Modelos
Aquarea High Performance Hydraulic Split All in One L Generation Single phase
A revolution in design, efficiency, connectivity and sustainability.Aquarea L Generation is engineered with industry leading R290 natural refrigerant with GWP 3. It is the perfect solution for renovations, where a high water outlet temperature is required or homes looking for avant-garde heat pump with natural refrigerant.
Outstanding efficiency and energy savings with minimised CO2 emissions and minimum space.
A premium white, faithful to the Aquarea spirit underlined by the seamlessly integrated controller which provides a sleek black band across the unit. The All in One model maintains its compactness with its encroachment of only 599 x 602mm, comparable to a household appliance.
The outdoor units, with an Anthracite Grey colour which will dress the entire range, have been completely redesigned with an innovative design that will find its place in all spaces.
- Natural refrigerant R290 with GWP 3
- A+++ in heating at 35°C and A+ in DHW
- DHW up to 65°C without heater
- Stainless steel DHW tank with U-Vacua™ insulation panel
- DHW COP up to 3,60
- Hydraulic connection between indoor and outdoor
- Built-in magnetic water filter
- Installation possible in sites with harsh water quality
- Operation without backup heating at -25°C
- 75°C water outlet temperature maximum at -10°C outside temperature
- 55°C hot water even at -25°C outside temperature
- Optimised user interface and improved features
- Wi-Fi adapter included
¿Tienes un equipo Aquarea?
Especificaciones
Hydraulic Split L Generation 1 phase with Electrical Anode · R290 | MONOFÁSICA | ||||
---|---|---|---|---|---|
5 kW | 7 kW | 9 kW | |||
Capacidad calorífica (aire +7 °C, agua 35 °C) | kW | 5,00 | 7,00 | 9,00 | |
COP (aire +7 °C, agua 35 °C) | 5,05 | 4,93 | 4,55 | ||
Capacidad calorífica (aire +7 °C, agua 55 °C) | kW | 5,00 | 7,00 | 8,90 | |
COP (aire +7 °C, agua 55 °C) | 3,07 | 2,98 | 3,03 | ||
Capacidad calorífica (aire +2 °C, agua 35 °C) | kW | 5,00 | 6,85 | 7,00 | |
COP (aire +2 °C, agua 35 °C) | 3,52 | 3,43 | 3,41 | ||
Capacidad calorífica (aire +2 °C, agua 55 °C) | kW | 5,00 | 6,25 | 7,00 | |
COP (aire +2 °C, agua 55 °C) | 2,34 | 2,34 | 2,41 | ||
Capacidad calorífica (aire -7 °C, agua 35 °C) | kW | 5,00 | 6,25 | 7,00 | |
COP (aire -7 °C, agua 35 °C) | 2,34 | 2,34 | 2,41 | ||
Capacidad calorífica (aire -7 °C, agua 55 °C) | kW | 5,00 | 5,80 | 7,00 | |
COP (aire -7 °C, agua 55 °C) | 3,01 | 3,01 | 2,80 | ||
Capacidad frigorífica (aire 35 °C, agua 7 °C) | kW | 5,00 | 7,00 | 8,20 | |
EER (aire 35 °C, agua 7 °C) | 3,23 | 3,03 | 2,82 | ||
Capacidad frigorífica (aire 35 °C, agua 18 °C) | kW | 5,00 | 7,00 | 9,00 | |
EER (aire 35 °C, agua 18 °C) | 5,00 | 4,73 | 4,19 | ||
Calefacción en clima templado. Eficiencia energética estacional (agua 35 °C / agua 55 °C) | SCOP | 5,06 / 3,63 | 4,96 / 3,62 | 4,84 / 3,67 | |
Calefacción en clima templado. Eficiencia energética estacional (agua 35 °C / agua 55 °C) | ηs % | 200 / 142 | 195 / 142 | 190 / 144 | |
Calefacción en clima templado. Clase energética (agua 35 °C / agua 55 °C) (1) | A+++ to D | A+++ / A++ | A+++ / A++ | A+++ / A++ | |
