PACi NX Series Elite ceiling Inverter+ - R32

Ceiling mounted units provide large and wide air distribution which is good for big rooms

The height and depth of all capacities are the same for unified appearance in mixed installations.

The next generation of commercial air conditioners is here

Specifications

See all
PACi NX Series Elite ceiling Inverter+ - R32
12.5 kW
Kit KIT-125PT3ZH8
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 12,1
Cooling capacity (Min) kW 3,2
Cooling capacity (Max) kW 14,0
EER (Nominal) (1) W/W 3,51
SEER/ηsc (2) % 277,3 %
Pdesign (cooling) kW 12,1
Input power cooling (Nominal) kW 3,45
Annual energy consumption cooling (3) kWh/a
Heating capacity (Nominal) kW 14,0
Heating capacity (Min) kW 3,2
Heating capacity (Max) kW 16,0
COP (Nominal) (1) W/W 3,78
SCOP/ηsc (2) % 180,9 %
Pdesign at -10°C kW 9,5
Input power heating (Nominal) kW 3,7
Annual energy consumption heating (3) kWh/a
Indoor unit S-1014PT3E
Indoor air flow (Hi) m³/min 34,0
Indoor air flow (Med) m³/min 28,0
Indoor air flow (Lo) m³/min 24,0
Moisture removal volume L/h 5,4
Indoor sound pressure (Med) (4) dB(A) 40
Indoor sound pressure (Lo) (4) dB(A) 35
Indoor sound power (Hi) dB(A) 64
Indoor sound power (Med) dB(A) 58
Indoor sound power (Lo) dB(A) 53
Indoor dimension (Height) mm 235
Indoor dimension (Width) mm 1.590
Indoor dimension (Depth) mm 690
Indoor net weight kg 40
nanoe X Generator Mark 2
Outdoor unit U-125PZH3E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 5,70
Current in cooling (1p 230V / 3p 400) A 5,40
Current in cooling (1p 240V / 3p 415) A 5,20
Current in heating (1p 220V / 3p 380) A 6,20
Current in heating (1p 230V / 3p 400) A 5,85
Current in heating (1p 240V / 3p 415) A 5,65
Outdoor air flow (Cool) m³/min 125,0
Outdoor air flow (Heat) m³/min 112,0
Outdoor sound pressure (Cool -Hi) dB(A) 53
Outdoor sound pressure (Heat -Hi) dB(A) 53
Outdoor sound power (Cool -Hi) dB(A) 70
Outdoor sound power (Heat -Hi) dB(A) 70
Outdoor dimension (Height) mm 1.416
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Outdoor net weight kg 98
Pipe diameter (Liquid) Inch (mm) 3/8 (9,52)
Pipe diameter (Gas) Inch (mm) 5/8 (15,88)
Pipe length range m 5 ~ 85
Elevation difference (in/out) (7) m 15 / 30 (8)
Pipe length for additional gas m 30
Additional gas amount g/m 45
Refrigerant (R32) / CO2 Eq. kg / T 3,05 / 2,06
Operating range (Cool - Min) °C -20
Operating range (Cool - Max) °C +48 (9)
Operating range (Heat - Min) °C -20
Operating range (Heat - Max) °C +24

1) EER and COP calculation is based in accordance to EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηs,c / ηs,h values is calculated based on EN 14825.
3) Factory setting.
4) The sound pressure of the units shows the value measured of the position 1m in front of the main body and 1m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
5) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
6) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit.
7) Outdoor unit located lower / outdoor unit located higher.
8) Pipe length up to 30m.

* Recommended fuse for the indoor 3A.
** Above values are in the case of nanoe™ X OFF.

Complementary products