PACi NX Elite from 7,1 to 14,0kW R32
Up to 4 indoor units can be connected to the same outdoor unit. Panasonic’s Elite units 7,1, 10,0, 12,0 and 14,0 can be installed as twin, triple and double-twin systems. The indoor units can be combined as per the selection table. The operation will always be simultaneous. All the indoor units will work with the same settings.
Specifications
PACi NX Elite from 7,1 to 14,0kW R32 | ||||||
---|---|---|---|---|---|---|
7.1 kW | 9.5 kW | 12.5 kW | 13.4 kW | |||
Outdoor unit single phase | U-71PZH4E5 | U-100PZH4E5 | U-125PZH4E5 | U-140PZH4E5 | ||
Outdoor unit three phase | U-71PZH4E8 | U-100PZH4E8 | U-125PZH4E8 | U-140PZH4E8 | ||
Cooling capacity (Nominal) | kW | 7,1 | 9,5 | 12,5 | 13,4 | |
Cooling capacity (Min) | kW | 2,2 | 3,1 | 3,2 | 3,3 | |
Cooling capacity (Max) | kW | 9 | 12,5 | 14 | 16 | |
Heating capacity (Nominal) | kW | 8 | 11,2 | 14 | 16 | |
Heating capacity (Min) | kW | 2 | 3,1 | 3,2 | 3,3 | |
Heating capacity (Max) | kW | 9 | 14 | 16 | 18 | |
Power supply (Single phase) | V | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | |
Power supply (Three phase) | V | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | |
Outdoor connection indoor / outdoor | mm² | 2x1,5 or 2,5 | 2x1,5 or 2,5 | 2x1,5 or 2,5 | 2x1,5 or 2,5 | |
Air flow (Cool Hi) | m³/min | 62 | 76 | 86 | 89 | |
Air flow (Heat Hi) | m³/min | 66 | 70 | 78 | 83 | |
Outdoor sound pressure (Cool -Hi) | dB(A) | 48 | 52 | 55 | 56 | |
Outdoor sound pressure (Heat -Hi) | dB(A) | 50 | 52 | 55 | 56 | |
Outdoor sound power (Cool -Hi) | dB(A) | 65 | 69 | 73 | 74 | |
Outdoor sound power (Heat -Hi) | dB(A) | 67 | 69 | 73 | 74 | |
Outdoor dimension (Height) | mm | 996 | 996 | 996 | 996 | |
Outdoor dimension (Width) | mm | 980 | 980 | 980 | 980 | |
Outdoor dimension (Depth) | mm | 370 | 370 | 370 | 370 | |
Net weight | kg | 66 | 84 / 82 | 86 / 84 | 86 / 84 | |
Pipe diameter (Liquid) | Inch (mm) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | |
Pipe diameter (Gas) | Inch (mm) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | |
Pipe length range | m | 5 ~ 60 | 5 ~ 100 | 5 ~ 100 | 5 ~ 100 | |
Elevation difference (in/out) | m | 15 / 30 (2) | 15 / 30 (2) | 15 / 30 (2) | 15 / 30 (2) | |
Pipe length for additional gas | m | 30 | 30 | 30 | 30 | |
Additional gas amount | g/m | 30 | 40 | 40 | 40 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,95 / 1,32 | 2,70 / 1,82 | 3,00 / 2,03 | 3,00 / 2,03 | |
Operating range (Cool - Min) | °C | -15 | -20 (3) | -20 (3) | -20 (3) | |
Operating range (Cool - Max) | °C | 52 | 52 | 52 | 52 | |
Operating range (Heat - Min) | °C | -20 | -20 | -20 | -20 | |
Operating range (Heat - Max) | °C | 24 | 24 | 24 | 24 |
1) Cooling and heating capacity with 4 way 90x90 cassette.
2) Outdoor unit located lower / outdoor unit located higher.
3) Pipe length up to 30m.