PACi NX Series Elite ceiling Inverter+ - R32

Ceiling mounted units provide large and wide air distribution which is good for big rooms

The height and depth of all capacities are the same for unified appearance in mixed installations.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Elite ceiling Inverter+ - R32 SINGLE PHASE THREE PHASE
7.1 kW 10.0 kW 12.5 kW 14.0 kW 7.1 kW 10.0 kW 10.0 kW 12.5 kW 12.5 kW 14.0 kW
Kit KIT-71PT3ZH45 KIT-100PT3ZH45 KIT-125PT3ZH45 KIT-140PT3ZH45 KIT-71PT3ZH48 KIT-100PT3ZH8 KIT-100PT3ZH48 KIT-125PT3ZH8 KIT-125PT3ZH48 KIT-140PT3ZH48
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 6,8 9,5 12,1 13,4 6,8 9,5 9,5 12,1 12,1 13,4
Cooling capacity (Min) kW 2,2 3,1 3,2 3,3 2,2 3,1 3,1 3,2 3,2 3,3
Cooling capacity (Max) kW 9,0 12,5 14,0 16,0 9,0 12,5 12,5 14,0 14,0 16,0
EER (Nominal) (1) W/W 3,91 4,06 3,46 3,21 3,91 4,15 4,06 3,51 3,46 3,21
EER (Min) (1) W/W 2,69 3,29 3,01 2,67 2,69 3,29 3,01 2,67
EER (Max) (1) W/W 5,79 5,34 5,33 5,32 5,79 5,34 5,33 5,32
SEER/ηsc (2) % 7,3 A++ 7,3 A++ 278,4% 263,3% 7,2 A++ 7,2 A++ 7,2 A++ 277,3 % 277,3% 262,4%
Pdesign (cooling) kW 6,8 9,5 12,1 13,4 6,8 9,5 9,5 12,1 12,1 13,4
Input power cooling (Nominal) kW 1,74 2,34 3,50 4,17 1,74 2,29 2,34 3,45 3,50 4,17
Input power cooling (Min) kW 0,38 0,58 0,60 0,62 0,38 0,58 0,60 0,66
Input power cooling (Max) kW 3,35 3,80 4,65 6,00 3,35 3,80 4,65 6,00
Annual energy consumption cooling (3) kWh/a 326 456 331 462 462
Heating capacity (Nominal) kW 8,0 11,2 14,0 16,0 8,0 11,2 11,2 14,0 14,0 16,0
Heating capacity (Min) kW 2,0 3,1 3,2 3,3 2,0 3,1 3,1 3,2 3,2 3,3
Heating capacity (Max) kW 9,0 14,0 16,0 18,0 9,0 14,0 14,0 16,0 16,0 18,0
COP (Nominal) (1) W/W 3,96 4,00 3,78 3,38 3,96 4,09 4,00 3,78 3,78 3,38
COP (Min) (1) W/W 3,16 3,54 3,20 3,10 3,16 3,54 3,20 3,10
COP (Max) (1) W/W 5,56 5,54 5,52 5,50 5,56 5,54 5,52 5,50
SCOP/ηsc (2) % 4,7 A++ 4,5 A+ 175,6% 169,3% 4,7 A++ 4,7 A++ 4,5 A+ 180,9 % 175,6% 169,3%
Pdesign at -10°C kW 4,7 7,8 9,5 10,2 4,7 7,8 7,8 9,5 9,5 10,2
Input power heating (Nominal) kW 2,02 2,80 3,70 4,74 2,02 2,74 2,80 3,7 3,70 4,74
Input power heating (Min) kW 0,36 0,56 0,58 0,60 0,36 0,56 0,58 0,60
Input power heating (Max) kW 2,85 3,95 5,00 5,80 2,85 3,95 5,00 5,80
Annual energy consumption heating (3) kWh/a 1.400 2.426 1.400 2.324 2.427
Indoor unit S-6071PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-6071PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E
Indoor air flow (Hi) m³/min 21,0 30,0 34,0 35,0 21,0 30,0 30,0 34,0 34,0 35,0
Indoor air flow (Med) m³/min 18,0 25,0 28,0 29,0 18,0 25,0 25,0 28,0 28,0 29,0
Indoor air flow (Lo) m³/min 15,5 23,0 24,0 25,0 15,5 23,0 23,0 24,0 24,0 25,0
Moisture removal volume L/h 2,7 3,6 5,4 6,4 2,7 3,6 3,6 5,4 5,4 6,4
Indoor sound pressure (Med) (4) dB(A) 35 37 40 41 35 37 37 40 40 41
Indoor sound pressure (Lo) (4) dB(A) 30 34 35 36 30 34 34 35 35 36
Indoor sound power (Hi) dB(A) 57 60 64 65 57 60 60 64 64 65
Indoor sound power (Med) dB(A) 53 55 58 59 53 55 55 58 58 59
Indoor sound power (Lo) dB(A) 48 52 53 54 48 52 52 53 53 54
