PACi Standard adaptive ducted unit - PF3 - R32

Newly designed adaptive ducted unit - PF3 for R32 PACi

2 installation possibilities (horizontal / vertical) with high external static pressure 150Pa allows flexible installation.

Bringing nature’s balance indoors

Specifications

See all
PACi Standard adaptive ducted unit - PF3 - R32
6.0 kW
Kit KIT-60PF3Z25
Remote controller CZ-RTC6
EER (Min) (1) W/W 4,76
EER (Max) (1) W/W 2,50
SEER/ηsc (2) % 7,1 A++
Annual energy consumption cooling (3) kWh/a 281
COP (Min) (1) W/W 4,86
COP (Max) (1) W/W 2,83
SCOP/ηsc (2) % 4,7 A++
Annual energy consumption heating (3) kWh/a 1289
External static pressure (Nominal) (4) Pa 30
External static pressure (Min) (4) Pa 10
External static pressure (Max) (4) Pa 150
Moisture removal volume L/h 1,7
Indoor air flow (Hi) m³/min 21,0
Indoor air flow (Med) m³/min 19,0
Indoor air flow (Lo) m³/min 15,0
Indoor sound pressure (Hi) (5) dB(A) 30
Indoor sound pressure (Med) (5) dB(A) 26
Indoor sound pressure (Lo) (5) dB(A) 23
Indoor sound power (Hi) dB(A) 53
Indoor sound power (Med) dB(A) 49
Indoor sound power (Lo) dB(A) 46
nanoe X Generator Mark 2
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 7,55
Current in cooling (1p 230V / 3p 400) A 7,20
Current in cooling (1p 240V / 3p 415) A 6,90
Current in heating (1p 220V / 3p 380) A 6,40
Current in heating (1p 230V / 3p 400) A 6,15
Current in heating (1p 240V / 3p 415) A 5,90
Outdoor air flow (Cool) m³/min 40
Outdoor air flow (Heat) m³/min 45
Outdoor sound pressure (Cool -Hi) dB(A) 46
Outdoor sound pressure (Heat -Hi) dB(A) 48
Outdoor sound power (Cool -Hi) dB(A) 65
Outdoor sound power (Heat -Hi) dB(A) 68
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Pipe length range m 3 ~ 40
Elevation difference (in/out) (6) m 30
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values is calculated based on EN 14825.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Medium External static pressure setting from factory.
(5) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3A.
** Above values are in the case of standard installation(horizontal installation in the celling, rear side air intake) and nanoe™ X OFF.