Modeli
Kanalni sustavi idealno su rješenje za fleksibilne, skrivene klimatizacije, a opcijski priključci od 200 mm osiguravaju jednostavno spajanje na spiralne kanale bez problema.
Specifikacije
PACi skriveni visoki statički tlak • R410A | JEDNOFAZNO | TROFAZNO | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3.6 kW | 5.0 kW | 6.0 kW | 7.1 kW | 10.0 kW | 12.5 kW | 14.0 kW | 7.1 kW | 10.0 kW | 12.5 kW | 14.0 kW | |||||
EER (Nominal) (1) | W/W | 4,44 (5,17 - 4,00) A | 3,85 (5,17 - 3,50) A | 3,64 (5,97 - 3,02) A | 3,84 (4,72 - 3,02) A | 4,10 (3,93 - 3,38) A | 3,50 (3,93 - 3,04) A | 3,25 (3,93 - 2,58) A | 3,84 (5,00 - 3,02) A | 4,10 (3,93 - 3,38) A | 3,50 (3,93 - 3,04) A | 3,25 (3,93 - 2,58) A | |||
COP (Nominal) (1) | W/W | 4,55 (6,25 - 4,17) A | 4,03 (6,25 - 3,71) A | 4,00 (6,32 - 3,81) A | 3,85 (4,17 - 3,10) A | 4,31 (4,56 - 3,18) A | 4,02 (4,56 - 3,08) A | 3,60 (4,56 - 3,05) A | 3,85 (4,83 - 3,10) A | 4,31 (4,56 - 3,18) A | 4,02 (4,56 - 3,08) A | 3,60 (4,56 - 3,05) A | |||
EER (Nominal) (1) | W/W | 4,44 (5,17 - 4,00) A | 3,85 (5,17 - 3,50) A | 3,64 (5,97 - 3,02) A | 3,84 (4,72 - 3,02) A | 4,10 (3,93 - 3,38) A | 3,50 (3,93 - 3,04) A | 3,25 (3,93 - 2,58) A | 3,84 (5,00 - 3,02) A | 4,10 (3,93 - 3,38) A | 3,50 (3,93 - 3,04) A | 3,25 (3,93 - 2,58) A | |||
Heating capacity at -7°C (2) | kW | — | — | — | — | — | — | 12,32 | — | — | — | 12,32 | |||
Heating capacity at -15°C (2) | kW | — | — | — | — | — | — | — | — | — | — | — | |||
COP (Nominal) (1) | W/W | 4,55 (6,25 - 4,17) A | 4,03 (6,25 - 3,71) A | 4,00 (6,32 - 3,81) A | 3,85 (4,17 - 3,10) A | 4,31 (4,56 - 3,18) A | 4,02 (4,56 - 3,08) A | 3,60 (4,56 - 3,05) A | 3,85 (4,83 - 3,10) A | 4,31 (4,56 - 3,18) A | 4,02 (4,56 - 3,08) A | 3,60 (4,56 - 3,05) A | |||
External static pressure (Nominal) (5) | Pa | 70 | 70 | 70 | 70 | 100 | 100 | 100 | 70 | 100 | 100 | 100 | |||
External static pressure (Min) (5) | Pa | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |||
External static pressure (Max) (5) | Pa | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | |||
Indoor sound pressure (Hi) (6) | dB(A) | 33 | 34 | 35 | 35 | 38 | 39 | 40 | 35 | 38 | 39 | 40 | |||
Indoor sound pressure (Med) (6) | dB(A) | 29 | 30 | 32 | 32 | 34 | 35 | 36 | 32 | 34 | 35 | 36 | |||
Indoor sound pressure (Lo) (6) | dB(A) | 25 | 26 | 26 | 26 | 31 | 32 | 33 | 26 | 31 | 32 | 33 | |||
Elevation difference (in/out) (7) | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |||
Refrigerant (R410A) / CO2 Eq. | kg / T | 1,40 / 2,9232 | 1,40 / 2,9232 | 1,95 / 4,0716 | 2,35 / 4,9068 | 3,40 / 7,0992 | 3,40 / 7,0992 | 3,40 / 7,0992 | 2,35 / 4,9068 | 3,40 / 7,0992 | 3,40 / 7,0992 | 3,40 / 7,0992 |
(1) Izračun EER-a i COP-a temelji se na EN14511.
(2) Skala energetske oznake od A+++ do D. Za modele ispod 12 kW, SEER i SCOP se izračunavaju na temelju vrijednosti EU/626/2011. Za modele iznad 12 kW, SEER i SCOP se izračunavaju na temelju vrijednosti EU/2281/2016.
(3) Godišnja potrošnja energije izračunata je sukladno EU/626/2011.
(4) Kapacitet grijanja izračunava se uključujući korekciju faktora otapanja.
(5) Tvornička postavka srednjeg vanjskog statičkog tlaka.
(6) Zvučni tlak jedinica pokazuje vrijednost izmjerenu na položaju 1,5 m ispod jedinice. Zvučni tlak izmjeren je u skladu sa specifikacijom Eurovent 6/C/006-97.
(7) Prilikom postavljanja vanjske jedinice na viši položaj od unutarnje jedinice.
* Preporučeni osigurač za unutarnje 3 A.