Models
Large capacity PACi. Trusted power and high efficiency.
- High performance turbo fan, path system for heat exchanger
- nanoe™ X that improves indoor air quality
- Econavi: Intelligent sensor to reduce waste of energy
- Datanavi simple support tool App with remote controller (CZ-RTC5B)
- Lower noise in slow fan operation
- Light weight, easy piping
- Drain pump included
Looduslik tasakaal siseruumides
Specifications
PACi Standard 4 Way 90x90 • R32 | SINGLE PHASE | THREE PHASE | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
6.0 kW | 7.1 kW | 10.0 kW | 12.5 kW | 14.0 kW | 10.0 kW | 12.5 kW | 14.0 kW | |||
Kit | KIT-60PU2Z5 | KIT-71PU2Z5 | KIT-100PU2Z5 | KIT-125PU2Z5 | KIT-140PU2Z5 | KIT-100PU2Z8 | KIT-125PU2Z8 | KIT-140PU2Z8 | ||
Remote controller | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | ||
EER (Min) (1) | W/W | 5,36 | 5,33 | 5,32 | 5,36 | 5,33 | 5,32 | |||
EER (Max) (1) | W/W | 2,88 | 2,81 | 2,73 | 2,88 | 2,81 | 2,73 | |||
Annual energy consumption cooling (3) | kWh/a | 276 | 327 | 515 | — | — | 521 | — | — | |
Annual energy consumption cooling (3) | kWh/a | 276 | 327 | 515 | — | — | 521 | — | — | |
COP (Min) (1) | W/W | 3,59 | 3,57 | 3,33 | 3,59 | 3,57 | 3,33 | |||
COP (Max) (1) | W/W | 5,36 | 5,50 | 5,48 | 5,36 | 5,50 | 5,48 | |||
Annual energy consumption heating (3) | kWh/a | 1787 | 1787 | 3182 | — | — | 3182 | — | — | |
Indoor air flow (Hi) | m³/min | 21,0 | 22,0 | 36,0 | 37,0 | 38,0 | 36,0 | 37,0 | 38,0 | |
Indoor air flow (Med) | m³/min | 16,0 | 16,0 | 26,0 | 27,0 | 29,0 | 26,0 | 27,0 | 29,0 | |
Indoor air flow (Lo) | m³/min | 13,0 | 13,0 | 18,0 | 19,0 | 20,0 | 18,0 | 19,0 | 20,0 | |
Moisture removal volume | L/h | 1,7 | 2,5 | 2,7 | 4,8 | 6,0 | 2,7 | 4,8 | 6,0 | |
Indoor sound pressure (Med) (4) | dB(A) | 31 | 31 | 38 | 39 | 40 | 38 | 39 | 40 | |
Indoor sound pressure (Lo) (4) | dB(A) | 28 | 28 | 32 | 33 | 34 | 32 | 33 | 34 | |
Indoor sound power (Hi) | dB(A) | 51 | 52 | 60 | 61 | 62 | 60 | 61 | 62 | |
Indoor sound power (Med) | dB(A) | 46 | 46 | 53 | 54 | 55 | 53 | 54 | 55 | |
Indoor sound power (Lo) | dB(A) | 43 | 43 | 47 | 48 | 49 | 47 | 48 | 49 | |
nanoe X Generator | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | Mark 1 | ||
Outdoor power source | V | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | |
Current in cooling (1p 220V / 3p 380) | A | 7,40 | 9,95 | 12,10 | 16,30 | 20,40 | 4,10 | 5,45 | 6,85 | |
Current in cooling (1p 230V / 3p 400) | A | 7,05 | 9,50 | 11,50 | 15,60 | 19,50 | 3,90 | 5,20 | 6,50 | |
Current in cooling (1p 240V / 3p 415) | A | 6,75 | 9,10 | 11,10 | 15,00 | 18,70 | 3,75 | 5,00 | 6,25 | |
Current in heating (1p 220V / 3p 380) | A | 6,25 | 8,05 | 9,25 | 13,10 | 15,60 | 3,15 | 4,40 | 5,25 | |
Current in heating (1p 230V / 3p 400) | A | 5,95 | 7,70 | 8,85 | 12,60 | 15,00 | 3,00 | 4,15 | 4,95 | |
Current in heating (1p 240V / 3p 415) | A | 5,70 | 7,35 | 8,50 | 12,00 | 14,30 | 2,90 | 4,00 | 4,80 | |
Outdoor air flow (Cool) | m³/min | 40 | 50 | 76 | 86 | 89 | 76 | 86 | 89 | |
Outdoor air flow (Heat) | m³/min | 45 | 45 | 70 | 78 | 83 | 70 | 78 | 83 | |
Outdoor sound pressure (Cool -Hi) | dB(A) | 46 | 49 | 52 | 55 | 56 | 52 | 55 | 56 | |
Outdoor sound pressure (Heat -Hi) | dB(A) | 48 | 49 | 52 | 55 | 56 | 52 | 55 | 56 | |
Outdoor sound power (Cool -Hi) | dB(A) | 65 | 69 | 70 | 73 | 74 | 70 | 73 | 74 | |
Outdoor sound power (Heat -Hi) | dB(A) | 68 | 69 | 70 | 73 | 74 | 70 | 73 | 74 | |
Outdoor dimension (Height) | mm | 695 | 695 | 996 | 996 | 996 | 996 | 996 | 996 | |
Outdoor dimension (Width) | mm | 875 | 875 | 980 | 980 | 980 | 980 | 980 | 980 | |
Outdoor dimension (Depth) | mm | 320 | 320 | 370 | 370 | 370 | 370 | 370 | 370 | |
Pipe length range | m | 3 ~ 40 | 3 ~ 40 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | |
Elevation difference (in/out) (5) | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.