Low Static Pressure Hide Away Inverter • R32
Low static pressure hide away with compact indoor unit only 200m high
The duct can also be connected to KNX, Modbus interfaces for easy integration with your BMS systems. This interfaces have dry contacts (ON/OFF, error message) for easy integration.
Discover the latest generation of air conditioning system
Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost, creating a clean air, free of viruses, bacteria, pollen and odours.
A range of products designed for you
From the smaller 1X1 to the more complete 5x1 solutions, it doesn’t matter which your need is. Panasonic can offers you the best solution to get the best clima in your home.
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience during the whole year.
Great savings and improved wellness
Our air conditioners produce the highest comfort with a very small energy cost, creating a clean air, free of viruses, bacteria, pollen and odours.
A range of products designed for you
From the smaller 1X1 to the more complete 5x1 solutions, it doesn’t matter which your need is. Panasonic can offers you the best solution to get the best clima in your home.
A comfortable home all year round
Our air conditioners give you the most comfortable temperature all year long, heating in winter, cooling in summer and cleaning the ambience during the whole year.
The air conditioning connects with the future
Specifikacije
Low Static Pressure Hide Away Inverter • R32 | |||
---|---|---|---|
2.5 kW | |||
Kit | KIT-Z25-UD3 | ||
Cooling capacity (Nominal) | kW | 2,50 | |
Cooling capacity (Min) | kW | 0,85 | |
Cooling capacity (Max) | kW | 3,20 | |
EER (Nominal) (1) | W/W | 4,31 | |
EER (Min) (1) | W/W | 3,54 | |
EER (Max) (1) | W/W | 3,76 | |
SEER (2) | 5,90 A+ | ||
Pdesign (cooling) | kW | 2,50 | |
Input power cooling (Nominal) | kW | 0,58 | |
Input power cooling (Min) | kW | 0,24 | |
Input power cooling (Max) | kW | 0,85 | |
Annual energy consumption cooling (3) | kWh/a | 148,00 | |
Heating capacity (Nominal) | kW | 3,20 | |
Heating capacity (Min) | kW | 0,85 | |
Heating capacity (Max) | kW | 4,60 | |
Heating capacity at -7°C | kW | 2,60 | |
COP (Nominal) (1) | W/W | 4,00 | |
COP (Min) (1) | W/W | 3,70 | |
COP (Max) (1) | W/W | 3,68 | |
SCOP (2) | 4,20 A+ | ||
Pdesign at -10°C | kW | 2,60 | |
Input power heating (Nominal) | kW | 0,80 | |
Input power heating (Min) | kW | 0,23 | |
Input power heating (Max) | kW | 1,25 | |
Annual energy consumption heating (3) | kWh/a | 867 | |
Indoor unit | CS-Z25UD3EAW | ||
External static pressure (Min) (7) | Pa | 15 | |
External static pressure (Max) (7) | Pa | 45 | |
Indoor power source | V | 230 | |
Indoor air flow (Cool) | m³/min | 10,5 | |
Indoor air flow (Heat) | m³/min | 10,5 | |
Moisture removal volume | L/h | 1,5 | |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 33 | |
Indoor sound pressure (Cool -Lo) (4) | dB(A) | 27 | |
Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 24 | |
Indoor sound pressure (Heat -Hi) (4) | dB(A) | 35 | |
Indoor sound pressure (Heat -Lo) (4) | dB(A) | 27 | |
Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 24 | |
Indoor dimension (Height) | mm | 200 | |
Indoor dimension (Width) | mm | 750 | |
Indoor dimension (Depth) | mm | 640 | |
Indoor net weight | kg | 19 | |
Outdoor unit | CU-Z25UBEA | ||
Outdoor power source | V | 230 | |
Outdoor recommended fuse | A | 16 | |
Outdoor connection indoor / outdoor | mm² | 4 x 1,5 ~ 2,5 | |
Outdoor air flow (Cool) | m³/min | 28,7 | |
Outdoor air flow (Heat) | m³/min | 27,2 | |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 46 | |
Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 47 | |
Outdoor dimension (Height) (5) | mm | 542 | |
Outdoor dimension (Width) (5) | mm | 780 | |
Outdoor dimension (Depth) (5) | mm | 289 | |
Outdoor net weight | kg | 33 | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | |
Pipe diameter (Gas) | Inch (mm) | 3/8 (9,52) | |
Pipe length range | m | 3 ~ 20 | |
Elevation difference (in/out) (6) | m | 15 | |
Pipe length for additional gas | m | 7,5 | |
Additional gas amount | g/m | 10 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 0,88 / 0,594 | |
Operating range (Cool - Min) | °C | -10 | |
Operating range (Cool - Max) | °C | +43 | |
Operating range (Heat - Min) | °C | -15 | |
Operating range (Heat - Max) | °C | +24 |
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position of 1,5m below the unit with 1m duct on the suction side and 2m duct on the discharge side. For outdoor unit 1m in front and 1m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612.
(5) Add 100mm for indoor unit or 70mm for outdoor unit for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.
(7) The specification listed on the table indicates values under the condition of 25Pa (2,5mmAq) which are applied for factory default setting. Change switch on PCB from Hi to S-Hi to have more than 6,0mmAq.