Modellen
Small and powerful, ideal for offices and restaurants. Standard units only for Twin, Triple and Double-twin combinations.
Specificaties
PACi ELITE // 4-WEG CASSETTE // 60x60 // R32 | Einphasig | |||
---|---|---|---|---|
3.6 kW | 5.0 kW | |||
Kit | KIT-36PY2ZH5 | KIT-50PY2ZH5 | ||
Remote controller | CZ-RTC5B | CZ-RTC5B | ||
Cooling capacity (Nominal) | kW | 3,6 | 5,0 | |
Cooling capacity (Min) | kW | 1,5 | 1,5 | |
Cooling capacity (Max) | kW | 4,0 | 5,6 | |
EER (Nominal) (1) | W/W | 4,68 | 3,68 | |
SEER (2) | 6,6 A++ | 6,4 A++ | ||
Pdesign (cooling) | kW | 3,6 | 5,0 | |
Input power cooling (Nominal) | kW | 0,77 | 1,36 | |
Annual energy consumption cooling (3) | kWh/a | 191 | 273 | |
Heating capacity (Nominal) | kW | 4,0 | 5,6 | |
Heating capacity (Min) | kW | 1,5 | 1,5 | |
Heating capacity (Max) | kW | 5,0 | 6,5 | |
COP (Nominal) (1) | W/W | 4,26 | 3,46 | |
SCOP (2) | 4,6 A++ | 4,3 A+ | ||
Pdesign at -10°C | kW | 3,6 | 4,5 | |
Input power heating (Nominal) | kW | 0,94 | 1,62 | |
Annual energy consumption heating (3) | kWh/a | 1096 | 1465 | |
Indoor unit | S-36PY2E5B | S-50PY2E5B | ||
Indoor air flow (Hi) | m³/min | 9,7 | 11,1 | |
Indoor air flow (Med) | m³/min | 8,0 | 9,8 | |
Indoor air flow (Lo) | m³/min | 6,0 | 8,5 | |
Moisture removal volume | L/h | 1,5 | 2,4 | |
Indoor sound pressure (Med) (4) | dB(A) | 32 | 37 | |
Indoor sound pressure (Lo) (4) | dB(A) | 26 | 33 | |
Indoor sound power (Hi) | dB(A) | 51 | 55 | |
Indoor sound power (Med) | dB(A) | 47 | 52 | |
Indoor sound power (Lo) | dB(A) | 41 | 48 | |
Indoor dimension (Height) | mm | 288 | 288 | |
Indoor dimension (Width) | mm | 583 | 583 | |
Indoor dimension (Depth) | mm | 583 | 583 | |
Panel dimension (Height) | mm | 31 | 31 | |
Panel dimension (Depth) | mm | 700 | 700 | |
Indoor net weight | kg | 18 | 18 | |
Panel net weight | kg | 2,4 | 2,4 | |
Outdoor unit | U-36PZH2E5 | U-50PZH2E5 | ||
Outdoor power source | V | 220 - 230 - 240 | 220 - 230 - 240 | |
Current in cooling (1p 220V / 3p 380) | A | 3,65 | 6,35 | |
Current in cooling (1p 230V / 3p 400) | A | 3,50 | 6,10 | |
Current in cooling (1p 240V / 3p 415) | A | 3,35 | 5,85 | |
Current in heating (1p 220V / 3p 380) | A | 4,50 | 7,70 | |
Current in heating (1p 230V / 3p 400) | A | 4,30 | 8,40 | |
Current in heating (1p 240V / 3p 415) | A | 4,15 | 8,10 | |
Outdoor air flow (Cool) | m³/min | 40 | 40 | |
Outdoor air flow (Heat) | m³/min | 40 | 45 | |
Outdoor sound pressure (Cool -Hi) | dB(A) | 43 | 45 | |
Outdoor sound pressure (Heat -Hi) | dB(A) | 44 | 48 | |
Outdoor sound power (Cool -Hi) | dB(A) | 62 | 64 | |
Outdoor sound power (Heat -Hi) | dB(A) | 64 | 68 | |
Outdoor dimension (Height) | mm | 695 | 695 | |
Outdoor dimension (Width) | mm | 875 | 875 | |
Outdoor dimension (Depth) | mm | 320 | 320 | |
Outdoor net weight | kg | 43 | 43 | |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | 1/4 (6,35) | |
Pipe diameter (Gas) | Inch (mm) | 1/2 (12,70) | 1/2 (12,70) | |
Pipe length range | m | 3 ~ 40 | 3 ~ 40 | |
Elevation difference (in/out) (5) | m | 30 | 30 | |
Pipe length for additional gas | m | 30 | 30 | |
Additional gas amount | g/m | 20 | 20 | |
Refrigerant (R32) / CO2 Eq. | kg / T | 1,15 / 0,776 | 1,15 / 0,776 | |
Operating range (Cool - Min) | °C | -15 | -15 | |
Operating range (Cool - Max) | °C | 46 | 46 | |
Operating range (Heat - Min) | °C | -20 | -20 | |
Operating range (Heat - Max) | °C | 24 | 24 |
(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the SEER and SCOP is calculated based on values of EU/2281/2016.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
(5) When installing the outdoor unit at a higher position than the indoor unit.
* Recommended fuse for the indoor 3 A.