PACi Standard Ceiling • R32

This range of ceiling mounted units feature a DC fan motor for increased efficiency and reduced operating sound levels.

All the units are the same height and depth for a uniform appearance in mixed installations. A knock out is provided to allow for supplementary fresh air for improved air quality.

Specifications

See all
PACi Standard Ceiling • R32
7.1 kW
Kit KIT-71PT2Z5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 7,1
Cooling capacity (Min) kW 2,0
Cooling capacity (Max) kW 7,7
EER (Nominal) (1) W/W 3,55
SEER (2) 6,5 A++
Pdesign (cooling) kW 7,1
Input power cooling (Nominal) kW 2,00
Annual energy consumption cooling (3) kWh/a 382
Annual energy consumption cooling (3) kWh/a 382
Heating capacity (Nominal) kW 7,1
Heating capacity (Min) kW 1,8
Heating capacity (Max) kW 8,1
COP (Nominal) (1) W/W 4,41
SCOP (2) 4,3 A+
Pdesign at -10°C kW 6,0
Input power heating (Nominal) kW 1,62
Annual energy consumption heating (3) kWh/a 1953
Indoor unit S-71PT2E5B
Indoor air flow (Hi) m³/min 21,0
Indoor air flow (Med) m³/min 18,0
Indoor air flow (Lo) m³/min 15,5
Moisture removal volume L/h 4,2
Indoor sound pressure (Med) (4) dB(A) 35
Indoor sound pressure (Lo) (4) dB(A) 31
Indoor sound power (Hi) dB(A) 57
Indoor sound power (Med) dB(A) 53
Indoor sound power (Lo) dB(A) 49
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1275
Indoor dimension (Depth) mm 690
Indoor net weight kg 33
Outdoor unit U-71PZ2E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 9,70
Current in cooling (1p 230V / 3p 400) A 9,30
Current in cooling (1p 240V / 3p 415) A 8,90
Current in heating (1p 220V / 3p 380) A 7,85
Current in heating (1p 230V / 3p 400) A 7,50
Current in heating (1p 240V / 3p 415) A 7,20
Outdoor air flow (Cool) m³/min 50
Outdoor air flow (Heat) m³/min 45
Outdoor sound pressure (Cool -Hi) dB(A) 49
Outdoor sound pressure (Heat -Hi) dB(A) 49
Outdoor sound power (Cool -Hi) dB(A) 69
Outdoor sound power (Heat -Hi) dB(A) 69
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 44
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 35
Refrigerant (R32) / CO2 Eq. kg / T 1,45 / 0,979
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C 43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C 24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.