Big PACi NX high static pressure hide-away 20,0-25,0kW · R32

The PAC NX Elite range has been expanded to include the Big PACi NX models 20,0‑25,0 kW.

· Highly efficient with compact indoor body
· Split-able Hide Away indoor design for easy & flexible piping work
· nanoe™ X (Generator Mark 3 = 48 trillion hydroxyl radicals/sec) as standard
· The compact outdoor unit with one fan will fit in limited installation space
· Long piping allowance maximum 100m
· Extended operation range up to 52°C in cooling and down to -20°C in heating
· Demand response compliant as a standard function

Specifications

See all
Big PACi NX high static pressure hide-away 20,0-25,0kW · R32 THREE PHASE
20.0 kW 25.0 kW
Kit KIT-200PE4ZH8 KIT-250PE4ZH8
Remote controller CZ-RTC5B CZ-RTC5B
Cooling capacity (Nominal) kW 19,0 22,0
Cooling capacity (Min) kW 5,7 6,1
Cooling capacity (Max) kW 20,0 25,6
EER (Nominal) (1) W/W 3,20 2,74
EER (Min) (1) W/W 2,78 2,49
EER (Max) (1) W/W 4,60 4,88
SEER/ηsc (2) % 237,8% 213,0%
Pdesign (cooling) kW 19,0 22,0
Input power cooling (Nominal) kW 5,93 8,04
Input power cooling (Min) kW 1,24 1,25
Input power cooling (Max) kW 7,20 10,30
Heating capacity (Nominal) kW 22,4 24,0
Heating capacity (Min) kW 5,0 5,5
Heating capacity (Max) kW 24,5 27,6
COP (Nominal) (1) W/W 3,55 3,55
COP (Min) (1) W/W 3,27 3,07
COP (Max) (1) W/W 4,76 4,78
SCOP/ηsc (2) % 146,0% 145,0%
Pdesign at -10°C kW 16,0 17,2
Input power heating (Nominal) kW 6,31 6,76
Input power heating (Min) kW 1,05 1,15
Input power heating (Max) kW 7,50 9,00
Indoor unit S-200PE4E S-250PE4E
External static pressure at shipment (adjustable) Pa 75 (3) (120 / 180) 75 (3) (130 / 200)
Air flow (Hi) m³/min 72 84
Air flow (Med) m³/min 63 72
Air flow (Lo) m³/min 53 59
Indoor sound pressure (Med) (4) dB(A) 44 45
Indoor sound pressure (Lo) (4) dB(A) 41 42
Indoor dimension (Height) mm 486 486
Indoor dimension (Width) mm 1456 1456
Indoor dimension (Depth) mm 916 916
Indoor net weight kg 83 87
Outdoor unit U-200PZH4E8 U-250PZH4E8
Outdoor recommended fuse A 30 30
Outdoor air flow (Cool) m³/min 116 116
Outdoor air flow (Heat) m³/min 136 148
Outdoor sound pressure (Cool -Hi) dB(A) 57 57
Outdoor sound pressure (Heat -Hi) dB(A) 61 63
Outdoor sound power (Cool -Hi) dB(A) 76 76
Outdoor sound power (Heat -Hi) dB(A) 80 82
Outdoor dimension (Height) (5) mm 996 996
Outdoor dimension (Width) (5) mm 1 140 1 140
Outdoor dimension (Depth) (5) mm 460 460
Outdoor net weight kg 109 109
Pipe diameter (Liquid) Inch (mm) 1/2 (12,7) 1/2 (12,7)
Pipe diameter (Gas) Inch (mm) 7/8 (22,22) 7/8 (22,22)
Pipe length range m 5 ~ 100 5 ~ 100
Elevation difference (in/out) m 30 30
Pipe length for additional gas m 30 30
Additional gas amount g/m 80 80
Refrigerant (R32) / CO2 Eq. kg / T 4,8 / 3,24 4,8 / 3,24
Operating range (Cool - Min) °C -15 -15
Operating range (Cool - Max) °C +52 +52
Operating range (Heat - Min) °C -20 -20
Operating range (Heat - Max) °C +35 +35

1) EER and COP calculation is based in accordance to EN14511.
2) For models above 12kW, the ηs,c / ηs,h values is calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Add 100mm for indoor unit or 70mm for outdoor unit for piping port.