PACi NX Series Elite 4 way 60x60 cassette Inverter+ - R32

4 way 60x60 cassette - PY3

From 3,6 to 6,0 kW (3 capacity sizes).

Chassis dimensions (H x W x D): 243 x 575 x 575 mm.

SEER/SCOP class A++*.

Built-in drain pump.


* SCOP class A+ in case of 3,6 and 5,0 kW.

Compact and stylish design.
Ceiling depth is only 250 mm
Exposed area is only 30 mm

Industry-leading energy efficiency.
Achieved SEER/SCOP class A++*.
* SCOP class A+ in case of 3,6 and 5,0 kW.

Individual flap control.
Better control of the air flow with 4 motors.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Elite 4 way 60x60 cassette Inverter+ - R32 SINGLE PHASE
3.6 kW
Kit KIT-36PY3ZH5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 3,6
Cooling capacity (Min) kW 1,2
Cooling capacity (Max) kW 4,0
EER (Nominal) (1) W/W 4,50
EER (Min) (1) W/W 4,04
EER (Max) (1) W/W 5,45
SEER (2) 7,3 A++
Pdesign (cooling) kW 3,6
Input power cooling (Nominal) kW 0,80
Annual energy consumption cooling (3) kWh/a 400
Input power cooling (Min) kW 0,22
Input power cooling (Max) kW 0,99
Annual energy consumption cooling (3) kWh/a 400
Heating capacity (Nominal) kW 4,0
Heating capacity (Min) kW 1,2
Heating capacity (Max) kW 5,0
COP (Nominal) (1) W/W 4,12
COP (Min) (1) W/W 3,45
COP (Max) (1) W/W 5,45
SCOP (2) 4,7 A++
Pdesign at -10°C kW 3,6
Input power heating (Nominal) kW 0,97
Input power heating (Min) kW 0,22
Input power heating (Max) kW 1,45
Annual energy consumption heating (3) kWh/a 1.073
Indoor unit S-36PY3E
Indoor air flow (Hi) m³/min 9,5
Indoor air flow (Med) m³/min 7,5
Indoor air flow (Lo) m³/min 6,0
Moisture removal volume L/h 1,5
Indoor sound pressure (Med) (4) dB(A) 30
Indoor sound pressure (Lo) (4) dB(A) 25
Indoor sound power (Hi) dB(A) 49
Indoor sound power (Med) dB(A) 45
Indoor sound power (Lo) dB(A) 40
Indoor dimension (Height) mm 243
Indoor dimension (Width) mm 575
Indoor dimension (Depth) mm 575
Panel dimension (Height) mm 30
Panel dimension (Depth) mm 625
Indoor net weight kg 15
Panel net weight kg 2,8
nanoe X Generator Mark 2
Outdoor unit U-36PZH3E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 3,95
Current in cooling (1p 230V / 3p 400) A 3,60
Current in cooling (1p 240V / 3p 415) A 3,60
Current in heating (1p 220V / 3p 380) A 4,75
Current in heating (1p 230V / 3p 400) A 4,55
Current in heating (1p 240V / 3p 415) A 4,35
Outdoor air flow (Cool) m³/min 34,1
Outdoor air flow (Heat) m³/min 36,4
Outdoor sound pressure (Cool -Hi) dB(A) 43
Outdoor sound pressure (Heat -Hi) dB(A) 44
Outdoor sound power (Cool -Hi) dB(A) 62
Outdoor sound power (Heat -Hi) dB(A) 64
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 42
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (5) m 15 / 30
Pipe length for additional gas m 30
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,13 / 0,76
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24
Kit KIT-36PY3ZH5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 3,6
Cooling capacity (Min) kW 1,2
Cooling capacity (Max) kW 4,0
EER (Nominal) (1) W/W 4,50
EER (Min) (1) W/W 4,04
EER (Max) (1) W/W 5,45
SEER (2) 7,3 A++
Pdesign (cooling) kW 3,6
Input power cooling (Nominal) kW 0,80
Input power cooling (Min) kW 0,22
Input power cooling (Max) kW 0,99
Annual energy consumption cooling (3) kWh/a 400
Heating capacity (Nominal) kW 4,0
Heating capacity (Min) kW 1,2
Heating capacity (Max) kW 5,0
COP (Nominal) (1) W/W 4,12
COP (Min) (1) W/W 3,45
COP (Max) (1) W/W 5,45
SCOP (2) 4,7 A++
Pdesign at -10°C kW 3,6
Input power heating (Nominal) kW 0,97
Input power heating (Min) kW 0,22
Input power heating (Max) kW 1,45
Annual energy consumption heating (3) kWh/a 1.073
Indoor unit S-36PY3E
Indoor air flow (Hi) m³/min 9,5
Indoor air flow (Med) m³/min 7,5
Indoor air flow (Lo) m³/min 6,0
Moisture removal volume L/h 1,5
Indoor sound pressure (Med) (4) dB(A) 30
Indoor sound pressure (Lo) (4) dB(A) 25
Indoor sound power (Hi) dB(A) 49
Indoor sound power (Med) dB(A) 45
Indoor sound power (Lo) dB(A) 40
Indoor dimension (Height) mm 243
Indoor dimension (Width) mm 575
Indoor dimension (Depth) mm 575
Panel dimension (Height) mm 30
Panel dimension (Depth) mm 625
Indoor net weight kg 15
Panel net weight kg 2,8
nanoe X Generator Mark 2
Outdoor unit U-36PZH3E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 3,95
Current in cooling (1p 230V / 3p 400) A 3,60
Current in cooling (1p 240V / 3p 415) A 3,60
Current in heating (1p 220V / 3p 380) A 4,75
Current in heating (1p 230V / 3p 400) A 4,55
Current in heating (1p 240V / 3p 415) A 4,35
Outdoor air flow (Cool) m³/min 34,1
Outdoor air flow (Heat) m³/min 36,4
Outdoor sound pressure (Cool -Hi) dB(A) 43
Outdoor sound pressure (Heat -Hi) dB(A) 44
Outdoor sound power (Cool -Hi) dB(A) 62
Outdoor sound power (Heat -Hi) dB(A) 64
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 42
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (7) m 15 / 30 (8)
Pipe length for additional gas m 30
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,13 / 0,76
Operating range (Cool - Min) °C -15
Operating range (Cool - Max) °C +46
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

1) EER and COP calculation is based in accordance with EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values are calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
7) When installing the outdoor unit at a higher position than the indoor unit.
8) Outdoor unit located lower / outdoor unit located higher.
* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.
*** Available in Autumn 2021.
**** Tentative data.