Models
The depth of only 250mm provides greater installation flexibility and the unit can be used in more applications. Ideal for sites with narrow ceiling voids.
Ultra-slim profile: 250mm height for all models.
Specifications
PACi Elite Low Static Pressure Hide Away • R32 | SINGLE PHASE | THREE PHASE | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3.6 kW | 5.0 kW | 6.0 kW | 7.1 kW | 10.0 kW | 12.5 kW | 14.0 kW | 7.1 kW | 10.0 kW | 12.5 kW | 14.0 kW | |||
EER (Nominal) (1) | W/W | 3,85 | 3,35 | 3,40 | 3,40 | 3,95 | 3,35 | 3,15 | 3,40 | 3,95 | 3,35 | 3,15 | |
COP (Nominal) (1) | W/W | 4,40 | 3,35 | 3,75 | 3,68 | 3,90 | 3,70 | 3,50 | 3,68 | 3,90 | 3,70 | 3,50 | |
Refrigerant (R32) / CO2 Eq. | kg / T | — | — | — | — | — | — | — | — | — | — | — | |
EER (Nominal) (1) | W/W | 3,85 | 3,35 | 3,40 | 3,40 | 3,95 | 3,35 | 3,15 | 3,40 | 3,95 | 3,35 | 3,15 | |
COP (Nominal) (1) | W/W | 4,40 | 3,35 | 3,75 | 3,68 | 3,90 | 3,70 | 3,50 | 3,68 | 3,90 | 3,70 | 3,50 | |
External static pressure (Nominal) (4) | Pa | 25 | 25 | 25 | 25 | 40 | 50 | 50 | 25 | 40 | 50 | 50 | |
External static pressure (Min) (4) | Pa | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
External static pressure (Max) (4) | Pa | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |
Indoor sound pressure (Hi) (5) | dB(A) | 35 | 36 | 38 | 38 | 39 | 40 | 41 | 38 | 39 | 40 | 41 | |
Indoor sound pressure (Med) (5) | dB(A) | 33 | 34 | 36 | 36 | 37 | 38 | 39 | 36 | 37 | 38 | 39 | |
Indoor sound pressure (Lo) (5) | dB(A) | 30 | 30 | 31 | 31 | 32 | 33 | 34 | 31 | 32 | 33 | 34 | |
Elevation difference (in/out) (6) | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
Refrigerant (R32) / CO2 Eq. | kg / T | — | — | — | — | — | — | — | — | — | — | — |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Medium external static pressure setting from factory.
(5) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
(7) For models 100 ~ 140PZH2E5(8), it is possible to operate the lowest -20 °C in the computer rooms with the piping length of 30 m or less.
* Recommended fuse for the indoor 3 A.