PACi Standard 4 Way 90x90 • R32

Large capacity PACi. Trusted power and high efficiency.

Thanks to advances in design and technology such as the high performance turbo fan, more efficient and silent, the nanoe™ X air cleaner, the U2 Panasonic 4 way 90x90 cassette offers high energy saving, fresh air and comfort.

Bringing nature’s balance indoors

Specifications

See all
PACi Standard 4 Way 90x90 • R32
10.0 kW
Kit KIT-100PU2Z8
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 10,0
Cooling capacity (Min) kW 3,0
Cooling capacity (Max) kW 11,5
EER (Nominal) (1) W/W 3,82
EER (Min) (1) W/W 5,36
EER (Max) (1) W/W 2,88
SEER (2) 6,7 A++
Pdesign (cooling) kW 10,0
Input power cooling (Nominal) kW 2,62
Annual energy consumption cooling (3) kWh/a 521
Input power cooling (Min) kW 0,56
Input power cooling (Max) kW 4,00
Annual energy consumption cooling (3) kWh/a 521
Heating capacity (Nominal) kW 10,0
Heating capacity (Min) kW 3,0
Heating capacity (Max) kW 14,0
COP (Nominal) (1) W/W 4,93
COP (Min) (1) W/W 3,59
COP (Max) (1) W/W 5,36
SCOP (2) 4,4 A+
Pdesign at -10°C kW 10,0
Input power heating (Nominal) kW 2,03
Input power heating (Min) kW 0,56
Input power heating (Max) kW 3,90
Annual energy consumption heating (3) kWh/a 3182
Indoor unit S-100PU2E5B
Indoor air flow (Hi) m³/min 36,0
Indoor air flow (Med) m³/min 26,0
Indoor air flow (Lo) m³/min 18,0
Moisture removal volume L/h 2,7
Indoor sound pressure (Med) (4) dB(A) 38
Indoor sound pressure (Lo) (4) dB(A) 32
Indoor sound power (Hi) dB(A) 60
Indoor sound power (Med) dB(A) 53
Indoor sound power (Lo) dB(A) 47
Indoor dimension (Height) mm 319
Indoor dimension (Width) mm 840
Indoor dimension (Depth) mm 840
Panel dimension (Height) mm 33,5
Panel dimension (Depth) mm 950
Indoor net weight kg 25
Panel net weight kg 5
nanoe X Generator Mark 1
Outdoor unit U-100PZ2E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 4,10
Current in cooling (1p 230V / 3p 400) A 3,90
Current in cooling (1p 240V / 3p 415) A 3,75
Current in heating (1p 220V / 3p 380) A 3,15
Current in heating (1p 230V / 3p 400) A 3,00
Current in heating (1p 240V / 3p 415) A 2,90
Outdoor air flow (Cool) m³/min 76
Outdoor air flow (Heat) m³/min 70
Outdoor sound pressure (Cool -Hi) dB(A) 52
Outdoor sound pressure (Heat -Hi) dB(A) 52
Outdoor sound power (Cool -Hi) dB(A) 70
Outdoor sound power (Heat -Hi) dB(A) 70
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 90
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 2,60 / 1,755
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C 43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C 24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.