PACi Standard & PACi Elite
PACi Standard
For economy and value
With high quality design and engineering, the PACi Standard is the perfect solution for projects which demand quality on a limited budget. In addition, its compact size and light weight make it ideal for installations with limited space including small commercial and residential applications.
The outdoor unit is much more compact than the previous model. The slim and lightweight design means the PACi outdoor unit can be installed in a number of situations. On the 12,5kW (996 x 940 x 340mm).
PACi Standard. From 6,0 to 14,0kW.
· Good balance, system cost vs energy efficiency
· Top class SEER/SCOP as a Standard Inverter category
SEER: A++ / SCOP: A+ at 10,0kW (in 90x90 Cassette)
· Interchangeable controller with ECOi
· Compact outdoor units
· Twin connection possible
· Cooling operation up to -10°C
· Heating operation up to -15°C
PACi Elite
Newly designed next generation of commercial air conditioning
Outstanding performance at low temperatures, high energy efficiency, power consumption in remote control display. Energy-saving concept. The use of energy saving design for the structure of fans, fan motors, compressors and heat exchangers resulted in high COP value which ranked as one the top class in the industry. CO2 emissions through reduced energy consumption and lowers operating costs.
PACi Elite. From 3,6 to 25,0kW.
· Meeting all necessary safety approvals to ensure quality and safety
· Top-class SEER: A++ / SCOP: A++ at 10,0kW (in 90x90 Cassette)
· Cooling operation is possible when outdoor temperature as high as 46°C
· DC inverter technology combined with R410A
· Cooling operation is possible when outdoor temperature as low as -15°C
· Heating operation is possible when outdoor temperature as low as -20°C
· Compact outdoor units
· Auto restart from outdoor unit
· Twin, Triple and Doble-Twin connection possible
PACi Elite: Excellent SEER and SCOP values
High operating efficiency using DC inverter compressor, DC motor and a heat exchanger design.
Seasonal efficiency for daily energy saving
A. SEER PACi Elite
B. SEER PACi Standard
C. SCOP PACi Elite
D. SCOP PACi Standard
* 90x90 Cassette data.
Increased piping length for greater design flexibility
Adaptable to various building types and sizes.
Maximum piping length: 75m (10,0, 12,5, 14,0kW). 50m (6,0, 7,1kW).
A. Maximum height difference between outdoor unit and indoor unit.
B. Maximum total pipe length.
* 15m if the outdoor unit is below the indoor unit.
Design operation conditions
Cooling operation is possible when outdoor temperature as low as -15°C or as high as 46°C. Heating operation is possible when outdoor temperature as low as -20°C. The remote control temperature setting offers a range from 18°C to 30°C.
A. Cooling design operation conditions
B. Heating design operation conditions