Etherea Inverter+ Pure White Matt • R32
2.1 kW
Kit KIT-Z20-VKE
EER (Min) (1) W/W 3,13
EER (Max) (1) W/W 4,32
Annual energy consumption cooling (3) kWh/a 98,00
Heating capacity at -7°C kW 2,38
COP (Min) (1) W/W 3,89
COP (Max) (1) W/W 4,04
Annual energy consumption heating (3) kWh/a 626
Indoor power source V 230
Indoor recommended fuse A 16
Indoor air flow (Cool) m³/min 9,9
Indoor air flow (Heat) m³/min 10,7
Moisture removal volume L/h 1,3
Indoor sound pressure (Cool -Hi) (4) dB(A) 37
Indoor sound pressure (Cool -Hi) (4) dB(A) 37
Indoor sound pressure (Cool -Lo) (4) dB(A) 24
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 19
Indoor sound pressure (Heat -Hi) (4) dB(A) 38
Indoor sound pressure (Heat -Lo) (4) dB(A) 25
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 19
nanoe X Generator Mark 1
Outdoor unit CU-Z20VKE
Outdoor air flow (Cool) m³/min 26,9
Outdoor air flow (Heat) m³/min 24,1
Outdoor sound pressure (Cool -Hi) (4) dB(A) 45
Outdoor sound pressure (Cool -Hi) (4) dB(A) 45
Outdoor sound pressure (Heat -Hi) (4) dB(A) 46
Outdoor dimension (Height) (5) mm 542
Outdoor dimension (Width) (5) mm 780
Outdoor dimension (Depth) (5) mm 289
Pipe length range m 3 ~ 15
Elevation difference (in/out) (6) m 15

(1) EER and COP calculation is based in accordance to EN14511. 
(2) Energy Label Scale from A+++ to D. 
(3) The annual energy consumption is calculated in accordance to EU/626/2011. 
(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed. 
(5) Add 70 mm for piping port. 
(6) When installing the outdoor unit at a higher position than the indoor unit.