PACi Standard od 7,1 do 14,0 kW. R32

PACi Standard od 7,1 do 14,0 kW

Na istu vanjsku jedinicu mogu se povezati 2 unutarnje jedinice. Panasonicove PACi jedinice mogu se ugraditi kao jednostruki i dvostruki sustav. Unutarnje jedinice mogu se kombinirati u skladu s tablicom za odabir. Rad će uvijek biti istodoban. Sve unutarnje jedinice radit će s istim postavkama.


Ravnoteža prirode u zatvorenom prostoru

Specifikacije

Prikaži sve
PACi Standard od 7,1 do 14,0 kW. R32
10.0 kW 12.5 kW 14.0 kW
Cooling capacity (Nominal) kW 10,0  12,5  14,0 
Cooling capacity (Min) kW 3,0  3,2  3,3 
Cooling capacity (Max) kW 11,5  13,5  15,0 
Heating capacity (Nominal) kW 10,0  12,5  14,0 
Heating capacity (Min) kW 3,0  3,3  3,4 
Heating capacity (Max) kW 14,0  15,0  16,0 
Outdoor connection indoor / outdoor mm² 2x1,5 or 2,5 2x1,5 or 2,5 2x1,5 or 2,5
Outdoor sound pressure (Cool -Hi) dB(A) 52  55  56 
Outdoor sound pressure (Heat -Hi) dB(A) 52 55 56
Outdoor sound power (Cool -Hi) dB(A) 70  73  74 
Outdoor sound power (Heat -Hi) dB(A) 70 73 74
Outdoor dimension (Height) mm 996  996  996 
Outdoor dimension (Width) mm 980  980  980 
Outdoor dimension (Depth) mm 370 370 370
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 5 ~ 50 5 ~ 50 5 ~ 50
Elevation difference (in/out) m 15  / 30 15  / 30 15  / 30
Pipe length for additional gas m 30 30 30
Additional gas amount g/m 45 45 45
Refrigerant (R32) / CO2 Eq. kg / T 2,4 / 1,62 2,8 / 1,89 2,8 / 1,89
Operating range (Cool - Min) °C -10  -10  -10 
Operating range (Cool - Max) °C 43 43 43
Operating range (Heat - Min) °C -15  -15  -15 
Operating range (Heat - Max) °C 24 24 24