Heatcharge VZ Inverter+ • R32

Previous capacity Next capacity

Heatcharge. Energy Charge System.

Energy class A+++ and offers maximum comfort and energy savings. This powerful air heat pump is designed for commercial and residential climate that places extremely high demands on the heating system.

Bringing nature’s balance indoors

Discover the latest generation of air conditioning system

The air conditioning connects with the future

Specifications

See all
Heatcharge VZ Inverter+ • R32
3.5 kW
Kit KIT-VZ12-SKE
Cooling capacity (Nominal) kW 3,50
Cooling capacity (Min) kW 0,60
Cooling capacity (Max) kW 4,00
SEER (2) 10,00 A+++
Pdesign (cooling) kW 3,50
Input power cooling (Nominal) kW 0,80
Input power cooling (Min) kW 0,14
Input power cooling (Max) kW 0,98
Annual energy consumption cooling (3) kWh/a 122,00
Heating capacity (Nominal) kW 4,20
Heating capacity (Min) kW 0,60
Heating capacity (Max) kW 9,20
Heating capacity at -7°C kW 5,60
COP (Nominal) (1) W/W 5,04
SCOP (2) 5,90 A+++
Pdesign at -10°C kW 4,20
Input power heating (Nominal) kW 0,83
Input power heating (Min) kW 0,14
Input power heating (Max) kW 3,16
Annual energy consumption heating (3) kWh/a 995
Indoor unit CS-VZ12SKE
Indoor power source V 230
Indoor recommended fuse A 16
Indoor connection indoor / outdoor mm² 4 x 1,5
Indoor air flow (Cool) m³/min 12,9
Indoor air flow (Heat) m³/min 15,9
Indoor sound pressure (Cool -Hi) (4) dB(A) 45
Indoor sound pressure (Cool -Hi) (4) dB(A) 45
Indoor sound pressure (Cool -Lo) (4) dB(A) 33
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 18
Indoor sound pressure (Heat -Hi) (4) dB(A) 45
Indoor sound pressure (Heat -Lo) (4) dB(A) 29
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 18
Indoor dimension (Height) mm 295
Indoor dimension (Width) mm 798
Indoor dimension (Depth) mm 375
Indoor net weight kg 14,5
Outdoor unit CU-VZ12SKE
Outdoor air flow (Cool) m³/min 35,4
Outdoor air flow (Heat) m³/min 33,9
Outdoor sound pressure (Cool -Hi) (4) dB(A) 50
Outdoor sound pressure (Cool -Hi) (4) dB(A) 50
Outdoor sound pressure (Heat -Hi) (4) dB(A) 50
Outdoor dimension (Height) (5) mm 630
Outdoor dimension (Width) (5) mm 799
Outdoor dimension (Depth) (5) mm 299
Outdoor net weight kg 39,5
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52)
Pipe length range m 3 ~ 15
Elevation difference (in/out) (6) m 12
Pipe length for additional gas m 7,5
Additional gas amount g/m 20
Refrigerant (R32) / CO2 Eq. kg / T 1,10 / 0,7425
Operating range (Cool - Min) °C -10
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -30
Operating range (Heat - Max) °C +24
Lowest outdoor temperature tested by 3rd party laboratory (7) °C -35

(1) Energy Label Scale from A+++ to D.

(2) EER and COP calculation is based in accordance to EN14511.

(3) The annual energy consumption is calculated in accordance to EU/626/2011.

(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.

(5) Add 70 mm for piping port.

(6) When installing the outdoor unit at a higher position than the indoor unit.

(7) Tested by 3rd party laboratory, SP, according to EN14511:2013 and SP Method 1721, this temperature is not guaranteed by Factory.