Solarne fotonaponske ploče + upravitelj dizalice topline: toplina i besplatna proizvodnja tople vode u domaćinstvu

Key points:
· Increases the amount of self-consumed electricity from the solar system up to 120%
· Control the heat pump’s energy consumption according to the output of electricity from the PV considering the electric energy consumption requirement of the house
· Innovative algorithm balancing the heat pump’s consumption and the in-house comfort, based on the outside temperature and the energy demand of the building
· Easy configuration of the Heat Pump manager system with the PV system

For F and G Generation
Panasonic has developed an innovative algorithm for its HPM (Heat Pump Manager) which drastically improves the Heat Pump’s use of selfgenerated electricity from connected Photovoltaic panels. The Heat Pump will take the electricity generation by the solar system into consideration for the heating system and the domestic hot water production, without reducing comfort in the house.

PV Panel + Inverter + Heat Pump Manager + Aquarea F/G Generation
= Smart Grid Ready
For H Generation
Aquarea H Generation can synchronize with PV panel with simple CZ-NS4P PCB. A part of converting Aquarea in Smart Grid Ready, there is a new advantage, this new PCB allows 0-10V control.
With this Aquarea demand is adapting all moment with the PV Panel production.


PV Panel + Inverter + Aquarea H Generation with CZ-NS4P
= Smart Grid Ready and 0-10V control

Produce and heat Domestic Hot Water for free.

Usporedba u novoj kući Povećanje potrošnje iz vlastite proizvodnje za: 120%
Upravitelj dizalice topline može povećati potrošnju energije koju dizalica topline dobiva iz fotonaponskog sustava sa 352 kWh na 775 kWh godišnje. Rezultat simulacija:
Usporedba u staroj kući Povećanje potrošnje iz vlastite proizvodnje za: 71%
Upravitelj dizalice topline može povećati potrošnju energije koju dizalica topline dobiva iz fotonaponskog sustava sa 526 kWh na 898 kWh godišnje. Rezultat simulacija:
Nova zgrada u Frankfurtu (nije optimizirana)
(Energija) prema mreži (4.129 kWh)

Proizvodnja pomoću fotonap. sustava (5.630 kWh/god)
73% (4.129 kWh)
27% (1.502 kWh)
Nova zgrada u Frankfurtu (eko-optimizirana)
(Energija) prema mreži (3.706 kWh)

Proizvodnja pomoću fotonap. sustava (5.630 kWh/god)
66% (3.706 kWh)
34% (1.924 kWh)
Stara zgrada u Frankfurtu (nije optimizirana)
(Energija) prema mreži (3.955 kWh)

Proizvodnja pomoću fotonap. sustava (5.630 kWh/god)
70% (3.955 kWh)
30% (1.675 kWh)
Stara zgrada u Frankfurtu (eko-optimizirana)
(Energija) prema mreži (3.583 kWh)

Proizvodnja pomoću fotonap. sustava (5.630 kWh/god)
64% (3.583 kWh)
36% (2.047 kWh)
(Energija) iz mreže (4.467 kWh)

Uvjeti:
Instalirani PV kapacitet: 5,64 kWp
Zahtjevi potrošača u kućanstvu: 3,500 kWh/god
Zahtjev za toplu vodu_ 200 l/dan pri 45°C
Standard izolacije (toplinski zahtjev): 35 kWh/m²
Upravljač: Običan
(Energija) iz mreže (4.012 kWh)

Uvjeti:
Instalirani PV kapacitet: 5,64 kWp
Zahtjevi potrošača u kućanstvu: 3,500 kWh/god
Zahtjev za toplu vodu_ 200 l/dan pri 40°C
Standard izolacije (toplinski zahtjev): 35 kWh/m²
Upravljač: ECO
Iz mreže (6.060 kWh)

Uvjeti:
Instalirani PV kapacitet: 5,64 kWp
Zahtjevi potrošača u kućanstvu: 3,500 kWh/god
Zahtjev za toplu vodu_ 200 l/dan pri 45°C
Standard izolacije (toplinski zahtjev): 80 kWh/m²
Upravljač: Običan
PV: Proizvodnja električne energije
Iz mreže (5.627 kWh)

Uvjeti:
Instalirani PV kapacitet: 5,64 kWp
Zahtjevi potrošača u kućanstvu: 3,500 kWh/god
Zahtjev za toplu vodu_ 200 l/dan pri 40°C
Standard izolacije (toplinski zahtjev): 80 kWh/m²
Upravljač: ECO
PV: Proizvodnja električne energije
1. Potrošnja energije kuće / 2. Potrošnja dizalice topline / 3. Korištenje energije u kući
PV + HP kontrola
Kako stvoriti dodatnu vrijednost kombinacije fotonaponska proizvodnja+dizalica topline?
  • Optimizirajte toplinsku pumpu s obzirom na fotonaponsku proizvodnju
  • Kada fotonaponski sustav proizvodi dovoljno za pokrivanje potrošnje dizalice topline, tada će kotao biti prisiljen zagrijavati toplu vodu u domaćinstvu na 55 ili 65 stupnjeva
  • Ako je u instalaciji međuspremnik, temperatura na međuspremniku povećat će se od 1 do 5 stupnjeva ili do 55°C.
*Napajanje uređaja sa Panasonic-PAW-HPM-Solar (HPM + 2 električna ret.)

1. Fotonaponske solarne ploče / 2. Inverter / 3. Električni mjerač* / 4. Električni mjerač* / 5. Električna ploča / 6. Kućanski aparati i rasvjeta / 7. Električna ploča / 8. HPM* / 9. Grijanje i topla voda za kućanstva / 10. Mreža