PACi Elite Wall-Mounted • R32

The range units allows for many more applications such as studios, gyms, high ceiling areas and even computer server rooms.

The unit’s compact design and flat face ensure discreet installation, even in a small space.

Specifications

See all
PACi Elite Wall-Mounted • R32
9.5 kW
Kit KIT-100PK2ZH8
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 9,5
Cooling capacity (Min) kW 3,1
Cooling capacity (Max) kW 10,5
EER (Nominal) (1) W/W 3,26
SEER (2) 6,3 A++
Pdesign (cooling) kW 9,5
Input power cooling (Nominal) kW 2,91
Annual energy consumption cooling (3) kWh/a 526
Heating capacity (Nominal) kW 9,5
Heating capacity (Min) kW 3,1
Heating capacity (Max) kW 11,5
COP (Nominal) (1) W/W 3,97
SCOP (2) 4,1 A+
Pdesign at -10°C kW 8,0
Input power heating (Nominal) kW 2,39
Annual energy consumption heating (3) kWh/a 2732
Indoor unit S-100PK2E5B
Indoor air flow (Hi) m³/min 22,0
Indoor air flow (Med) m³/min 18,5
Indoor air flow (Lo) m³/min 15,0
Indoor sound pressure (Med) (4) dB(A) 45
Indoor sound pressure (Lo) (4) dB(A) 41
Indoor dimension (Height) mm 302
Indoor dimension (Width) mm 1120
Indoor dimension (Depth) mm 236
Indoor net weight kg 14
Outdoor unit U-100PZH2E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 4,60
Current in cooling (1p 230V / 3p 400) A 4,35
Current in cooling (1p 240V / 3p 415) A 4,20
Current in heating (1p 220V / 3p 380) A 3,75
Current in heating (1p 230V / 3p 400) A 3,55
Current in heating (1p 240V / 3p 415) A 3,45
Outdoor air flow (Cool) m³/min 118
Outdoor air flow (Heat) m³/min 108
Outdoor sound pressure (Cool -Hi) dB(A) 52
Outdoor sound pressure (Heat -Hi) dB(A) 52
Outdoor sound power (Cool -Hi) dB(A) 69
Outdoor sound power (Heat -Hi) dB(A) 69
Outdoor dimension (Height) mm 1416
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Outdoor net weight kg 99
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 85
Elevation difference (in/out) (5) m 30
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 3,05 / 2,059
Operating range (Cool - Min) °C -20 (6)
Operating range (Cool - Max) °C 46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C 24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
(6) For models 100 ~ 140PZH2E5(8), it is possible to operate the lowest -20 °C in the computer rooms with the piping length of 30 m or less.
* Recommended fuse for the indoor 3 A.