Plafonnier PACi Standard • R32 | Monophasé | Triphasé | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
6.0 kW | 7.1 kW | 10.0 kW | 12.5 kW | 14.0 kW | 10.0 kW | 12.5 kW | 14.0 kW | |||
Kit | KIT-60PT2Z5 | KIT-71PT2Z5 | KIT-100PT2Z5 | KIT-125PT2Z5 | KIT-140PT2Z5 | KIT-100PT2Z8 | KIT-125PT2Z8 | KIT-140PT2Z8 | ||
Remote controller | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | CZ-RTC5B | ||
Cooling capacity (Nominal) | kW | 6,0 | 7,1 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
Cooling capacity (Min) | kW | 2,0 | 2,0 | 3,0 | 3,2 | 3,3 | 3,0 | 3,2 | 3,3 | |
Cooling capacity (Max) | kW | 7,1 | 7,7 | 11,5 | 13,5 | 15,0 | 11,5 | 13,5 | 15,0 | |
EER (Nominal) (1) | W/W | 4,00 | 3,55 | 3,64 | 3,32 | 2,98 | 3,64 | 3,32 | 2,98 | |
EER (Min) (1) | W/W | 5,36 | 5,33 | 5,32 | 5,36 | 5,33 | 5,32 | |||
EER (Max) (1) | W/W | 2,80 | 2,77 | 2,73 | 2,80 | 2,77 | 2,73 | |||
SEER (2) | 6,8 A++ | 6,5 A++ | 6,5 A++ | 5,8 | 5,5 | 6,5 A++ | 5,8 | 5,5 | ||
Pdesign (cooling) | kW | 6,0 | 7,1 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
Input power cooling (Nominal) | kW | 1,50 | 2,00 | 2,75 | 3,76 | 4,70 | 2,75 | 3,76 | 4,70 | |
Input power cooling (Min) | kW | 0,56 | 0,60 | 0,62 | 0,56 | 0,60 | 0,62 | |||
Input power cooling (Max) | kW | 4,10 | 4,88 | 5,50 | 4,10 | 4,88 | 5,50 | |||
Annual energy consumption cooling (3) | kWh/a | 309 | 382 | 535 | 1300 | 1530 | 538 | 1304 | 1534 | |
Heating capacity (Nominal) | kW | 6,0 | 7,1 | 10,0 | 12,5 | 14,0 | 10,0 | 12,5 | 14,0 | |
Heating capacity (Min) | kW | 1,8 | 1,8 | 3,0 | 3,3 | 3,4 | 3,0 | 3,3 | 3,4 | |
Heating capacity (Max) | kW | 7,0 | 8,1 | 14,0 | 15,0 | 16,0 | 14,0 | 15,0 | 16,0 | |
COP (Nominal) (1) | W/W | 4,80 | 4,41 | 4,24 | 3,89 | 3,70 | 4,24 | 3,89 | 3,70 | |
COP (Min) (1) | W/W | 5,36 | 4,52 | 5,48 | 5,36 | 4,52 | 5,48 | |||
COP (Max) (1) | W/W | 3,50 | 3,41 | 3,08 | 3,50 | 3,41 | 3,08 | |||
SCOP (2) | 4,6 A++ | 4,3 A+ | 4,2 A+ | 3,8 | 3,7 | 4,2 A+ | 3,8 | 3,7 | ||
Pdesign at -10°C | kW | 6,0 | 6,0 | 10,0 | 12,5 | 13,6 | 10,0 | 12,5 | 13,6 | |
Input power heating (Nominal) | kW | 1,25 | 1,62 | 2,36 | 3,21 | 3,78 | 2,36 | 3,21 | 3,78 | |
Input power heating (Min) | kW | 0,56 | 0,73 | 0,62 | 0,56 | 0,73 | 0,62 | |||
Input power heating (Max) | kW | 4,00 | 4,40 | 5,20 | 4,00 | 4,40 | 5,20 | |||
Annual energy consumption heating (3) | kWh/a | 1826 | 1953 | 3324 | 4669 | 5153 | 3324 | 4669 | 5153 | |
Indoor unit | S-60PT2E5B | S-71PT2E5B | S-100PT2E5B | S-125PT2E5B | S-140PT2E5B | S-100PT2E5B | S-125PT2E5B | S-140PT2E5B | ||
Indoor air flow (Hi) | m³/min | 20,0 | 21,0 | 30,0 | 34,0 | 35,0 | 30,0 | 34,0 | 35,0 | |
Indoor air flow (Med) | m³/min | 17,0 | 18,0 | 25,0 | 28,0 | 29,0 | 25,0 | 28,0 | 29,0 | |
Indoor air flow (Lo) | m³/min | 14,5 | 15,5 | 23,0 | 24,0 | 25,0 | 23,0 | 24,0 | 25,0 | |
Moisture removal volume | L/h | 3,4 | 4,2 | 6,0 | 7,9 | 9,0 | 6,0 | 7,9 | 9,0 | |
Indoor sound pressure (Med) (4) | dB(A) | 34 | 35 | 37 | 40 | 41 | 37 | 40 | 41 | |
Indoor sound pressure (Lo) (4) | dB(A) | 30 | 31 | 35 | 36 | 37 | 35 | 36 | 37 | |
Indoor sound power (Hi) | dB(A) | 56 | 57 | 60 | 64 | 65 | 60 | 64 | 65 | |
Indoor sound power (Med) | dB(A) | 52 | 53 | 55 | 58 | 59 | 55 | 58 | 59 | |
Indoor sound power (Lo) | dB(A) | 48 | 49 | 53 | 54 | 55 | 53 | 54 | 55 | |
