Individual control systems
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CZ_RT1.jpg)
- Remote controller with LCD and self-diagnosis
- Constant monitoring of the system with fault detection
- Weekly timer function
- Maintenance time and cost reduction
- ON/OFF
- Real time daily timer
- Weekly timer: 6 actions per day (total 42 actions per week), including temperature setting.
- Temperature adjustment
- Adjusting air direction
- Selection of operating mode
- Fan speed control
- Restart filter
- Ventilation interlink
- Operating mode
- Centralised control indicator
- Demand control indicator
- Operation priority indicator
- Selected temperature
- Air direction
- Clock
- Day of the week indicator
- Inspection/operating test
- Fan speed
- Filter maintenance
- Defrost/hot start indicator
- Error mode display
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CTRL_Individual_Control_FSM_1.jpg)
Weekly timer setting (each day of the week) is available to control the air conditioner. Max. 6 settings/day and 42 settings/week can be executed. The setting temperature can also be programmed for optimal comfort.
Examples of setting weekly timer
Example: Closed Saturday afternoon and all day Sunday.
Mon-Fri On 9:00, Off 18:00
Sat On 9:00, Off 12:00
Sun Not set
The timer can have different settings for every day of the week.
Example: Set a lower temperature at lunch time when many people may visit.
Everyday
On 12:00 23 °C
On 14:00 28 °C
In this case, the temperature can be set at the same time.
Example: To prevent forgetting to switch OFF weekdays
Mon-Fri
Off 20:00
The timer can be set for simple shut-off operation.
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CTRL_Individual_Control_FSM_2.jpg)
1 Select the day
2 Enter the time
* Simple Timer Mode
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CTRL_Individual_Control_FSM_3.jpg)
When an external device such as a ventilator is connected to the indoor unit, switch ON/OFF of the ventilator can be controlled by the wired remote control. Either link-ventilation or independent-ventilation is selectable.
Energy recovery ventilators are also offered by Panasonic.
Optional printed circuit board (Interface Adapter for External Signals: CZ-TA31P*) is needed.
A. Digital connection
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CZ_TA30P.jpg)
- By connecting to the indoor unit, a separately sold ventilator can be controlled.
- Remote control operation of the indoor unit is enabled (ON/OFF control).
- The operating condition of the indoor unit (malfunctions, operating status) can be externally output.
- Control in linkage with a Energy Recovery Ventilators (ERV) or similar is possible.
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CTRL_Individual_Control_FSM_4.jpg)
- Remote ON/OFF
- Remote /Local Selection
- ON/OFF Monitor Signal
- Malfunction Signal
- Fan Operation Signal
B. Digital connection
C. Central control system (local supply)
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CZ_RWS1-C1.jpg)
- Remote controller with LCD and self-diagnosis
- Error code recognition
- Maintenance time and cost reduction
- Real time daily timer
Operating buttons
- ON/OFF
- Activate/deactivate programmer
- Real time daily timer
- Temperature adjustment
- Air direction
- Operating mode
- Fan speed control
- Restart filter
- Inspection of error code
Monitor
- Operating mode
- Temperature selected
- Air direction
- Time programming
- Error code display
- Fan speed
- Clock
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CZ_RWRU1-RM1.jpg)
Wireless receivers for wall-mounted and 60x60 Cassette types are equipped as standard.
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CZ_RD1.jpg)
Enables the cooling, heating and ventilating operating mode for each outdoor unit. Allows the operating mode to be changed for several outdoor units at the same time by means of a single remote control.
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CZ_CAP1.jpg)
Control terminal to be connected with outside devices or CZ-RD1 controller.
- Used to receive forced stop digital signal from local procured central control system.
- Used to receive demand control signal from local procured central control system. (Demand control for energy saving with 3-level selection)
- Required to connect with CZ-RD1 cooling/heating controller.
- Group control of several FS Multi VRF systems for forced stop and CZ-RD1 cooling/heating controller.
![](https://www.aircon.panasonic.eu/uploads/__/clima_controls/CTRL_Individual_Control_FSM_5.jpg)
A. Terminal module
B. Terminal block
C. Central control system (local supply) such as Fire Alarm device
A. Terminal block
B. Demand controller
A. Terminal block
A. Further Outdoor unit system
*Not applicable for demand controller