 9,00 12,10 9,00 12,10
COP (A +7°C, W 35°C) 5,03 4,84 5,03 4,84
Heating capacity (A +7°C, W 55°C) kW 9,00 12,10 9,00 12,10
COP (A +7°C, W 55°C) 3,07 3,04 3,07 3,04
Heating capacity (A +2°C, W 35°C) kW 9,00 12,00 9,00 12,00
COP (A +2°C, W 35°C) 3,69 3,44 3,69 3,44
Heating capacity (A +2°C, W 55°C) kW 9,00 12,00 9,00 12,00
COP (A +2°C, W 55°C) 2,31 2,29 2,31 2,29
Heating capacity (A -7°C, W 35°C) kW 9,00 12,00 9,00 12,00
COP (A -7°C, W 35°C) 3,00 2,72 3,00 2,72
Heating capacity (A -7°C, W 55°C) kW 9,00 12,00 9,00 12,00
COP (A -7°C, W 55°C) 2,10 2,29 2,10 2,29
Cooling capacity (A 35°C, W 7°C) kW 8,80 10,70 8,80 10,70
EER (A 35°C, W 7°C) 3,11 2,68 3,11 2,68
Cooling capacity (A 35°C, W 18°C) kW 8,80 10,70 8,80 10,70
EER (A 35°C, W 18°C) 4,63 3,92 4,63 3,92
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,96 / 3,57 4,96 / 3,57 4,96 / 3,57 4,58 / 3,46
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 195 / 140 195 / 140 195 / 140 180 / 135
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34 6,47 / 4,34
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 256 / 171 256 / 171 256 / 171 256 / 171
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26 4,31 / 3,26
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 169 / 127 169 / 127 169 / 127 169 / 127
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++ A++ / A++ A++ / A++
Indoor unit 3kW electric heater WH-SXC09K3E5 WH-SXC09K3E8
Indoor unit 6kW electric heater WH-SXC09K6E5 WH-SXC12K6E5
Indoor unit 9kW electric heater WH-SXC09K9E8 WH-SXC12K9E8
Indoor sound pressure (Heat) dB(A) 33 33 33 33
Indoor sound pressure (Cool) dB(A) 33 33 33 33
Indoor dimension (Height) mm 892 892 892 892
Indoor dimension (Width) mm 500 500 500 500
Indoor dimension (Depth) mm 348 348 348 348
Indoor net weight kg 40 (3kW) / 41 (6kW) 41 40 (3kW) / 41 (9kW) 41
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼
A class pump (Number of speeds) Variable speed Variable speed Variable speed Variable speed
Heating water flow (∆T=5 K. 35°C) L/min 25,8 34,4 25,8 34,4
Outdoor unit WH-UXZ09KE5 WH-UXZ12KE5 WH-UXZ09KE8 WH-UXZ12KE8
Outdoor sound power (Heat) (2) dB(A) 65 65 65 65
Outdoor dimension (Height) mm 1.340 1.340 1.340 1.340
Outdoor dimension (Width) mm 900 900 900 900
Outdoor dimension (Depth) mm 320 320 320 320
Outdoor net weight kg 88 88 90 90
Refrigerant (R32) / CO2 Eq. kg / T 1,60 / 1,080 1,60 / 1,080 1,60 / 1,080 1,60 / 1,080
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70) 1/2 (12,70)
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30 3 ~ 30
Elevation difference (in/out) m 20 20 20 20
Pipe length for additional gas m 10 10 10 10
Additional gas amount g/m 30 30 30 30
Operation range - Outdoor ambient (Heat) °C -28 ~ +35 -28 ~ +35 -28 ~ +35 -28 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43
Water outlet (Heat) (3) °C 20 ~ 60 20 ~ 60 20 ~ 60 20 ~ 60
Electrical information 3kW — 6kW 6kW 3kW — 9kW 9kW
Electric backup heater kW 3,00 — 6,00 6,00 3,00 — 9,00 9,00
Recommended fuse A 30 / 15 or 16 — 30 / 30 30 / 30 20 / 15 or 16 — 20 / 20 20 / 20
Recommended minimum cable size, supply 1 (4) mm² 3x4,0 — 3x4,0 3x4,0 5x1,5 — 5x1,5 5x1,5
Recommended minimum cable size, supply 2 (4) mm² 3x1,5 — 3x4,0 3x4,0 3x1,5 — 5x1,5 5x1,5
(1) Scale from A+++ to D.
(2) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7°C.
(3) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
*** Tentative data.

Complementary products