2 kW 5 kW 6 kW 2.5 kW 3.5 kW 4.2 kW 7.1 kW
Kit KIT-TZ20-WKE KIT-TZ50-WKE KIT-TZ60-WKE KIT-TZ25-WKE KIT-TZ35-WKE KIT-TZ42-WKE KIT-TZ71-WKE
Cooling capacity (Nominal) kW 2,00 5,00 6,00 2,50 3,50 4,20 7,10
Cooling capacity (Min) kW 0,75 0,98 0,98 0,85 0,85 0,85 0,98
Cooling capacity (Max) kW 2,40 5,60 6,60 3,00 3,90 4,60 8,20
EER (Nominal) (1) W/W 4,08 3,13 3,24 3,85 3,57 3,36 3,17
EER (Min) (1) W/W 4,17 3,92 3,92 4,05 3,62 3,62 2,33
EER (Max) (1) W/W 4,00 2,95 2,87 3,41 3,36 2,80 2,98
SEER (2) 7,00 A++ 6,90 A++ 6,80 A++ 7,00 A++ 6,80 A++ 6,40 A++ 6,20 A++
Pdesign (cooling) kW 2,00 5,00 6,00 2,50 3,50 4,20 7,10
Input power cooling (Nominal) kW 0,49 1,60 1,85 0,65 0,98 1,25 2,24
Input power cooling (Min) kW 0,18 0,25 0,25 0,21 0,24 0,24 0,42
Input power cooling (Max) kW 0,60 1,90 2,30 0,88 1,16 1,64 2,75
Annual energy consumption cooling (3) kWh/a 100,00 254,00 309,00 125,00 180,00 230,00 401,00
Heating capacity (Nominal) kW 2,70 5,80 7,00 3,30 4,00 5,00 8,60
Heating capacity (Min) kW 0,70 0,98 0,98 0,80 0,80 0,80 0,98
Heating capacity (Max) kW 3,60 7,50 8,20 4,10 5,10 6,80 9,90
Heating capacity at -7°C kW 2,14 4,62 4,90 2,70 3,30 3,90 6,13
COP (Nominal) (1) W/W 4,15 3,41 3,68 4,18 4,04 3,73 3,51
COP (Min) (1) W/W 4,24 4,67 4,67 4,21 4,10 4,10 2,45
COP (Max) (1) W/W 3,53 3,26 3,57 3,66 3,70 3,33 3,47
SCOP (2) 4,60 A++ 4,50 A+ 4,30 A+ 4,60 A++ 4,60 A++ 4,00 A+ 4,00 A+
Pdesign at -10°C kW 1,90 4,00 4,40 2,40 2,80 3,60 5,50
Input power heating (Nominal) kW 0,65 1,70 1,90 0,79 0,99 1,34 2,45
Input power heating (Min) kW 0,17 0,21 0,21 0,19 0,20 0,20 0,40
Input power heating (Max) kW 1,02 2,30 2,30 1,12 1,38 2,04 2,85
Annual energy consumption heating (3) kWh/a 578 1244 1433 730 852 1260 1925
Indoor unit CS-TZ20WKEW CS-TZ50WKEW CS-TZ60WKEW CS-TZ25WKEW CS-TZ35WKEW CS-TZ42WKEW CS-TZ71WKEW
Indoor power source V 230 230 230 230 230 230 230
Indoor recommended fuse A 16 16 20 16 16 16 20
Indoor connection indoor / outdoor mm² 4 x 1,5 4 x 2,5 4 x 2,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 2,5
Indoor air flow (Cool) m³/min 10,3 12,5 20,9 11,0 11,8 12,5 22,1
Indoor air flow (Heat) m³/min 10,8 13,2 21,9 11,5 12,3 13,2 22,9
Moisture removal volume L/h 1,3 2,8 3,3 1,5 2,0 2,4 4,1
Indoor sound pressure (Cool -Hi) (4) dB(A) 37 44 45 40 42 44 47
Indoor sound pressure (Cool -Lo) (4) dB(A) 25 37 37 26 30 31 38
Indoor sound pressure (Cool -Q-Lo) (4) dB(A) 20 33 34 20 20 29 35
Indoor sound pressure (Heat -Hi) (4) dB(A) 38 44 45 40 42 44 47
Indoor sound pressure (Heat -Lo) (4) dB(A) 26 37 37 27 33 35 38
Indoor sound pressure (Heat -Q-Lo) (4) dB(A) 22 33 34 22 22 28 35
Indoor dimension (Height) mm 290 290 302 290 290 290 302
Indoor dimension (Width) mm 779 779 1102 779 779 779 1102
Indoor dimension (Depth) mm 209 209 244 209 209 209 244
Indoor net weight kg 8 8 13 8 8 8 13
Outdoor unit CU-TZ20WKE CU-TZ50WKE CU-TZ60WKE CU-TZ25WKE CU-TZ35WKE CU-TZ42WKE CU-TZ71WKE
Outdoor air flow (Cool) m³/min 29,7 32,7 34,0 30,0 28,7 30,4 44,7
Outdoor air flow (Heat) m³/min 29,7 32,7 34,0 28,9 29,7 30,8 45,9
Outdoor sound pressure (Cool -Hi) (4) dB(A) 46 48 49 47 48 49 52
Outdoor sound pressure (Heat -Hi) (4) dB(A) 47 49 51 48 50 51 54
Outdoor dimension (Height) (5) mm 542 619 619 542 542 542 695
Outdoor dimension (Width) (5) mm 780 824 824 780 780 780 875
Outdoor dimension (Depth) (5) mm 289 299 299 289 289 289 320
Outdoor net weight kg 24 36 36 25 31 31 50
Pipe diameter (Liquid) Inch (mm) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35) 1/4 (6,35)
Pipe diameter (Gas) Inch (mm) 3/8 (9,52) 1/2 (12,7) 1/2 (12,7) 3/8 (9,52) 3/8 (9,52) 1/2 (12,7) 5/8 (15,88)
Pipe length range m 3 ~ 15 3 ~ 20 3 ~ 30 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 30
Elevation difference (in/out) (6) m 15 15 15 15 15 15 20
Pipe length for additional gas m 7,5 7,5 10 7,5 7,5 7,5 10
Additional gas amount g/m 10 15 15 10 10 10 25
Refrigerant (R32) / CO2 Eq. kg / T 0,54 / 0,365 1,14 / 0,770 1,22 / 0,824 0,67 / 0,452 0,77 / 0,520 0,79 / 0,533 1,32 / 0,891
Operating range (Cool - Min) °C -10 -10 -10 -10 -10 -10 -10
Operating range (Cool - Max) °C +43 +43 +43 +43 +43 +43 +43
Operating range (Heat - Min) °C -15 -15 -15 -15 -15 -15 -15
Operating range (Heat - Max) °C +24 +24 +24 +24 +24 +24 +24

(1) EER and COP calculation is based in accordance to EN14511.
(2) Energy Label Scale from A+++ to D.
(3) The annual energy consumption is calculated in accordance to EU/626/2011.
(4) The sound pressure of the indoor unit shows the value measured of a position 1 m in front of the main body and 0,8 m below the unit. For outdoor unit 1 m in front and 1 m in rear side of main body. The sound pressure is measured in accordance with JIS C 9612. Q-Lo: Quiet mode. Lo: The lowest set fan speed.
(5) Add 70 mm for piping port.
(6) When installing the outdoor unit at a higher position than the indoor unit.

Complementary products