PACi NX Series Elite adaptive ducted unit Inverter+ - R32
Design duct range PF3
2 installation possibilities (horizontal / vertical) with high ESP 150Pa allows flexible installation.
- 2 installation possibilities (horizontal / vertical)
- Maximum external static pressure: 150 Pa
- Selectable inlet air position (rear / bottom entry)
- Improved drain pan suitable for both horizontal / vertical installation
- Drain pump included
- nanoe™ X (Generator Mark 2= 9,6 trillion hydroxyl radicals/sec) as standard for the long duct piping case*
- Wired remote control CZ-RTC6WBL and CZ-RTC6BL allows easy system setting via Bluetooth®
* The performance of nanoe™ X air can be expected even by 10m long duct by Panasonic internal survey.
The next generation of commercial air conditioners is here
New adaptive ducted PF3
The next generation of commercial air conditioners is here
Specifications
PACi NX Series Elite adaptive ducted unit Inverter+ - R32 | |||
---|---|---|---|
12.5 kW | |||
Kit | KIT-125PF3ZH45 | ||
Remote controller | CZ-RTC5B | ||
Cooling capacity (Nominal) | kW | 12,1 | |
Cooling capacity (Min) | kW | 3,2 | |
Cooling capacity (Max) | kW | 13,6 | |
EER (Nominal) (1) | W/W | 3,53 | |
EER (Min) (1) | W/W | 3,00 | |
EER (Max) (1) | W/W | 5,00 | |
SEER/ηsc (2) | % | 281,7% | |
Pdesign (cooling) | kW | 12,1 | |
Input power cooling (Nominal) | kW | 3,43 | |
Input power cooling (Min) | kW | 0,64 | |
Input power cooling (Max) | kW | 4,54 | |
Annual energy consumption cooling (3) | kWh/a | — | |
Heating capacity (Nominal) | kW | 13,5 | |
Heating capacity (Min) | kW | 3,2 | |
Heating capacity (Max) | kW | 15,4 | |
COP (Nominal) (1) | W/W | 3,46 | |
COP (Min) (1) | W/W | 3,06 | |
COP (Max) (1) | W/W | 5,16 | |
SCOP/ηsc (2) | % | 165,0% | |
Pdesign at -10°C | kW | 9,3 | |
Input power heating (Nominal) | kW | 3,90 | |
Input power heating (Min) | kW | 0,62 | |
Input power heating (Max) | kW | 5,04 | |
Annual energy consumption heating (3) | kWh/a | — | |
Indoor unit | S-1014PF3E | ||
External static pressure (Nominal) (4) | Pa | 50 | |
External static pressure (Min) (4) | Pa | 10 | |
External static pressure (Max) (4) | Pa | 150 | |
Moisture removal volume | L/h | 34,0 | |
Indoor air flow (Hi) | m³/min | 29,0 | |
Indoor air flow (Med) | m³/min | 23,0 | |
Indoor air flow (Lo) | m³/min | 4,1 | |
Indoor sound pressure (Hi) (5) | dB(A) | 35 | |
Indoor sound pressure (Med) (5) | dB(A) | 31 | |
Indoor sound pressure (Lo) (5) | dB(A) | 27 | |
Indoor sound power (Hi) | dB(A) | 58 | |
Indoor sound power (Med) | dB(A) | 54 | |
Indoor sound power (Lo) | dB(A) | 50 | |
Indoor dimension (Height) | mm | 250 | |
Indoor dimension (Width) | mm | 1.400 | |
Indoor dimension (Depth) | mm | 730 | |
Indoor net weight | kg | 39 | |
nanoe X Generator | Mark 2 | ||
Outdoor unit | U-125PZH4E5 | ||
Outdoor power source | V | 220 - 230 - 240 | |
Current in cooling (1p 220V / 3p 380) | A | 16,80 | |
Current in cooling (1p 230V / 3p 400) | A | 16,00 | |
Current in cooling (1p 240V / 3p 415) | A | 15,40 | |
Current in heating (1p 220V / 3p 380) | A | 19,10 | |
Current in heating (1p 230V / 3p 400) | A | 18,20 | |
Current in heating (1p 240V / 3p 415) | A | 17,50 | |
Outdoor air flow (Cool) | m³/min | 86,0 | |
Outdoor air flow (Heat) | m³/min | 78,0 | |
Outdoor sound pressure (Cool -Hi) | dB(A) | 55 | |
Outdoor sound pressure (Heat -Hi) | dB(A) | 55 | |
Outdoor sound power (Cool -Hi) | dB(A) | 73 | |
Outdoor sound power (Heat -Hi) | dB(A) | 73 | |
Outdoor dimension (Height) | mm | 996 | |
Outdoor dimension (Width) | mm | 980 | |
Outdoor dimension (Depth) | mm | 370 | |
Outdoor net weight | kg | 86 | |
Pipe diameter (Liquid) | Inch (mm) | 3/8 (9,52) | |
Pipe diameter (Gas) | Inch (mm) | 5/8 (15,88) | |
Pipe length range | m | 5 ~ 100 | |
Elevation difference (in/out) (8) | m | 15 / 30 | |
Pipe length for additional gas | m | 30 | |
Additional gas amount | g/m | 40 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 3,00 / 2,03 | |
Operating range (Cool - Min) | °C | -20 (9) | |
Operating range (Cool - Max) | °C | +52 | |
Operating range (Heat - Min) | °C | -20 | |
Operating range (Heat - Max) | °C | +24 |
1) EER and COP calculation is based in accordance to EN14511.
2) For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηs,c / ηs,h values is calculated based on EN 14825.
3) Factory setting.
4) Medium external static pressure setting from factory.
5) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
6) Connect the liquid socket tube (Ø6,35-Ø9,52) to the liquid tubing side indoor unit.
7) Connect the gas socket tube (Ø12,70-Ø15,88) to the gas tubing side indoor unit. 8) Outdoor unit located lower / outdoor unit located higher.
9) Pipe length up to 30m.
* Recommended fuse for the indoor 3A.
** Above values are in the case of standard installation(horizontal installation in the celling, rear side air intake) and nanoe™ X OFF.