„Etherea Inverter+“, sidabro spalvos • R32

Puikios, stilingos „Etherea“ funkcijos.

„Etherea“ su „nanoe™ X“ technologija: išskirtinis efektyvumas A+++, patogumas („Super Quiet“ technologija – vos 19 dB(A)) ir sveikas oras – viskas viename modelyje.


Produktų asortimentas, sukurtas Jums

Atraskite naujausios kartos oro kondicionavimo sistemą

Gamtos pusiausvyros užtikrinimas patalpose

Oro kondicionieriaus ir ateities sąjunga

Specifications

Rodyti viską
„Etherea Inverter+“, sidabro spalvos • R32 SINGLE PHASE
5 kW 2.1 kW 2.5 kW 3.5 kW
Kit KIT-XZ50-VKE KIT-XZ20-VKE KIT-XZ25-VKE
Cooling capacity (Nominal) kW 5,00 2,05 2,50 3,50 (0,85 - 4,00)
Cooling capacity (Min) kW 0,98 0,75 0,85
Cooling capacity (Max) kW 6,00 2,40 3,20
EER (Nominal) (1) W/W 3,55 4,56 4,81 4,07 (3,54 - 3,70)
EER (Min) (1) W/W 3,50 3,13 3,54
EER (Max) (1) W/W 3,08 4,32 4,05
SEER (2) 7,90 A++ 7,50 A++ 8,50 A+++ 8,50 A+++
Pdesign (cooling) kW 5,00 2,10 2,50
Input power cooling (Nominal) kW 1,41 0,45 0,52
Input power cooling (Min) kW 0,28 0,24 0,24
Input power cooling (Max) kW 1,95 0,56 0,79
Annual energy consumption cooling (3) kWh/a 222,00 98,00 103,00
Heating capacity (Nominal) kW 5,80 2,80 3,40 4,00 (0,80 - 5,80)
Heating capacity (Min) kW 0,98 0,70 0,80
Heating capacity (Max) kW 8,00 4,00 5,00
Heating capacity at -7°C kW 4,80 2,38 2,95 3,20
COP (Nominal) (1) W/W 4,03 4,52 4,79 4,35 (4,44 - 3,72)
COP (Min) (1) W/W 2,88 3,89 4,44
COP (Max) (1) W/W 3,16 4,04 3,97
SCOP (2) 4,70 A++ 4,70 A++ 5,10 A+++ 5,10 A+++
Pdesign at -10°C kW 4,20 2,10 2,70
Input power heating (Nominal) kW 1,44 0,62 0,71
Input power heating (Min) kW 0,34 0,18 0,18
Input power heating (Max) kW 2,53 0,99 1,26
Annual energy consumption heating (3) kWh/a 1251 626 741
Indoor unit CS-XZ50VKEW CS-XZ20VKEW CS-XZ25VKEW
Indoor power source V 230 230 230
Indoor recommended fuse A 16 16 16
Indoor connection indoor / outdoor mm² 4 x 2,5 4 x 1,5 4 x 1,5
Indoor air flow (Cool) m³/min 19,1 9,9 10,2
Indoor air flow (Heat) m³/min 20,5 10,7 11,2
Moisture removal volume L/h 2,8 1,3 1,5
Indoor sound pressure (Cool -Hi) (4) dB(A) 44 37 39
Indoor sound pressure (Cool -Hi) (4) dB(A) 44 37 39
Indoor sound pressure (Cool -Lo) (4) dB(A) 37 24 25
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 30 19 19
Indoor sound pressure (Heat -Hi) (4) dB(A) 44 38 41
Indoor sound pressure (Heat -Lo) (4) dB(A) 37 25 27
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 30 19 19
Indoor dimension (Height) mm 302 295 295
Indoor dimension (Width) mm 1120 919 919
Indoor dimension (Depth) mm 236 194 194
Indoor net weight kg 12 9 10
nanoe X Generator Mark 1 Mark 1 Mark 1
Outdoor unit CU-Z50VKE CU-Z20VKE CU-Z25VKE
Outdoor air flow (Cool) m³/min 39,8 26,9 28,7
Outdoor air flow (Heat) m³/min 36,9 24,1 27,2
Outdoor sound pressure (Cool -Hi) (4) dB(A) 47 45 46
Outdoor sound pressure (Cool -Hi) (4) dB(A) 47 45 46
Outdoor sound pressure (Heat -Hi) (4) dB(A) 47 46 47
Outdoor dimension (Height) (5) mm 695 542 542
Outdoor dimension (Width) (5) mm 875 780 780
Outdoor dimension (Depth) (5) mm 320 289 289
Outdoor net weight kg 42 27 31
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 3/8 (9,52) 3/8 (9,52)
Pipe length range m 3 ~ 30 3 ~ 15 3 ~ 15
Elevation difference (in/out) (6) m 15 15 15
Pipe length for additional gas m 7,5 7,5 7,5
Additional gas amount g/m 15 10 10
Refrigerant (R32) / CO2 Eq. kg / T 1,15 / 0,776 0,70 / 0,473 0,85 / 0,574 0,85 / 0,574
Operating range (Cool - Min) °C -10 -10 -10 -10 ~ +43
Operating range (Cool - Min) °C -10 -10 -10 -10 ~ +43
Operating range (Cool - Max) °C +43 +43 +43
Operating range (Heat - Min) °C -15 -15 -15
Operating range (Heat - Max) °C +24 +24 +24

1) EER ir COP rodikliai apskaičiuoti pagal standartą EN14511.
2) Energijos etiketės skalė nuo A+++ iki D.
3) Metinės energijos sąnaudos apskaičiuotos pagal ES/626/2011.
4) Vidaus bloko garso slėgio vertė buvo išmatuota 1 m atstumu nuo pagrindinio korpuso priekio ir 0,8 m atstumu nuo bloko apačios. Lauko bloko vertės išmatuotos 1 m atstumu nuo pagrindinio korpuso priekio ir 1 m atstumu nuo galinės pusės. Garso slėgis išmatuotas pagal JIS C 9612. Q-Lo: tylusis režimas. Lo: mažiausias nustatytas ventiliatoriaus greitis.
5) Pridėkite 70 mm vamzdžių išvedžiojimo angai.
6) Kai lauko blokas įrengiamas aukščiau už vidaus bloką.

Papildomi gaminiai