Panasonic HZ25XKE Flagship Inverter+ - R32

Tidligere egenskab Næste kapacitet

Flagship: en meget kærkommen tilføjelse til dit hjem

Den nye, smarte Flagship har nu nanoe™ X-teknologi, der drager fordel af hydroxylradikaler. Med avancerede styringsmuligheder, ydeevne på topniveau, et stilfuldt design og intelligente funktioner er Flagship designet til at gøre dit hjem komfortabelt, renere og et rart sted at være, selv under ekstreme forhold.

Klimaanlæg, der kan forbindes til fremtiden

Specifikationer

Se alle
Panasonic HZ25XKE Flagship Inverter+ - R32
7.5 kW
Maximum capacity kW 7,50 kW
Reference CS-HZ25XKE + CU-HZ25XKE
Heating capacity (Nominal) kW 3,20
Heating capacity (Min) kW 0,85
Heating capacity (Max) kW 7,50
COP (1) W/W 5,61 
Heating capacity at -7°C (2) kW 5,00
COP at -7°C (1) W/W 2,58
Heating capacity at -15°C (2) kW 4,78
COP at -15°C (1) W/W 2,54
Heating capacity at -20°C (2) kW 4,20
COP at -20°C (1) W/W 2,40
Heating capacity at -25°C (2) kW 3,60
COP at -25°C (1) W/W 2,22
SCOP (3) 5,30 A+++
Pdesign at -10°C kW 3,00
Input power heating (Nominal) kW 0,57
Input power heating (Min) kW 0,17
Input power heating (Max) kW 2,16
Annual energy consumption heating (4) kWh/a 792
Cooling capacity (Nominal) kW 2,50
Cooling capacity (Min) kW 0,85
Cooling capacity (Max) kW 3,00
SEER (3) 8,70 A+++
Pdesign (cooling) kW 2,50
Input power cooling (Nominal) kW 0,46
Input power cooling (Min) kW 0,17
Input power cooling (Max) kW 0,67
Annual energy consumption cooling (4) kWh/a 101
Indoor unit CS-HZ25XKE
Indoor power source V 230
Indoor air flow (Heat) m³/min 15,7
Indoor air flow (Cool) m³/min 14,1
Moisture removal volume L/h 1,5
Indoor sound pressure (Heat -Hi) (5) dB(A) 45
Indoor sound pressure (Heat -Lo) (5) dB(A) 24
Indoor sound pressure (Heat -Q-Lo) (5) dB(A) 18
Indoor sound pressure (Cool -Hi) (5) dB(A) 44
Indoor sound pressure (Cool -Lo) (5) dB(A) 25
Indoor sound pressure (Cool -Q-Lo) (5) dB(A) 20
Indoor dimension (Height) mm 295
Indoor dimension (Width) mm 870
Indoor dimension (Depth) mm 229
Indoor net weight kg 11
nanoe X Generator Mark 2
Outdoor unit CU-HZ25XKE
Outdoor air flow (Heat) m³/min 32,7
Outdoor air flow (Cool) m³/min 32,7
Outdoor sound pressure (Heat -Hi) (5) dB(A) 47
Outdoor sound pressure (Heat -Lo) (5) dB(A) 44
Outdoor sound pressure (Cool -Hi) (5) dB(A) 46
Outdoor sound pressure (Cool -Lo) (5) dB(A) 43
Outdoor dimension (Height) (6) mm 622
Outdoor dimension (Width) (6) mm 824
Outdoor dimension (Depth) (6) mm 299
Outdoor net weight kg 34
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52)
Pipe length range m 3 ~ 20
Elevation difference (in/out) (7) m 10
Pipe length for additional gas m 7,5
Additional gas amount g/m 10
Refrigerant (R32) / CO2 Eq. kg / T 1,06 / 0,716
Operating range (Heat - Min) °C -25
Operating range (Heat - Max) °C +24
Operating range (Cool - Min) °C +16
Operating range (Cool - Max) °C +43

1) COP beregnes i henhold til EN14511.
2) Varmepumpens kapacitet er testet ved maksimal effekt og afrimning.
3) SCOP og SEER-værdierne er Panasonic-fabrikkernes officielle resultat, energimærkningsskala fra A+++ til D.
4) Det årlige energiforbrug beregnes i henhold til EU/626/2011.
5) Indendørsenhedens lydtryk viser værdien målt i en position af 1 meter foran hoveddelen og 0,8 meter under enheden. For udendørsenheden 1 meter foran og 1 meter bag ved hoveddelen. Lydtrykket er målt i overensstemmelse med JIS C 9612. S-Lav: Støjsvag tilstand. Lav: Laveste blæserhastighed.
6) Tillæg 70 mm til rørindføring.
7) Ved installation af udendørs enheden i en højere position end indendørs enheden.

Supplerende produkter