Aquarea High Performance All in One H Generation 1 Phase • R410A

Aquarea, an innovative new low-energy system based on Air to Water heat pump technology


Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.
Aquarea High Performance is the range for new installations and low consumption homes. Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
Aquarea All in One: This range intelligently integrates the best Hydrokit technology with a premium quality stainless steel tank, which is maintenance-free.

A heat pump turns heat energy outside into warmth inside

Specifications

See all
Aquarea High Performance All in One H Generation 1 Phase • R410A SINGLE PHASE (Power to indoor)
3 kW 5 kW 7 kW 9 kW 12 kW 16 kW
Kit KIT-ADC03HE5 KIT-ADC05HE5 KIT-ADC07HE5 KIT-ADC09HE5 KIT-ADC12HE5 KIT-ADC16HE5
Heating capacity (A +7°C, W 35°C) kW 3,20 5,00 7,00 9,00 12,00 16,00
COP (A +7°C, W 35°C) 5,00 4,63 4,46 4,13 4,74 4,28
Heating capacity (A +7°C, W 55°C) kW 3,20 5,00 6,80 8,90 12,00 14,50
COP (A +7°C, W 55°C) 2,67 2,65 2,63 2,41 2,88 2,68
Heating capacity (A +2°C, W 35°C) kW 3,20 4,20 6,55 6,70 11,40 13,00
COP (A +2°C, W 35°C) 3,56 3,11 3,34 3,13 3,44 3,28
Heating capacity (A +2°C, W 55°C) kW 3,20 4,10 6,00 6,00 9,10 9,80
COP (A +2°C, W 55°C) 2,15 1,98 1,99 1,99 2,20 2,17
Heating capacity (A -7°C, W 35°C) kW 3,20 4,20 5,15 5,90 10,00 11,40
COP (A -7°C, W 35°C) 2,69 2,59 2,68 2,52 2,73 2,57
Heating capacity (A -7°C, W 55°C) kW 3,20 3,55 4,80 5,80 8,20 9,00
COP (A -7°C, W 55°C) 1,72 1,71 1,89 1,88 1,92 1,82
Cooling capacity (A 35°C, W 7°C) kW 3,20 4,50 6,00 7,00 10,00 12,20
EER (A 35°C, W 7°C) 3,08 2,69 2,63 2,43 2,81 2,56
Cooling capacity (A 35°C, W 18°C) kW 3,30 5,00 6,00 7,00 10,00 12,20
EER (A 35°C, W 18°C) 3,75 3,76 3,57 3,26 4,17 4,12
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 195 / 130 195 / 130 190 / 130 190 / 130 190 / 134 190 / 130
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,95 / 3,33 4,95 / 3,33 4,83 / 3,33 4,83 / 3,33 4,83 / 3,43 4,83 / 3,33
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 244 / 163 244 / 163 225 / 160 225 / 160 245 / 159 245 / 169
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,18 / 4,15 6,18 / 4,15 5,70 / 4,08 5,70 / 4,08 6,20 / 4,05 6,20 / 4,30
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 150 / 103 150 / 103 160 / 115 160 / 115 168 / 121 168 / 121
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 3,83 / 2,65 3,83 / 2,65 4,08 / 2,95 4,08 / 2,95 4,28 / 3,10 4,28 / 3,10
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+ A++ / A+ A++ / A+ A++ / A+ A++ / A+ A++ / A+
Indoor unit WH-ADC0309H3E5 WH-ADC0309H3E5 WH-ADC0309H3E5 WH-ADC0309H3E5 WH-ADC1216H6E5 WH-ADC1216H6E5
Indoor sound pressure (Heat) dB(A) 28 28 28 28 33 33
Indoor sound pressure (Cool) dB(A) 28 28 28 28 33 33
Indoor dimension (Height) mm 1800 1800 1800 1800 1800 1800
Indoor dimension (Width) mm 598 598 598 598 598 598
Indoor dimension (Depth) mm 717 717 717 717 717 717
Indoor net weight kg 124 124 124 124 124 124
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼ R 1¼ R 1¼
A class pump (Number of speeds) Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed Variable Speed
A class pump (Input power Min) W 30 30 30 30 36 36
A class pump (Input power Max) W 120 120 120 120 152 152
Heating water flow (∆T=5 K. 35°C) L/min 9,20 14,30 20,10 25,80 34,40 45,90
Capacity of integrated electric heater kW 3,00 3,00 3,00 3,00 6,00 6,00
Indoor recommended fuse A 15 / 15 15 / 15 30 / 15 30 / 15 30 / 30 30 / 30
Recommended cable size, supply 1 mm² 3 x 1,5 3 x 1,5 3 x 2,5 3 x 2,5 3 x 4,0 3 x 4,0
Recommended cable size, supply 2 mm² 3 x 1,5 3 x 1,5 3 x 1,5 3 x 1,5 3 x 4,0 3 x 4,0
Water volume L 185 185 185 185 185 185
Maximum water temperature °C 65 65 65 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
Tapping profile according EN16147 L L L L L L
DHW tank ERP average climate efficiency rating (2) A+ to F A+ A+ A A A A
DHW tank ERP warm climate efficiency rating (2) A+ to F A+ A+ A+ A+ A A
DHW tank ERP cold climate efficiency rating (2) A+ to F A A A A A B
DHW tank ERP average climate η ηwh % 120 120 113 113 95 91
DHW tank ERP average climate SCOP 3,00 3,00 2,83 2,83 2,38 2,28
DHW tank ERP warm climate η ηwh % 147 147 132 132 110 107
DHW tank ERP warm climate SCOP 3,68 3,68 3,30 3,30 2,75 2,68
DHW tank ERP cold climate η ηwh % 94 94 86 86 75 72
DHW tank ERP cold climate SCOP 2,35 2,15 2,15 1,88 1,80 1,88
Outdoor unit WH-UD03HE5-1 WH-UD05HE5-1 WH-UD07HE5-1 WH-UD09HE5-1 WH-UD12HE5 WH-UD16HE5
Outdoor sound power part load (Heat) (3) dB(A) 55 55 59 59 65 65
Outdoor sound power full load (Heat) dB(A) 64 65 68 69 69 72
Outdoor sound power full load (Cool) dB(A) 65 66 66 68 68 72
Outdoor dimension (Height) mm 622 622 795 795 1340 1340
Outdoor dimension (Width) mm 824 824 900 900 900 900
Outdoor dimension (Depth) mm 298 298 320 320 320 320
Outdoor net weight kg 39 39 66 66 101 101
Refrigerant (R410A) / CO2 Eq. kg / T 1,20 / 2,506 1,20 / 2,506 1,45 / 3,028 1,45 / 3,028 2,55 / 5,324 2,55 / 5,324
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) 1/2 (12,70) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 40 3 ~ 40 3 ~ 50 3 ~ 50
Elevation difference (in/out) m 5 5 30 30 30 30
Pipe length for additional gas m 10 10 10 10 10 10
Additional gas amount g/m 20 20 30 30 50 50
Operation range (Outdoor ambient) °C -20 ~ +35 -20 ~ +35 -20 ~ +35 -20 ~ +35 -20 ~ +35 -20 ~ +35
Water outlet (Heat) °C 20 ~ 55 20 ~ 55 20 ~ 55 20 ~ 55 20 ~ 55 20 ~ 55
Water outlet (Cool) °C 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20

(1) Scale from A+++ to D.
(2) Scale from A+ to F.
(3) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
EER and COP calculation is based in accordance to EN14511.
This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.

Complementary products