Aquarea HT Bi-bloc F Generation 1 Phase / 3 Phase. Heating Only • R407C

Aquarea, an innovative new low-energy system based on Air to Water heat pump technology


Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.
Aquarea HT can produce a flow temperature of 65°C making it the ideal high efficiency replacement for oil/gas boilers connected to high temperature radiators.
The Bi‑Bloc system: The system, separate indoor and outdoor units, connects to the heating and/or hot water system.

A heat pump turns heat energy outside into warmth inside

Specifikacije

See all
Aquarea HT Bi-bloc F Generation 1 Phase / 3 Phase. Heating Only • R407C
9 kW
Kit KIT-WHF09F3E8
Heating capacity (A +7°C, W 35°C) kW 9,00
COP (A +7°C, W 35°C) 4,64
Heating capacity (A +7°C, W 55°C) kW 9,00
COP (A +7°C, W 55°C) 2,48
Heating capacity (A +2°C, W 35°C) kW 9,00
COP (A +2°C, W 35°C) 3,45
Heating capacity (A +2°C, W 55°C) kW 9,00
COP (A +2°C, W 55°C) 2,06
Heating capacity (A -7°C, W 35°C) kW 9,00
COP (A -7°C, W 35°C) 2,74
Heating capacity (A -7°C, W 55°C) kW 9,00
COP (A -7°C, W 55°C) 1,79
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 153 / 125
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 3,90 / 3,20
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 191 / 156
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,85 / 3,98
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 137 / 116
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 3,50 / 2,98
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+ / A+
Indoor unit WH-SHF09F3E8
Indoor sound pressure (Heat) dB(A) 33
Indoor sound pressure (Cool) dB(A) 33
Indoor dimension (Height) mm 892
Indoor dimension (Width) mm 502
Indoor dimension (Depth) mm 353
Indoor net weight kg 47
Water pipe connector Inch R 1¼
A class pump (Number of speeds) 7
A class pump (Input power Min) W 38
A class pump (Input power Max) W 100
Heating water flow (∆T=5 K. 35°C) L/min 25,80
Capacity of integrated electric heater kW 3,00
Indoor recommended fuse A 30 / 16 
Recommended cable size, supply 1 mm² 5 x 1,5
Recommended cable size, supply 2 mm² 3 x 1,5
Outdoor unit WH-UH09FE8
Outdoor sound power part load (Heat) (3) dB(A)
Outdoor sound power full load (Heat) dB(A) 66
Outdoor dimension (Height) mm 1340
Outdoor dimension (Width) mm 900
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 110
Refrigerant (R407C) / CO2 Eq. kg / T 2,90 / 5,145
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 3 ~ 30
Elevation difference (in/out) m 20
Pipe length for additional gas m 10
Additional gas amount g/m 70
Operation range (Outdoor ambient) °C -20 ~ +35
Water outlet (Heat) °C 25 ~ 65

(1) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
EER and COP calculation is based in accordance to EN14511.

Complementary products