Indoor dimension (Height) mm 235 235 235 235 235 235 235 235 235 235
Indoor dimension (Width) mm 1.275 1.590 1.590 1.590 1.275 1.590 1.590 1.590 1.590 1.590
Indoor dimension (Depth) mm 690 690 690 690 690 690 690 690 690 690
Indoor net weight kg 34 40 40 40 34 40 40 40 40 40
nanoe X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Outdoor unit U-71PZH4E5 U-100PZH4E5 U-125PZH4E5 U-140PZH4E5 U-71PZH4E8 U-100PZH3E8 U-100PZH4E8 U-125PZH3E8 U-125PZH4E8 U-140PZH4E8
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 8,80 11,60 17,10 20,40 2,95 3,80 3,60 5,70 5,45 6,15
Current in cooling (1p 230V / 3p 400) A 8,40 11,10 16,40 19,50 2,80 3,65 3,40 5,40 5,15 5,85
Current in cooling (1p 240V / 3p 415) A 8,05 10,60 15,70 18,70 2,70 3,45 3,25 5,20 5,00 5,65
Current in heating (1p 220V / 3p 380) A 10,20 13,70 18,10 23,20 3,15 4,55 3,75 6,20 5,10 6,20
Current in heating (1p 230V / 3p 400) A 9,75 13,20 17,30 22,20 3,00 4,35 3,55 5,85 4,80 5,90
Current in heating (1p 240V / 3p 415) A 9,35 12,70 16,60 21,20 2,90 4,15 3,40 5,65 4,65 5,65
Outdoor air flow (Cool) m³/min 62,0 76,0 86,0 89,0 62,0 118,0 76,0 125,0 86,0 89,0
Outdoor air flow (Heat) m³/min 66,0 70,0 78,0 83,0 66,0 108,0 70,0 112,0 78,0 83,0
Outdoor sound pressure (Cool -Hi) dB(A) 48 52 55 56 48 52 52 53 55 56
Outdoor sound pressure (Heat -Hi) dB(A) 50 52 55 56 50 52 52 53 55 56
Outdoor sound power (Cool -Hi) dB(A) 65 69 73 74 65 69 69 70 73 74
Outdoor sound power (Heat -Hi) dB(A) 67 69 73 74 67 69 69 70 73 74
Outdoor dimension (Height) mm 996 996 996 996 996 1.416 996 1.416 996 996
Outdoor dimension (Width) mm 980 980 980 980 980 940 980 940 980 980
Outdoor dimension (Depth) mm 370 370 370 370 370 340 370 340 370 370
Outdoor net weight kg 66 84 86 86 66 98 82 98 84 84
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88) 5/8 (15,88)
Pipe length range m 5 ~ 60 5 ~ 100 5 ~ 100 5 ~ 100 5 ~ 60 5 ~ 85 5 ~ 100 5 ~ 85 5 ~ 100 5 ~ 100
Elevation difference (in/out) (7) m 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 (8) 15 / 30 15 / 30 (8) 15 / 30 15 / 30
Pipe length for additional gas m 30 30 30 30 30 30 30 30 30 30
Additional gas amount g/m 30 40 40 40 30 45 40 45 40 40
Refrigerant (R32) / CO2 Eq. kg / T 1,95 / 1,32 2,70 / 1,82 3,00 / 2,03 3,00 / 2,03 1,95 / 1,32 3,05 / 2,06 2,70 / 1,82 3,05 / 2,06 3,00 / 2,03 3,00 / 2,03
Operating range (Cool - Min) °C -15 -20 (8) -20 (8) -20 (8) -15 -20 -20 (8) -20 -20 (8) -20 (8)
Operating range (Cool - Max) °C +52 +52 +52 +52 +52 +48 (9) +52 +48 (9) +52 +52
Operating range (Heat - Min) °C -20 -20 -20 -20 -20 -20 -20 -20 -20 -20
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24 +24 +24 +24

1) EER and COP calculation is based in accordance to EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηs,c / ηs,h values is calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1m in front of the main body and 1m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
7) Outdoor unit located lower / outdoor unit located higher.
8) Pipe length up to 30m.

* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.