PACi Elite Ceiling • R32

Ceiling mounted units provides large and wide air distribution which is good for big rooms. The height and depth of all capacities are the same for unified appearance in mixed installations.

Specifications

See all
PACi Elite Ceiling • R32 SINGLE PHASE THREE PHASE
3.6 kW 5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW
Kit KIT-36PT2ZH5 KIT-50PT2ZH5 KIT-60PT2ZH5 KIT-71PT2ZH5 KIT-100PT2ZH5 KIT-125PT2ZH5 KIT-140PT2ZH5 KIT-71PT2ZH8 KIT-100PT2ZH8 KIT-125PT2ZH8 KIT-140PT2ZH8
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Annual energy consumption cooling (3) kWh/a 175 250 292 371 500 375 507
Annual energy consumption cooling (3) kWh/a 175 250 292 371 500 375 507
Annual energy consumption heating (3) kWh/a 1050 1370 1787 1583 2435 1583 2435
Indoor air flow (Hi) m³/min 14,0 15,0 20,0 21,0 30,0 34,0 35,0 21,0 30,0 34,0 35,0
Indoor air flow (Med) m³/min 12,0 12,5 17,0 18,0 25,0 28,0 29,0 18,0 25,0 28,0 29,0
Indoor air flow (Lo) m³/min 10,5 10,5 14,5 15,5 23,0 24,0 25,0 15,5 23,0 24,0 25,0
Indoor sound pressure (Med) (4) dB(A) 32 33 34 35 37 40 41 35 37 40 41
Indoor sound pressure (Lo) (4) dB(A) 29 29 30 31 35 36 37 31 35 36 37
Outdoor power source V 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 220 - 230 - 240 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415 380 - 400 - 415
Current in cooling (1p 220V / 3p 380) A 3,35 5,60 7,15 8,80 11,40 16,80 21,00 2,95 3,85 5,65 7,10
Current in cooling (1p 230V / 3p 400) A 3,25 5,35 6,85 8,45 10,90 -10,50 16,00 20,10 2,85 3,65 5,40 6,75
Current in cooling (1p 240V / 3p 415) A 3,10 5,10 6,55 8,10  12,00 15,40 19,30 2,75 3,55 5,20 6,50
Current in heating (1p 220V / 3p 380) A 3,65 6,10 7,75 8,90 11,50 16,20 20,30 3,00 4,05 5,50 6,85
Current in heating (1p 230V / 3p 400) A 3,50 5,85 7,40 8,50 11,00 15,50 19,40 2,90 3,85 5,20 6,50
Current in heating (1p 240V / 3p 415) A 3,35 5,60 7,10 8,20 118,00 14,90 18,60 2,80 3,75 5,05 6,30
Outdoor air flow (Cool) m³/min 40 40 40 61 108 125 129 61 118 125 129
Outdoor air flow (Heat) m³/min 40 45 45 60 52 122 116 60 108 112 116
Outdoor sound pressure (Cool -Hi) dB(A) 43 45 46 48 52 53 54 48 52 53 54
Outdoor sound pressure (Heat -Hi) dB(A) 44 48 49 50 69 53 54 50 52 53 54
Outdoor sound power (Cool -Hi) dB(A) 62 64 65 65 69 70 71 65 69 70 71
Outdoor sound power (Heat -Hi) dB(A) 64 68 69 67 1416 70 71 67 69 70 71
Outdoor dimension (Height) mm 695 695 695 996 940 1416 1416 996 1416 1416 1416
Outdoor dimension (Width) mm 875 875 875 940 340 940 940 940 940 940 940
Outdoor dimension (Depth) mm 320 320 320 340 99 340 340 340 340 340 340
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 50 30 5 ~ 85 5 ~ 85 5 ~ 50 5 ~ 85 5 ~ 85 5 ~ 85
Elevation difference (in/out) (5) m 30 30 30 30 30 30 30 30 30 30 30

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
(6) For models 100 ~ 140PZH2E5(8), it is possible to operate the lowest -20 °C in the computer rooms with the piping length of 30 m or less.
* Recommended fuse for the indoor 3 A.

Complementary products

What's happening