Calefacción en clima cálido. Eficiencia energética estacional (agua 35 °C / agua 55 °C) | SCOP | 6,00 / 4,27 | 6,31 / 4,52 | 6,44 / 4,50 | |
Calefacción en clima cálido. Eficiencia energética estacional (agua 35 °C / agua 55 °C) | ηs % | 237 / 168 | 249 / 178 | 255 / 177 | |
Calefacción en clima cálido. Clase energética (agua 35 °C / agua 55 °C) (1) | A+++ to D | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | |
Calefacción en clima frío. Eficiencia energética estacional (agua 35 °C / agua 55 °C) | SCOP | 4,25 / 3,28 | 4,25 / 3,29 | 4,31 / 3,33 | |
Calefacción en clima frío. Eficiencia energética estacional (agua 35 °C / agua 55 °C) | ηs % | 167 / 128 | 167 / 129 | 170 / 130 | |
Calefacción en clima frío. Clase energética (agua 35 °C / agua 55 °C) (1) | A+++ to D | A++ / A++ | A++ / A++ | A++ / A++ | |
Presión acústica interior (calor) | dB(A) | 28 | 28 | 28 | |
Presión acústica interior (frío) | dB(A) | 28 | 28 | 28 | |
Dimensiones interiores (alto) | mm | 1.642 | 1.642 | 1.642 | |
Dimensiones de la unidad interior (anchura) | mm | 599 | 599 | 599 | |
Dimensiones de la unidad interior (profundidad) | mm | 602 | 602 | 602 | |
Peso neto unidad interior | kg | 93 (3kW) / 94 (6kW) | 93 (3kW) / 94 (6kW) | 93 (3kW) / 94 (6kW) | |
Bomba clase A (número de velocidades) | Variable Speed | Variable Speed | Variable Speed | ||
Bomba clase A (potencia absorbida mín.) | W | 30 | 30 | 30 | |
Bomba clase A (potencia absorbida máx.) | W | 145 | 145 | 145 | |
Caudal de agua de calefacción (∆T=5 K. 35 °C) | L/min | 14,3 | 20,1 | 25,8 | |
Volumen de agua | L | 185 | 185 | 185 | |
Temperatura máxima del agua | °C | 65 | 65 | 65 | |
Material interior del depósito | Stainless steel | Stainless steel | Stainless steel | ||
Perfil de extracción según EN 16147 | L | L | L | ||
Depósito de ACS ERP clasificación de eficiencia en clima templado 2) | A+ to F | A+ | A+ | A+ | |
Depósito de ACS ERP clasificación de eficiencia en clima cálido 2) | A+ to F | A+ | A+ | A+ | |
Depósito de ACS ERP clasificación de eficiencia en clima frío 2) | A+ to F | A | A | A | |
Depósito de ACS ErP clima templado η | ηwh % | 146 | 146 | 146 | |
Depósito de ACS ErP clima cálido η | ηwh % | 160 | 160 | 160 | |
Depósito de ACS ErP clima frío η | ηwh % | 112 | 112 | 112 | |
Unidad exterior | WH-WDG05LE5 | WH-WDG07LE5 | WH-WDG09LE5 | ||
Dimensiones exteriores (alto) | mm | 996 | 996 | 996 | |
Dimensiones exteriores (anchura) | mm | 980 | 980 | 980 | |
Dimensiones exteriores (profundidad) | mm | 430 | 430 | 430 | |
Peso neto unidad exterior | kg | 98 | 98 | 97 | |
Desnivel (int./ext.) | m | 10 | 10 | 10 | |
Rango de funcionamiento - Condiciones ambientales exteriores (calor) | °C | -25 ~ +35 | -25 ~ +35 | -25 ~ +35 | |
Rango de funcionamiento - Condiciones ambientales exteriores (frío) | °C | +10 ~ +43 | +10 ~ +43 | +10 ~ +43 | |
Salida de agua (calor) | °C | 20 ~ 75 | 20 ~ 75 | 20 ~ 75 | |
Salida de agua (frío) | °C | 5 ~ 20 | 5 ~ 20 | 5 ~ 20 |
(2) Scale from A+ to F.
(3) The sound power level is measured with accordance to EN12102 under conditions of the EN14825 (part load).
(4) Check local regulations.
* EER and COP calculation is based in accordance to EN14511.
** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.