PACi Elite adaptive ducted unit - PF3 - R32

Newly designed adaptive ducted unit - PF3 for R32 PACi

2 installation possibilities (horizontal / vertical) with high external static pressure 150Pa allows flexible installation.

Bringing nature’s balance indoors

New adaptive ducted PF3

The next generation of commercial air conditioners is here

Specifikacije

See all
PACi Elite adaptive ducted unit - PF3 - R32
3.6 kW
Kit KIT-36PF3ZH25
Remote controller CZ-RTC6
Cooling capacity (Nominal) kW 3,4
Cooling capacity (Min) kW 1,5
Cooling capacity (Max) kW 4,0
EER (Nominal) (1) W/W 4,36
EER (Min) (1) W/W 5,36
EER (Max) (1) W/W 2,25
SEER/ηsc (2) % 6,3 A++
Pdesign (cooling) kW 3,4
Input power cooling (Nominal) kW 0,78
Input power cooling (Min) kW 0,28
Input power cooling (Max) kW 1,78
Annual energy consumption cooling (3) kWh/a 188
Heating capacity (Nominal) kW 4,0
Heating capacity (Min) kW 1,5
Heating capacity (Max) kW 5,0
COP (Nominal) (1) W/W 4,35
COP (Min) (1) W/W 6,52
COP (Max) (1) W/W 2,84
SCOP/ηsc (2) % 4,4 A+
Pdesign at -10°C kW 2,4
Input power heating (Nominal) kW 0,92
Input power heating (Min) kW 0,23
Input power heating (Max) kW 1,76
Annual energy consumption heating (3) kWh/a 762
Indoor unit S-3650PF3E
External static pressure (Nominal) (4) Pa 30
External static pressure (Min) (4) Pa 10
External static pressure (Max) (4) Pa 150
Moisture removal volume L/h 0,9
Indoor air flow (Hi) m³/min 14,0
Indoor air flow (Med) m³/min 13,0
Indoor air flow (Lo) m³/min 10,0
Indoor sound pressure (Hi) (5) dB(A) 32
Indoor sound pressure (Med) (5) dB(A) 27
Indoor sound pressure (Lo) (5) dB(A) 22
Indoor sound power (Hi) dB(A) 53
Indoor sound power (Med) dB(A) 50
Indoor sound power (Lo) dB(A) 45
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 800
Indoor dimension (Depth) mm 730
Indoor net weight kg 25
nanoe X Generator Mark 2
Outdoor unit U-36PZH2E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 3,60
Current in cooling (1p 230V / 3p 400) A 3,45
Current in cooling (1p 240V / 3p 415) A 3,30
Current in heating (1p 220V / 3p 380) A 4,30
Current in heating (1p 230V / 3p 400) A 4,10
Current in heating (1p 240V / 3p 415) A 3,90
Outdoor air flow (Cool) m³/min 40
Outdoor air flow (Heat) m³/min 40
Outdoor sound pressure (Cool -Hi) dB(A) 43
Outdoor sound pressure (Heat -Hi) dB(A) 44
Outdoor sound power (Cool -Hi) dB(A) 62
Outdoor sound power (Heat -Hi) dB(A) 64
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 43
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (6) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 20
Refrigerant (R32) / CO2 Eq. kg / T 1,15 / 0,776
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values is calculated based on EN 14825.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Medium External static pressure setting from factory.
(5) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
(7) For models 100~140PZH2E5(8), it is possible to operate the lowest -20°C in the computer rooms with the piping length of 30m or less.
* Recommended fuse for the indoor 3A.
** Above values are in the case of standard installation(horizontal installation in the celling, rear side air intake) and nanoe™ X OFF.

Complementary products