PACi NX Series Standard 4 way 60x60 cassette Inverter+ - R32

Vorige capaciteit Volgende capaciteit

4-weg 60x60 cassette - PY3

Van 2,5 tot 6,0 kW (4 capaciteiten beschikbaar)
Afmetingen van chassis (H x B x D): 243 x 575 x 575 mm
Ingebouwde afzuigpomp

Specificaties

Alles zien
PACi NX Series Standard 4 way 60x60 cassette Inverter+ - R32
6.0 kW
Kit KIT-60PY3Z5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 6,0
Cooling capacity (Min) kW 2,0
Cooling capacity (Max) kW 7,0
EER (Nominal) (1) W/W 3,39
EER (Min) (1) W/W 2,77
EER (Max) (1) W/W 6,90
SEER (2) 6,8 A++
Pdesign (cooling) kW 6,0
Input power cooling (Nominal) kW 1,77
Annual energy consumption cooling (3) kWh/a 3,05
Input power cooling (Min) kW 0,29
Input power cooling (Max) kW 2,53
Annual energy consumption cooling (3) kWh/a 3,05
Heating capacity (Nominal) kW 6,0
Heating capacity (Min) kW 1,8
Heating capacity (Max) kW 7,0
COP (Nominal) (1) W/W 3,61
COP (Min) (1) W/W 2,86
COP (Max) (1) W/W 7,60
SCOP (2) 4,2 A+
Pdesign at -10°C kW 4,6
Input power heating (Nominal) kW 1,66
Input power heating (Min) kW 0,24
Input power heating (Max) kW 2,45
Annual energy consumption heating (3) kWh/a 1.500
Indoor unit S-60PY3E
Indoor air flow (Hi) m³/min 14,0
Indoor air flow (Med) m³/min 10,5
Indoor air flow (Lo) m³/min 8,0
Moisture removal volume L/h 2,8
Indoor sound pressure (Med) (4) dB(A) 37
Indoor sound pressure (Lo) (4) dB(A) 31
Indoor sound power (Hi) dB(A) 58
Indoor sound power (Med) dB(A) 52
Indoor sound power (Lo) dB(A) 46
Indoor dimension (Height) mm 243
Indoor dimension (Width) mm 575
Indoor dimension (Depth) mm 575
Panel dimension (Height) mm 30
Panel dimension (Depth) mm 625
Indoor net weight kg 15
Panel net weight kg 2,8
nanoe X Generator Mark 2
Outdoor unit U-60PZ3E5A
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 8,20
Current in cooling (1p 230V / 3p 400) A 7,85
Current in cooling (1p 240V / 3p 415) A 7,55
Current in heating (1p 220V / 3p 380) A 7,70
Current in heating (1p 230V / 3p 400) A 7,35
Current in heating (1p 240V / 3p 415) A 7,05
Outdoor air flow (Cool) m³/min 42,6
Outdoor air flow (Heat) m³/min 41,5
Outdoor sound pressure (Cool -Hi) dB(A) 47
Outdoor sound pressure (Heat -Hi) dB(A) 48
Outdoor sound power (Cool -Hi) dB(A) 64
Outdoor sound power (Heat -Hi) dB(A) 65
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 46
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) (5)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) (6)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (5) m 15 / 30
Pipe length for additional gas m 30
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,15 / 0,78
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24
Kit KIT-60PY3Z5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 6,0
Cooling capacity (Min) kW 2,0
Cooling capacity (Max) kW 7,0
EER (Nominal) (1) W/W 3,39
EER (Min) (1) W/W 2,77
EER (Max) (1) W/W 6,90
SEER (2) 6,8 A++
Pdesign (cooling) kW 6,0
Input power cooling (Nominal) kW 1,77
Input power cooling (Min) kW 0,29
Input power cooling (Max) kW 2,53
Annual energy consumption cooling (3) kWh/a 3,05
Heating capacity (Nominal) kW 6,0
Heating capacity (Min) kW 1,8
Heating capacity (Max) kW 7,0
COP (Nominal) (1) W/W 3,61
COP (Min) (1) W/W 2,86
COP (Max) (1) W/W 7,60
SCOP (2) 4,2 A+
Pdesign at -10°C kW 4,6
Input power heating (Nominal) kW 1,66
Input power heating (Min) kW 0,24
Input power heating (Max) kW 2,45
Annual energy consumption heating (3) kWh/a 1.500
Indoor unit S-60PY3E
Indoor air flow (Hi) m³/min 14,0
Indoor air flow (Med) m³/min 10,5
Indoor air flow (Lo) m³/min 8,0
Moisture removal volume L/h 2,8
Indoor sound pressure (Med) (4) dB(A) 37
Indoor sound pressure (Lo) (4) dB(A) 31
Indoor sound power (Hi) dB(A) 58
Indoor sound power (Med) dB(A) 52
Indoor sound power (Lo) dB(A) 46
Indoor dimension (Height) mm 243
Indoor dimension (Width) mm 575
Indoor dimension (Depth) mm 575
Panel dimension (Height) mm 30
Panel dimension (Depth) mm 625
Indoor net weight kg 15
Panel net weight kg 2,8
nanoe X Generator Mark 2
Outdoor unit U-60PZ3E5A
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 8,20
Current in cooling (1p 230V / 3p 400) A 7,85
Current in cooling (1p 240V / 3p 415) A 7,55
Current in heating (1p 220V / 3p 380) A 7,70
Current in heating (1p 230V / 3p 400) A 7,35
Current in heating (1p 240V / 3p 415) A 7,05
Outdoor air flow (Cool) m³/min 42,6
Outdoor air flow (Heat) m³/min 41,5
Outdoor sound pressure (Cool -Hi) dB(A) 47
Outdoor sound pressure (Heat -Hi) dB(A) 48
Outdoor sound power (Cool -Hi) dB(A) 64
Outdoor sound power (Heat -Hi) dB(A) 65
Outdoor dimension (Height) mm 695
Outdoor dimension (Width) mm 875
Outdoor dimension (Depth) mm 320
Outdoor net weight kg 46
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) (5)
Pipe diameter (Gas) Inch (mm) 1/2 (12,70) (6)
Pipe length range m 3 ~ 40
Elevation difference (in/out) (7) m 15 / 30 (8)
Pipe length for additional gas m 30
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,15 / 0,78
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

1) EER- en COP-berekening op basis van EN14511.
2) Voor modellen van 12kW en minder zijn de SEER en SCOP gebaseerd op de waardes van EU/626/2011. Voor modellen boven de 12kW is de ηsc / ηsh waarde gebaseerd op EN 14825.
3) Fabrieksinstellingen.
4) De geluidsdruk van de unit toont de waarde gemeten 1,5m onder de unit. De geluidsdruk is gemeten in overeenstemming met de Eurovent 6/C/006-97-specificatie.
5) Verbind de buisvoet (Ø6,35-Ø9,52) met de vloeistofleiding van de binnenunit. 
6) Verbind de buisvoet (Ø12,70-Ø15,88) met de gasleiding van de binnenunit. 
7) Indien de buitenunit hoger is geplaatst dan de binnenunit.
8) Binnenunit is lager geplaatst / buitenunit is hoger geplaatst.

* Aanbevolen zekering voor 3A binnen.
** De waardes zijn gemeten met nanoe™ X uitgeschakeld.
*** Beschikbaar in de herfst van 2021.
**** Voorlopige gegevens.

Wat er speelt