PACi NX Series Standard wall-mounted Inverter+ - R32

The wall-mounted units with stylish matt colour can be offered for many applications such as studios, gyms, high ceiling areas and even computer server rooms.

The compact design and flat face ensure discreet installation, even in a small space.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Standard wall-mounted Inverter+ - R32
6.0 kW
Kit KIT-60PK3Z5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 6,1
Cooling capacity (Min) kW 2,0
Cooling capacity (Max) kW 7,1
EER (Nominal) (1) W/W 3,67
SEER (2) 7,0 A++
Pdesign (cooling) kW 6,1
Input power cooling (Nominal) kW 1,66
Annual energy consumption cooling (3) kWh/a 3,05
Heating capacity (Nominal) kW 6,1
Heating capacity (Min) kW 1,8
Heating capacity (Max) kW 7,0
COP (Nominal) (1) W/W 4,39
SCOP (2) 4,7 A++
Pdesign at -10°C kW 4,6
Input power heating (Nominal) kW 1,39
Annual energy consumption heating (3) kWh/a 1.370
Indoor unit S-6010PK3E
Indoor air flow (Hi) m³/min 20,0
Indoor air flow (Med) m³/min 17,5
Indoor air flow (Lo) m³/min 14,5
Moisture removal volume L/h 2,0
Indoor sound pressure (Med) (4) dB(A) 44
Indoor sound pressure (Lo) (4) dB(A) 40
Indoor sound power (Hi) dB(A) 63
Indoor sound power (Med) dB(A) 60
Indoor sound power (Lo) dB(A) 56
Indoor dimension (Height) mm 302
Indoor dimension (Width) mm 1.120
Indoor dimension (Depth) mm 236
Indoor net weight kg 14
nanoe X Generator Mark 2
Outdoor unit U-60PZ3E5A
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 7,70
Current in cooling (1p 230V / 3p 400) A 7,35
Current in cooling (1p 240V / 3p 415) A 7,05
Current in heating (1p 220V / 3p 380) A 6,45
Current in heating (1p 230V / 3p 400) A 6,15
Current in heating (1p 240V / 3p 415) A 5,90
Outdoor air flow (Cool) m³/min 42,6
Outdoor air flow (Heat) m³/min 41,5
Outdoor sound pressure (Cool -Hi) dB(A) 47
Outdoor sound pressure (Heat -Hi) dB(A) 48
Outdoor sound power (Cool -Hi) dB(A) 64
Outdoor sound power (Heat -Hi) dB(A) 65
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 42
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) (5)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) (6)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (7) m 15 / 30 (8)
Pipe length for additional gas m 30
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,15 / 0,78
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

1) EER and COP calculation is based in accordance with EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values are calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1m in front of the main body and 1m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
7) When installing the outdoor unit at a higher position than the indoor unit.
8) Outdoor unit located lower / outdoor unit located higher.
* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.