PACi Elite | R32 | PT Deckenunterbaugeräte

Ceiling mounted units provides large and wide air distribution which is good for big rooms. The height and depth of all capacities are the same for unified appearance in mixed installations.

Technische Daten

Alles anzeigen
PACi Elite | R32 | PT Deckenunterbaugeräte
10.0 kW
Kit KIT-100PT2ZH5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 10,0
Cooling capacity (Min) kW 3,1
Cooling capacity (Max) kW 12,5
EER (Nominal) (1) W/W 4,05
SEER (2) 7,0 A++
Pdesign (cooling) kW 10,0
Input power cooling (Nominal) kW 2,47
Annual energy consumption cooling (3) kWh/a 500
Heating capacity (Nominal) kW 11,2
Heating capacity (Min) kW 3,1
Heating capacity (Max) kW 14,0
COP (Nominal) (1) W/W 4,31
SCOP (2) 4,6 A++
Pdesign at -10°C kW 8,0
Input power heating (Nominal) kW 2,60
Annual energy consumption heating (3) kWh/a 2435
Indoor unit S-100PT2E5B
Indoor air flow (Hi) m³/min 30,0
Indoor air flow (Med) m³/min 25,0
Indoor air flow (Lo) m³/min 23,0
Indoor sound pressure (Med) (4) dB(A) 37
Indoor sound pressure (Lo) (4) dB(A) 35
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1590
Indoor dimension (Depth) mm 690
Indoor net weight kg 40
Outdoor unit U-100PZH2E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 11,40
Current in cooling (1p 230V / 3p 400) A 10,90 -10,50
Current in cooling (1p 240V / 3p 415) A 12,00
Current in heating (1p 220V / 3p 380) A 11,50
Current in heating (1p 230V / 3p 400) A 11,00
Current in heating (1p 240V / 3p 415) A 118,00
Outdoor air flow (Cool) m³/min 108
Outdoor air flow (Heat) m³/min 52
Outdoor sound pressure (Cool -Hi) dB(A) 52
Outdoor sound pressure (Heat -Hi) dB(A) 69
Outdoor sound power (Cool -Hi) dB(A) 69
Outdoor sound power (Heat -Hi) dB(A) 1416
Outdoor dimension (Height) mm 940
Outdoor dimension (Width) mm 340
Outdoor dimension (Depth) mm 99
Outdoor net weight kg 3/8 (9,52)
Pipe diameter (Liquid) Inch (mm) 5/8 (15,88)
Pipe diameter (Gas) Inch (mm) 5 ~ 85
Pipe length range m 30
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 45
Additional gas amount g/m 3,05 / 2,059
Refrigerant (R32) / CO2 Eq. kg / T -20 (6)
Operating range (Cool - Min) °C 46
Operating range (Cool - Max) °C -20
Operating range (Heat - Min) °C 24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
(6) For models 100 ~ 140PZH2E5(8), it is possible to operate the lowest -20 °C in the computer rooms with the piping length of 30 m or less.
* Recommended fuse for the indoor 3 A.