K Generation 1 phase - 3 phase · R32

Previous capacity Next capacity

Aquarea T-CAP Bi-Bloc K Generation

A revolution in design, efficiency, connectivity and sustainability.
Aquarea K Generation is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance.
Aquarea T-CAP is the range for retrofit and new builds, keeping Total Capacity even at extremely cold ambient.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.

Specifications

See all
K Generation 1 phase - 3 phase · R32
9 kW
Heating capacity (A +7°C, W 35°C) kW 9,00
COP (A +7°C, W 35°C) 5,03
Heating capacity (A +7°C, W 55°C) kW 9,00
COP (A +7°C, W 55°C) 3,07
Heating capacity (A +2°C, W 35°C) kW 9,00
COP (A +2°C, W 35°C) 3,69
Heating capacity (A +2°C, W 55°C) kW 9,00
COP (A +2°C, W 55°C) 2,31
Heating capacity (A -7°C, W 35°C) kW 9,00
COP (A -7°C, W 35°C) 3,00
Heating capacity (A -7°C, W 55°C) kW 9,00
COP (A -7°C, W 55°C) 2,10
Cooling capacity (A 35°C, W 7°C) kW 8,80
EER (A 35°C, W 7°C) 3,11
Cooling capacity (A 35°C, W 18°C) kW 8,80
EER (A 35°C, W 18°C) 4,63
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,96 / 3,57
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 195 / 140
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,47 / 4,34
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 256 / 171
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,31 / 3,26
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 169 / 127
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++
Indoor sound pressure (Heat) dB(A) 33
Indoor sound pressure (Cool) dB(A) 33
Indoor dimension (Height) mm 892
Indoor dimension (Width) mm 500
Indoor dimension (Depth) mm 348
Indoor net weight kg 40 (3kW) / 41 (6kW)
Water pipe connector Inch R 1¼
A class pump (Number of speeds) Variable speed
Heating water flow (∆T=5 K. 35°C) L/min 25,8
Outdoor unit WH-UXZ09KE5
Outdoor dimension (Height) mm 1.340
Outdoor dimension (Width) mm 900
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 88
Refrigerant (R32) / CO2 Eq. kg / T 1,60 / 1,080
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 30
Elevation difference (in/out) m 20
Pipe length for additional gas m 10
Additional gas amount g/m 30
Operation range - Outdoor ambient (Heat) °C -28 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43
(1) Scale from A+++ to D.
(2) Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7°C.
(3) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
*** Tentative data.

Complementary products