Aquarea High Performance Mono‑bloc J Generation 1 Phase • R32

Aquarea, an innovative new low-energy system based on Air to Water heat pump technology


Aquarea warms your home effectively and efficiently, even with extreme outdoor temperatures. Aquarea can also cool space in summer and bring hot water all year round.
Aquarea High Performance is the range for new installations and low consumption homes. Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
The Mono‑Bloc system: This only has an outdoor unit. The installation doesn’t require a refrigerated connection and is only connected to the heating and/or hot water.

Why make the switch to a heat pump?

Specifications

See all
Aquarea High Performance Mono‑bloc J Generation 1 Phase • R32
5 kW
Heating capacity (A +7°C, W 35°C) kW 5,00
COP (A +7°C, W 35°C) 5,08
Heating capacity (A +7°C, W 55°C) kW 5,00
COP (A +7°C, W 55°C) 3,01
Heating capacity (A +2°C, W 35°C) kW 5,00
COP (A +2°C, W 35°C) 3,57
Heating capacity (A +2°C, W 55°C) kW 5,00
COP (A +2°C, W 55°C) 2,27
Heating capacity (A -7°C, W 35°C) kW 5,00
COP (A -7°C, W 35°C) 2,78
Heating capacity (A -7°C, W 55°C) kW 5,00
COP (A -7°C, W 55°C) 1,85
Cooling capacity (A 35°C, W 7°C) kW 5,00
EER (A 35°C, W 7°C) 3,31
Cooling capacity (A 35°C, W 18°C) kW 5,00
EER (A 35°C, W 18°C) 5,05
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 202 / 142
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,12 / 3,63
Heating average climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 237 / 165
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,00 / 4,20
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 160 / 115
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,08 / 2,95
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A+
Outdoor sound power part load (Heat) (1) dB(A) 59
Outdoor sound power full load (Heat) dB(A) 64
Outdoor sound power full load (Cool) dB(A) 65
Outdoor dimension (Height) mm 865
Outdoor dimension (Width) mm 1283
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 99
Refrigerant (R32) / CO2 Eq. (2) kg / T 1,3 / 0,878
Water pipe connector Inch R 1¼
Pump (Number of speeds) Variable Speed
Pump (Input power Min) W 34
Pump (Input power Max) W 96
Heating water flow (∆T=5 K. 35°C) L/min 14,30
Capacity of integrated electric heater kW 3
Input power (Heat) kW 0,99
Input power (Cool) kW 1,51
Running and starting current (Heat) A 4,7
Running and starting current (Cool) A 7,0
Current 1 A 12,0
Current 2 A 13
Indoor recommended fuse A 30 / 15
Recommended cable size, supply 1 mm² 3 x 1,5
Recommended cable size, supply 2 mm² 3 x 1,5
Operation range - outdoor temperature (Heat) °C -20 ~ 35
Operation range - outdoor temperature (Cool) °C 10 ~ 43
Water outlet (Heat) °C 20 ~ 60
Water outlet (Cool) °C 5 ~ 20

(1) Sound power in accordance to 8112013,81312013 and EN12102-1:2017 at +7°C.
(2) WH-MDC models are hermetically sealed.
EER and COP calculation is based in accordance to EN14511.

Complementary products