PACi Elite adaptive ducted unit - PF3 - R32

Newly designed adaptive ducted unit - PF3 for R32 PACi

2 installation possibilities (horizontal / vertical) with high external static pressure 150Pa allows flexible installation.

Looduslik tasakaal siseruumides

New adaptive ducted PF3

The next generation of commercial air conditioners is here

Specifications

See all
PACi Elite adaptive ducted unit - PF3 - R32
12.5 kW
Kit KIT-125PF3ZH28
Remote controller CZ-RTC6
EER (Min) (1) W/W 5,00
EER (Max) (1) W/W 3,00
SEER/ηsc (2) % 281,7
Annual energy consumption cooling (3) kWh/a
COP (Min) (1) W/W 5,16
COP (Max) (1) W/W 3,06
SCOP/ηsc (2) % 170,0
Annual energy consumption heating (3) kWh/a
External static pressure (Nominal) (4) Pa 50
External static pressure (Min) (4) Pa 10
External static pressure (Max) (4) Pa 150
Moisture removal volume L/h 4,1
Indoor air flow (Hi) m³/min 34,0
Indoor air flow (Med) m³/min 29,0
Indoor air flow (Lo) m³/min 23,0
Indoor sound pressure (Hi) (5) dB(A) 35
Indoor sound pressure (Med) (5) dB(A) 31
Indoor sound pressure (Lo) (5) dB(A) 27
Indoor sound power (Hi) dB(A) 58
Indoor sound power (Med) dB(A) 54
Indoor sound power (Lo) dB(A) 50
nanoe X Generator Mark 2
Outdoor unit U-125PZH2E8
Outdoor power source V 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 5,20
Current in cooling (1p 230V / 3p 400) A 4,95
Current in cooling (1p 240V / 3p 415) A 4,80
Current in heating (1p 220V / 3p 380) A 6,05
Current in heating (1p 230V / 3p 400) A 5,75
Current in heating (1p 240V / 3p 415) A 5,55
Outdoor air flow (Cool) m³/min 125
Outdoor air flow (Heat) m³/min 112
Outdoor sound pressure (Cool -Hi) dB(A) 53
Outdoor sound pressure (Heat -Hi) dB(A) 53
Outdoor sound power (Cool -Hi) dB(A) 70
Outdoor sound power (Heat -Hi) dB(A) 70
Outdoor dimension (Height) mm 1416
Outdoor dimension (Width) mm 940
Outdoor dimension (Depth) mm 340
Pipe length range m 5 ~ 85
Elevation difference (in/out) (6) m 30
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12kW, the ηsc / ηsh values is calculated based on EN 14825.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Medium External static pressure setting from factory.
(5) The sound pressure of the units shows the value measured of the position 1,5m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(6) When installing the outdoor unit at a higher position than the indoor unit.
(7) For models 100~140PZH2E5(8), it is possible to operate the lowest -20°C in the computer rooms with the piping length of 30m or less.
* Recommended fuse for the indoor 3A.
** Above values are in the case of standard installation(horizontal installation in the celling, rear side air intake) and nanoe™ X OFF.