PACi NX Series Standard ceiling Inverter+ - R32

Ceiling mounted units provide large and wide air distribution which is good for big rooms.

The height and depth of all capacities are the same for unified appearance in mixed installations.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Standard ceiling Inverter+ - R32 SINGLE PHASE
14.0 kW
Kit KIT-140PT3Z5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 14,0
Cooling capacity (Min) kW 3,3
Cooling capacity (Max) kW 15,0
EER (Nominal) (1) W/W 2,98
SEER/ηsc (2) % 228,8 %
Pdesign (cooling) kW 14,0
Input power cooling (Nominal) kW 4,70
Annual energy consumption cooling (3) kWh/a
Heating capacity (Nominal) kW 14,0
Heating capacity (Min) kW 3,4
Heating capacity (Max) kW 16,0
COP (Nominal) (1) W/W 3,70
SCOP/ηsc (2) % 145,3 %
Pdesign at -10°C kW 13,6
Input power heating (Nominal) kW 3,78
Annual energy consumption heating (3) kWh/a
Indoor unit S-1014PT3E
Indoor air flow (Hi) m³/min 35,0
Indoor air flow (Med) m³/min 29,0
Indoor air flow (Lo) m³/min 25,0
Moisture removal volume L/h 6,9
Indoor sound pressure (Med) (4) dB(A) 41
Indoor sound pressure (Lo) (4) dB(A) 36
Indoor sound power (Hi) dB(A) 65
Indoor sound power (Med) dB(A) 59
Indoor sound power (Lo) dB(A) 54
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1.590
Indoor dimension (Depth) mm 690
Indoor net weight kg 40
nanoe X Generator Mark 2
Outdoor unit U-140PZ3E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 22,70
Current in cooling (1p 230V / 3p 400) A 21,70
Current in cooling (1p 240V / 3p 415) A 20,80
Current in heating (1p 220V / 3p 380) A 18,30
Current in heating (1p 230V / 3p 400) A 17,50
Current in heating (1p 240V / 3p 415) A 16,80
Outdoor air flow (Cool) m³/min 84,0
Outdoor air flow (Heat) m³/min 82,0
Outdoor sound pressure (Cool -Hi) dB(A) 56
Outdoor sound pressure (Heat -Hi) dB(A) 56
Outdoor sound power (Cool -Hi) dB(A) 74
Outdoor sound power (Heat -Hi) dB(A) 74
Outdoor dimension (Height) mm 996
Outdoor dimension (Width) mm 980
Outdoor dimension (Depth) mm 370
Outdoor net weight kg 87
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 50
Elevation difference (in/out) (7) m 15 / 30 (8)
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 2,80 / 1,89
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

1) EER and COP calculation is based in accordance with EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values are calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1m in front of the main body and 1m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
7) When installing the outdoor unit at a higher position than the indoor unit.
8) Outdoor unit located lower / outdoor unit located higher.
* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.