Indoor dimension (Height) | mm | 235 | 235 | 235 | 235 | 235 | 235 | 235 | 235 | |
Indoor dimension (Width) | mm | 1275 | 1275 | 1590 | 1590 | 1590 | 1590 | 1590 | 1590 | |
Indoor dimension (Depth) | mm | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | |
Indoor net weight | kg | 33 | 33 | 40 | 40 | 40 | 40 | 40 | 40 | |
Outdoor unit | U-60PZ2E5 | U-71PZ2E5 | U-100PZ2E5 | U-125PZ2E5 | U-140PZ2E5 | U-100PZ2E8 | U-125PZ2E8 | U-140PZ2E8 | ||
Outdoor power source | V | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 220 - 230 - 240 | 380 - 400 - 415 | 380 - 400 - 415 | 380 - 400 - 415 | |
Current in cooling (1p 220V / 3p 380) | A | 7,30 | 9,70 | 12,80 | 17,60 | 22,10 | 4,37 | 5,90 | 7,40 | |
Current in cooling (1p 230V / 3p 400) | A | 7,00 | 9,30 | 12,20 | 16,90 | 21,20 | 4,15 | 5,60 | 7,05 | |
Current in cooling (1p 240V / 3p 415) | A | 6,70 | 8,90 | 11,70 | 16,20 | 20,30 | 4,00 | 5,40 | 6,80 | |
Current in heating (1p 220V / 3p 380) | A | 6,05 | 7,85 | 10,90 | 15,00 | 17,70 | 3,72 | 5,00 | 5,90 | |
Current in heating (1p 230V / 3p 400) | A | 5,80 | 7,50 | 10,40 | 14,30 | 16,90 | 3,55 | 4,75 | 5,60 | |
Current in heating (1p 240V / 3p 415) | A | 5,55 | 7,20 | 10,00 | 13,70 | 16,20 | 3,40 | 4,60 | 5,40 | |
Outdoor air flow (Cool) | m³/min | 40 | 50 | 76 | 86 | 89 | 76 | 86 | 89 | |
Outdoor air flow (Heat) | m³/min | 45 | 45 | 70 | 78 | 83 | 70 | 78 | 83 | |
Outdoor sound pressure (Cool -Hi) | dB(A) | 46 | 49 | 52 | 55 | 56 | 52 | 55 | 56 | |
Outdoor sound pressure (Heat -Hi) | dB(A) | 48 | 49 | 52 | 55 | 56 | 52 | 55 | 56 | |
Outdoor sound power (Cool -Hi) | dB(A) | 65 | 69 | 70 | 73 | 74 | 70 | 73 | 74 | |
Outdoor sound power (Heat -Hi) | dB(A) | 68 | 69 | 70 | 73 | 74 | 70 | 73 | 74 | |
Outdoor dimension (Height) | mm | 695 | 695 | 996 | 996 | 996 | 996 | 996 | 996 | |
Outdoor dimension (Width) | mm | 875 | 875 | 980 | 980 | 980 | 980 | 980 | 980 | |
Outdoor dimension (Depth) | mm | 320 | 320 | 370 | 370 | 370 | 370 | 370 | 370 | |
Outdoor net weight | kg | 44 | 44 | 90 | 94 | 94 | 90 | 94 | 94 | |
Pipe diameter (Liquid) | Inch (mm) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | 3/8 (9,52) | |
Pipe diameter (Gas) | Inch (mm) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | 5/8 (15,88) | |
Pipe length range | m | 3 ~ 40 | 3 ~ 40 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | 5 ~ 50 | |
Elevation difference (in/out) (5) | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
Pipe length for additional gas | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
Additional gas amount | g/m | 35 | 35 | 45 | 45 | 45 | 45 | 45 | 45 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,45 / 0,979 | 1,45 / 0,979 | 2,60 / 1,755 | 2,98 / 2,0115 | 2,98 / 2,0115 | 2,60 / 1,755 | 2,98 / 2,0115 | 2,98 / 2,0115 | |
Operating range (Cool - Min) | °C | -10 | -10 | -10 | -10 | -10 | -10 | -10 | -10 | |
Operating range (Cool - Max) | °C | 43 | 43 | 43 | 43 | 43 | 43 | 43 | 43 | |
Operating range (Heat - Min) | °C | -15 | -15 | -15 | -15 | -15 | -15 | -15 | -15 | |
Operating range (Heat - Max) | °C | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1 m in front of the main body and 1 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.