T-CAP stand-alone outdoor M Series with control module 1 phase - 3 phase · R290
Aquarea M Series, the latest generation of Aquarea air to water heat pumps with R290
Aquarea T-CAP M Series delivers a revolution in the design, performance, connectivity, and sustainability
The solution is suitable for both new buildings and retrofits, as it offers a sustainable alternative to traditional fossil fuel heating systems and it can be easily integrated with existing water system such as fan coils, floor heating or domestic hot water tanks.
- Up to 75°C water outlet down to -15°C outdoor 1)
- Quiet operation: Only 29dB(A) sound pressure at 5m 2)
- Reliable outdoor units with Panasonic compressor, operating down to -28°C outdoor 3)
- T-CAP technology: Keeping heating capacity down to -20°C
- Panasonic Comfort Cloud App and Aquarea Service Cloud included
- 2 CN-CNT connectivity ports
- Control module for enhanced functionality
- Possibility to control a field supply back-up heater
1) Down to 15ºC outdoor for 20, 25 and 30kW models
2) Sound pressure calculation for WH-WXG12ME5, free standing, A +7°C, W 35°C in Quite mode 3
3) Down to -25ºC outdoor for 20, 25 and 30kW models
Specifications
T-CAP stand-alone outdoor M Series with control module 1 phase - 3 phase · R290 | |||
---|---|---|---|
9 kW | |||
Outdoor unit | WH-WXG09ME8 | ||
Heating capacity (A +7°C, W 35°C) | kW | 9,00 | |
COP (A +7°C, W 35°C) | 5,23 | ||
Heating capacity (A +7°C, W 55°C) | kW | 9,00 | |
COP (A +7°C, W 55°C) | 3,24 | ||
Heating capacity (A +2°C, W 35°C) | kW | 9,00 | |
COP (A +2°C, W 35°C) | 3,81 | ||
Heating capacity (A +2°C, W 55°C) | kW | 9,00 | |
COP (A +2°C, W 55°C) | 2,54 | ||
Heating capacity (A -7°C, W 35°C) | kW | 9,00 | |
COP (A -7°C, W 35°C) | 3,45 | ||
Heating capacity (A -7°C, W 55°C) | kW | 9,00 | |
COP (A -7°C, W 55°C) | 2,35 | ||
Cooling capacity (A 35°C, W 7°C) | kW | 9,00 | |
EER (A 35°C, W 7°C) | 3,61 | ||
Cooling capacity (A 35°C, W 18°C) | kW | 9,00 | |
EER (A 35°C, W 18°C) | 5,26 | ||
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,96 / 3,57 | |
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 195 / 140 | |
Heating average climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A++ | |
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 6,47 / 4,34 | |
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 256 / 171 | |
Heating warm climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A+++ / A+++ | |
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | SCOP | 4,31 / 3,26 | |
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) | ηs % | 169/127 | |
Heating cold climate. Energy class (W 35°C / W 55°C) (1) | A+++ to D | A++ / A++ | |
Outdoor dimension (Height) | mm | 1.520 | |
Outdoor dimension (Width) | mm | 1.200 | |
Outdoor dimension (Depth) | mm | 430 | |
Outdoor net weight | kg | 161 | |
A class pump (Number of speeds) | Variable speed | ||
A class pump (Input power Min) | W | 30 | |
A class pump (Input power Max) | W | 175 | |
Heating water flow (∆T=5 K. 35°C) | L/min | 25,8 | |
Operation range - Outdoor ambient (Heat) | °C | -28 ~ +35 | |
Operation range - Outdoor ambient (Cool) | °C | +10 to +43 | |
Water outlet (Heat) | °C | 25 to 75 | |
Water outlet (Cool) | °C | 5 to 20 | |
Indoor dimension (Height) | mm | 450 | |
Indoor dimension (Width) | mm | 450 | |
Indoor dimension (Depth) | mm | 117 | |
Indoor net weight | kg | 7 |
(1) Scale from A+++ to D.
(2) Sound power level in accordance to EN12102 under conditions of the EN14825.
(3) WH-WXG models are hermetically sealed.
(4) Check local regulations.
* EER and COP classification is at 230V only in accordance with EU directive 2003/32/EC.