PACi Standard High Static Pressure Hide Away • R410A
The ducted systems are the ideal solution for flexible, concealed air conditioning and the optional 200 mm spigots ensure simple, hassle-free connection to spiral ductwork.
- High ESP (external static pressure) up to 150 Pa
- Automatic learning function for the required static pressure on site during commissioning (a standard wired remote controller is required)
- DC FAN for better efficiency and control
- Built in drain pump
- Datanavi simple support tool App with remote controller (CZ-RTC5B)
- Twin split options
- Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be controlled by the remote control of the Panasonic indoor unit
Široká škála aplikací pro komerční,
kancelářské nebo rezidenční budovy
Komerční jednotky vzduch–vzduch
PACi Standard nebo Elite
Dvě řešení pro komerční, kancelářské nebo rezidenční budovy.
Technické údaje
PACi Standard High Static Pressure Hide Away • R410A | |||
---|---|---|---|
12.5 kW | |||
EER (Nominal) (1) | W/W | 3,05 (4,22 - 2,70) B | |
COP (Nominal) (1) | W/W | 3,82 (4,66 - 3,41) A | |
EER (Nominal) (1) | W/W | 3,05 (4,22 - 2,70) B | |
Heating capacity at -7°C (2) | kW | 11,00 | |
Heating capacity at -15°C (2) | kW | — | |
COP (Nominal) (1) | W/W | 3,82 (4,66 - 3,41) A | |
External static pressure (Nominal) (5) | Pa | 100 | |
External static pressure (Min) (5) | Pa | 10 | |
External static pressure (Max) (5) | Pa | 150 | |
Indoor sound pressure (Hi) (6) | dB(A) | 39 | |
Indoor sound pressure (Med) (6) | dB(A) | 35 | |
Indoor sound pressure (Lo) (6) | dB(A) | 32 | |
Elevation difference (in/out) (7) | m | 30 | |
Refrigerant (R410A) / CO2 Eq. | kg / T | 3,20 / 6,6816 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) Heating capacity is calculated including defrost factor correction.
(5) Medium external static pressure setting from factory.
(6) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(7) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.